A microfabricated potentiometric sensor for metoclopramide determination utilizing a graphene nanocomposite transducer layer

被引:19
作者
El-Mosallamy, Sally S. [1 ]
Ahmed, Kholoud [2 ]
Daabees, Hoda G. [3 ]
Talaat, Wael [4 ]
机构
[1] Cairo Univ, Fac Pharm, Analyt Chem Dept, Cairo 11562, Egypt
[2] Fayoum Univ, Fac Pharm, Pharmaceut Analyt Chem Dept, Al Fayyum 63514, Egypt
[3] Damanhour Univ, Fac Pharm, Pharmaceut Chem Dept, Damanhour 22516, Egypt
[4] Damanhour Univ, Fac Pharm, Pharmaceut Analyt Chem Dept, Damanhour 22516, Egypt
关键词
Green analytical chemistry; Microfabrication; Copper; Solid-contact ion-selective electrode; Graphene nanocomposite; Metoclopramide; ION-SELECTIVE ELECTRODES; HPLC METHOD; ELECTROCHEMICAL SENSOR; OXIDE; METABOLITES; PYRIDOXINE; SYRUP;
D O I
10.1007/s00216-020-02884-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In the recent drug analysis arena, optimizing a green, eco-friendly, and cost-effective technique is the main target. In order to cope with green analytical chemistry principles and the trending development of miniaturized portable and handheld devices, an innovative microfabricated ion-selective electrode for the analysis of metoclopramide (MTP) was developed. The fabricated electrode adopted a two-step optimization process. The first step of optimization depended on screening different ionophores in order to enhance the sensor selectivity. Calix-4-arene showed the maximal selectivity towards MTP. The second step was utilizing a graphene nanocomposite as an ion-to-electron transducer layer between the calix-4-arene polymeric membrane and the microfabricated copper solid-contact ion-selective electrode. The graphene nanocomposite layer added more stability to electrode potential drift and short response times (10 s), probably due to the hydrophobic behavior of the graphene nanocomposite, which precludes the formation of a water layer at the Cu electrode/polymeric membrane interface. The proposed MTP sensor has been characterized according to IUPAC recommendations and the linear dynamic range estimated to be 1 x 10(-6)to 1 x 10(-2) M with LOD of 3 x 10(-7) M. The proposed sensor has been successfully employed in the selective determination of MTP in bulk powder, pharmaceutical formulation, and biological fluid. No statistical significant difference was observed upon comparing the results with those of the official method. The Eco-score of the method was assessed using the Eco-Scale tool and was compared with that of the official method.
引用
收藏
页码:7505 / 7514
页数:10
相关论文
共 51 条
[1]   Inline potentiometric monitoring of Butyrylcholinesterase activity based on metabolism of bambuterol at the point of care [J].
Abd El-Rahman, Mohamed K. ;
Eid, Sherif M. ;
Elghobashy, Mohamed R. ;
Kelani, Khadiga M. .
SENSORS AND ACTUATORS B-CHEMICAL, 2019, 285 :216-223
[2]   Design of a stable solid-contact ion-selective electrode based on polyaniline nanoparticles as ion-to-electron transducer for application in process analytical technology as a real-time analyzer [J].
Abd El-Rahman, Mohamed K. ;
Rezk, Mamdouh R. ;
Mahmoud, Amr M. ;
Elghobashy, Mohamed R. .
SENSORS AND ACTUATORS B-CHEMICAL, 2015, 208 :14-21
[3]   Improved determination of tramadol hydrochloride in biological fluids and pharmaceutical preparations utilizing a modified carbon paste electrode [J].
Abu-Shawish, Hazem M. ;
Abu Ghalwa, Nasser ;
Zaggout, Faried R. ;
Saadeh, Salman M. ;
Al-Dalou, Ayoub R. ;
Abou Assi, Anwar A. .
BIOCHEMICAL ENGINEERING JOURNAL, 2010, 48 (02) :237-245
[4]  
AlHaideri A-MA, 2012, IRAQI J PHARM SCI, V21, P70
[5]  
[Anonymous], 2017, BRIT PHARM
[6]   Potentiometric sensors for trace-level analysis [J].
Bakker, E ;
Pretsch, E .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2005, 24 (03) :199-207
[7]   RECOMMENDATIONS FOR NOMENCLATURE OF ION-SELECTIVE ELECTRODES - (IUPAC RECOMMENDATIONS 1994) [J].
BUCK, RP ;
LINDNER, E .
PURE AND APPLIED CHEMISTRY, 1994, 66 (12) :2527-2536
[8]   Cyclodextrin-Drug Inclusion Complexes: In Vivo and In Vitro Approaches [J].
Carneiro, Simone Braga ;
Costa Duarte, Fernanda Ilary ;
Heimfarth, Luana ;
Siqueira Quintans, Jullyana de Souza ;
Quintans-Junior, Lucindo Jose ;
da Veiga Junior, Valdir Florencio ;
Neves de Lima, Adley Antonini .
INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2019, 20 (03)
[9]   Evidence of a water layer in solid-contact polymeric ion sensors [J].
De Marco, Roland ;
Veder, Jean-Pierre ;
Clarke, Graeme ;
Nelson, Andrew ;
Prince, Kathryn ;
Pretsch, Erno ;
Bakker, Eric .
PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2008, 10 (01) :73-76
[10]  
de Namor AFD, 1998, CHEM REV, V98, P2495