Optimising the imaging plane for right ventricular magnetic resonance volume analysis in adult patients referred for assessment of right ventricular structure and function

被引:6
作者
Lyen, Stephen [1 ]
Mathias, Helen [1 ]
McAlindon, Elisa [1 ]
Trickey, Adam [1 ]
Rodrigues, Jonathan [1 ]
Bucciarelli-Ducci, Chiara [1 ]
Hamilton, Mark [1 ]
Manghat, Nathan [1 ]
机构
[1] Bristol Royal Infirm & Gen Hosp, Univ Hosp Bristol NHS Fdn Trust, Bristol Heart Inst, Bristol BS2 8HW, Avon, England
关键词
cardiac imaging techniques; cardiac volume; heart ventricles; magnetic resonance imaging; SHORT-AXIS; REPRODUCIBILITY; ACCURACY; IMPACT; MASS; MRI; CMR;
D O I
10.1111/1754-9485.12303
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
IntroductionOur aim was to evaluate the reproducibility and accuracy of using short-axis and axial (transaxial) plane for magnetic resonance imaging analysis in adult patients referred for assessment of right ventricular (RV) structure and function. MethodsTwenty consecutive subjects (10 male, 10 female, mean age 32.214.8 years) who were referred for RV assessment and had cardiac magnetic resonance imaging were retrospectively selected. Axial and short-axis manual contouring was performed using cine steady-state free precession sequences by three experienced imaging specialists. The reproducibility of end diastolic volumes, end systolic volumes and ejection fraction was assessed with intraclass correlation coefficients (ICCs) and paired t-tests. Left ventricular stroke volume (LVSV) and RV stroke volumes (RVSV) were compared with concordance correlation coefficients (CCCs) and t-tests to determine accuracy. ResultsThe concordance between the RVSV and LVSV was good using both methods (axial RVSV CCC=0.93, short-axis RVSV CCC=0.86). Paired t-test and analysis of variance showed that the LV/RV stroke volume differences were not significant (p=0.17). There was slight improvement in interobserver reliability with end systolic volume measurements (axial ICC=0.92, short-axis ICC=0.81) but this failed to reach statistical significance (p=0.37). There was excellent intraobserver variability (ICC>0.9). ConclusionThis study shows that there is no statistically significant difference in reproducibility or accuracy using the short-axis or axial orientations in RV volume analysis in adult patients being referred for RV assessment.
引用
收藏
页码:421 / 430
页数:10
相关论文
共 23 条
[1]   Comparison of right ventricular volume measurements between axial and short axis orientation using steady-state free precession magnetic resonance imaging [J].
Alfakih, K ;
Plein, S ;
Bloomer, T ;
Jones, T ;
Ridgway, J ;
Sivananthan, M .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 18 (01) :25-32
[2]   Cardiac Function by MRI in Congenital Heart Disease: Impact of Consensus Training on Interinstitutional Variance [J].
Beerbaum, Philipp ;
Barth, Peter ;
Kropf, Siegfried ;
Sarikouch, Samir ;
Kelter-Kloepping, Andrea ;
Franke, Diana ;
Gutberlet, Matthias ;
Kuehne, Titus .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 30 (05) :956-966
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   Prognostic importance of right ventricular dysfunction [J].
Bleasdale, RA ;
Frenneaux, MP .
HEART, 2002, 88 (04) :323-324
[5]   Assessment of the Accuracy and Reproducibility of RV Volume Measurements by CMR in Congenital Heart Disease [J].
Clarke, Christopher J. ;
Gurka, Matthew J. ;
Norton, Patrick T. ;
Kramer, Christopher M. ;
Hoyer, Andrew W. .
JACC-CARDIOVASCULAR IMAGING, 2012, 5 (01) :28-37
[6]   Comparison of Accuracy of Axial Slices Versus Short-Axis Slices for Measuring Ventricular Volumes by Cardiac Magnetic Resonance in Patients With Corrected Tetralogy of Fallot [J].
Fratz, Sohrab ;
Schuhbaeck, Annika ;
Buchner, Christine ;
Busch, Raymonde ;
Meierhofer, Christian ;
Martinoff, Stefan ;
Hess, John ;
Stern, Heiko .
AMERICAN JOURNAL OF CARDIOLOGY, 2009, 103 (12) :1764-1769
[7]   Interstudy reproducibility of right ventricular volumes, function, and mass with cardiovascular magnetic resonance [J].
Grothues, F ;
Moon, JC ;
Bellenger, NG ;
Smith, GS ;
Klein, HU ;
Pennell, DJ .
AMERICAN HEART JOURNAL, 2004, 147 (02) :218-223
[8]  
Health Research Authority, 2013, DEF RES
[9]   Anatomy, echocardiography, and normal right ventricular dimensions [J].
Ho, SY ;
Nihoyannopoulos, P .
HEART, 2006, 92 :I2-I13
[10]  
Ho SY, 2009, EUR J ECHOCARDIOGR, V10, pi3, DOI [DOI 10.1093/EJECHOCARD/JEP159, 10.1093/ejechocard/jep159]