A new fabrication technique of CdTe strip detectors for gamma-ray imaging and spectroscopy

被引:0
|
作者
Niraula, M
Nakamura, A
Aoki, T
Tomita, Y
Hatanaka, Y
机构
[1] Shizuoka Univ, Res Inst Elect, Hamamatsu, Shizuoka 4328011, Japan
[2] Hamamatsu Photon KK, Elect Tube R&D Ctr, Shizuoka, Japan
来源
PHYSICA STATUS SOLIDI B-BASIC SOLID STATE PHYSICS | 2002年 / 229卷 / 02期
关键词
D O I
10.1002/1521-3951(200201)229:2<1103::AID-PSSB1103>3.3.CO;2-2
中图分类号
O469 [凝聚态物理学];
学科分类号
070205 ;
摘要
Diode type CdTe strip detectors were fabricated in a new and simple technique for imaging and spectroscopy applications. On a high resistivity p-like single crystal CdTe water, n-type strips were formed by evaporating a thin indium layer on the crystal through a metallic shadow mask and then diffusing it inside the crystal by irradiating with an excimer laser. On the opposite side of the crystal a gold electrode was evaporated on the whole surface. The current-voltage characteristics of the detectors exhibited diode-like property with a low value of reverse bias leakage current from the individual strips. The spectral response from all strips was very good and uniform with typical energy resolutions of 2.5 keV and 3.6 keV FWHM at 59.5 keV peak of Am-241 and 122 keV peak of Co-57 radioisotopes, respectively for radiation detection tests performed at room temperature. Details about the detector fabrication and the spectral results that demonstrate the imaging and spectroscopy capabilities of these detectors are presented.
引用
收藏
页码:1103 / 1107
页数:5
相关论文
共 50 条
  • [11] CdTe and CdZnTe X-ray and gamma-ray detectors for imaging systems
    Eisen, Y
    Shor, A
    Mardor, I
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 3311 - 3319
  • [12] CdTe stacked detectors for gamma-ray detection
    Watanabe, S
    Takahashi, T
    Okada, Y
    Sato, G
    Kouda, M
    Mitani, T
    Kobayashi, Y
    Nakazawa, K
    Kuroda, Y
    Onishi, M
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 2434 - 2438
  • [13] New perspectives in gamma-ray imaging with CdZnTe/CdTe
    Verger, L
    Drezet, A
    d'Aillon, EG
    Mestais, C
    Montémont, G
    Dierre, F
    Peyret, O
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2313 - 2319
  • [14] CdTe stacked detectors for gamma-ray detection
    Watanabe, S
    Takahashi, T
    Okada, Y
    Sato, G
    Kouda, M
    Mitani, T
    Kobayashi, Y
    Nakazawa, K
    Kuroda, Y
    Onishi, M
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (03) : 1292 - 1296
  • [15] IMPROVEMENTS IN MANUFACTURE OF CDTE GAMMA-RAY DETECTORS
    BRELANT, S
    ELLIOTT, M
    ENTINE, G
    HSU, S
    REVUE DE PHYSIQUE APPLIQUEE, 1977, 12 (02): : 141 - 146
  • [16] Development of Double-Sided CdTe Strip Detectors for γ-Ray Imaging and Spectroscopy
    Ishikawa, Shin-nosuke
    Watanabe, Shin
    Fukuyama, Taro
    Sato, Goro
    Kokubun, Motohide
    Odaka, Hirokazu
    Saito, Shinya
    Takahashi, Tadayuki
    Nakazawa, Kazuhiro
    Tanaka, Takaaki
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2010, 49 (11)
  • [17] Pixellated thallium bromide detectors for gamma-ray spectroscopy and imaging
    Onodera, T
    Hitomi, K
    Shoji, T
    Hiratate, Y
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 525 (1-2): : 199 - 204
  • [18] New developments in CdTe and CdZnTe detectors for x and gamma-ray applications
    Veger, L
    Bonnefoy, JP
    Glasser, F
    OuvrierBuffet, P
    JOURNAL OF ELECTRONIC MATERIALS, 1997, 26 (06) : 738 - 744
  • [19] CRYSTAL-GROWTH OF CDTE FOR GAMMA-RAY DETECTORS
    WALD, FV
    ENTINE, G
    NUCLEAR INSTRUMENTS & METHODS, 1978, 150 (01): : 13 - 23
  • [20] CONTACTS ON CHEMICALLY ETCHED CDTE GAMMA-RAY DETECTORS
    MUSA, A
    PONPON, JP
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 216 (1-2): : 259 - 263