Comparison of capsular opacification and refractive status after placement of three different intraocular lens implants following phacoemulsification and aspiration of cataracts in dogs

被引:24
作者
Gift, Barrett W. [1 ]
English, Robert V. [1 ]
Nadelstein, Brad [2 ]
Weigt, Anne K. [3 ]
Gilger, Brian C. [4 ]
机构
[1] Anim Eye Care Associates, Cary, NC USA
[2] Anim Eye Care Associates, Chesapeake, VA USA
[3] Anim Eye Care Associates, Laurel, MD USA
[4] N Carolina State Univ, Coll Vet Med, Dept Clin Sci, Raleigh, NC USA
关键词
design; dog; intraocular lens; material; posterior capsular opacification; refractive error; COLLAGEN TYPE-IV; HUMAN AUTOPSY EYES; OPTIC EDGE DESIGN; POSTERIOR CAPSULE; PHOTOGRAPHIC ASSESSMENT; SURGICAL PREVENTION; PSEUDOPHAKIC EYES; EPITHELIAL-CELLS; HAPTIC DESIGN; IN-VITRO;
D O I
10.1111/j.1463-5224.2009.00667.x
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
To evaluate the effect of lens design and biomaterial on formation of posterior capsular opacification (PCO) and refractive correction. Sixty dogs undergoing bilateral phacoemulsification for mature or diabetic cataracts. One randomly selected eye received a rounded edge 41D polymethyl-methacrylate (PMMA) intraocular replacement lens (IOL) and the contralateral eye received either a squared edge 41D hydrophilic acrylic IOL (n = 35) or a squared edge 40D hydrophobic acrylic IOL (n = 25). At the (mean = 79 day) reexamination period, PCO was graded using direct slit-lamp observation and by masked observer evaluation of digital images of the IOLs. Streak retinoscopy and B-mode ultrasound were performed at this period. The PCO score via direct slit-lamp was significantly lower for the hydrophilic acrylic IOL when compared to the PMMA IOL. Masked observer evaluation of digital images revealed that the acrylic IOLs had lower but generally not statistically significant PCO scores than the PMMA IOLs. Streak retinoscopy showed that the PMMA IOL was significantly closer to emmetropia (+0.44 D) when compared to either the hydrophilic acrylic (+0.96 D) or the hydrophobic acrylic (+1.2 D) IOLs. B-mode ultrasonography revealed the center of the hydrophilic acrylic IOL is 0.31 mm closer to the retina and the center of the hydrophobic acrylic IOL is 0.63 mm further from the retina when compared to the center of the PMMA to retina distance. Square edged foldable acrylic IOLs show a predisposition towards generating slightly less PCO than round edged PMMA IOLs in the early postoperative period, however, both acrylic IOLs had greater persistent hyperopia than the PMMA IOLs.
引用
收藏
页码:13 / 21
页数:9
相关论文
共 3 条
  • [1] Capsular tension ring alone and associated with acrylic foldable intraocular lens in posterior capsular opacification after phacoemulsification in dogs
    Morales, Adriana
    da Costa, Paula Ferreira
    da Conceicao, Luciano Fernandes
    de Andrade, Alexandre Lima
    Martinez Padua, Ivan Ricardo
    Marinho, Fabio Andrade
    da Cunha Brito, Fabio Luiz
    Lausi, Jose Luiz
    CIENCIA RURAL, 2015, 45 (03): : 540 - 545
  • [2] A comparison of posterior capsular opacification after implantation of three different hydrophobic square edge intraocular lenses
    Pai, H. Vijaya
    Pathan, Atiya
    Kamath, Yogish Subraya
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2019, 67 (09) : 1424 - 1427
  • [3] Refractive status and visual acuity changes after oil removal in eyes following phacovitrectomy, intraocular lens implantation, and silicone oil tamponade
    Song, Won Kyung
    Kim, Sung Soo
    Kim, Sung Eun
    Lee, Sung Chul
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2010, 45 (06): : 616 - 620