Wooden beam ends in combination with interior insulation: An experimental study on the impact of convective moisture transport

被引:30
作者
Vereecken, Evy [1 ]
Roels, Staf [1 ]
机构
[1] Katholieke Univ Leuven, Dept Civil Engn, Bldg Phys Sect, Kasteelpk Arenberg 40, B-3001 Leuven, Belgium
基金
欧盟地平线“2020”;
关键词
Wooden beam ends; Interior insulation; Airtight sealing; Convective moisture transport; Capillary active insulation; Hygrothermal assessment; MASONRY WALLS; HYGROTHERMAL BEHAVIOR; INTERNAL INSULATION; THERMAL INSULATION; BUILDING STOCK; ENERGY SAVINGS; RISK; PERFORMANCE; SYSTEMS; EMISSIONS;
D O I
10.1016/j.buildenv.2018.10.060
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The risk free applicability of interior insulation in the presence of wooden beam ends is still a point of discussion. Two phenomena enlarge the risk on wood decay when interior insulation is applied: (1) a higher moisture load in the masonry due to a reduced drying potential and (2) a lower temperature in the masonry resulting in a higher risk on condensation if exfiltration of moist indoor air occurs. This paper studies - based on a hot box-cold box experiment - the impact of convective moisture transport and this for two vapour tight and one capillary active vapour open interior insulation system applied to a masonry wall with an embedded wooden beam. A comparison is made to a non-insulated wall. No wind-driven rain is included, making a pure analysis of convective moisture transport possible. For non-sealed beam junctions, a significant increase in relative humidity due to moist indoor air reaching the colder beam surface was clearly visible. The impact of air exfiltration was most pronounced for the capillary active system and was influenced by the way of sealing the airgap between the beam end and the wall. It is recommended to avoid air exfiltration as well as air circulation near the beam end. For mineral wool, the importance of an airtight sealing was less pronounced. An overpressure was found to influence the hygrothermal conditions near the beam ends of the poorly sealed test setups. Additionally, the convective air flow near the beam ends was analysed based on the measured temperatures.
引用
收藏
页码:524 / 534
页数:11
相关论文
共 46 条
[1]  
[Anonymous], 2018, LIND LEAK TEST
[2]   European residential buildings and empirical assessment of the Hellenic building stock, energy consumption, emissions and potential energy savings [J].
Balaras, Constantinos A. ;
Gaglia, Athina G. ;
Georgopoulou, Elena ;
Mirasgedis, Sevastianos ;
Sarafidis, Yiannis ;
Lalas, Dimitris P. .
BUILDING AND ENVIRONMENT, 2007, 42 (03) :1298-1314
[3]   A concept of capillary active, dynamic insulation integrated with heating, cooling and ventilation, air conditioning system [J].
Bomberg M. .
Frontiers of Architecture and Civil Engineering in China, 2010, 4 (4) :431-437
[4]  
Carll CG, 1999, J TEST EVAL, V27, P150
[5]   Methods to determine wood moisture content and their applicability in monitoring concepts [J].
Dietsch, Philipp ;
Franke, Steffen ;
Franke, Bettina ;
Gamper, Andreas ;
Winter, Stefan .
JOURNAL OF CIVIL STRUCTURAL HEALTH MONITORING, 2015, 5 (02) :115-127
[6]   Risk analysis of biodeterioration of wooden beams embedded in internally insulated masonry walls [J].
Guizzardi, M. ;
Carmeliet, J. ;
Derome, D. .
CONSTRUCTION AND BUILDING MATERIALS, 2015, 99 :159-168
[7]   Hygrothermal behavior of a massive wall with interior insulation during wetting [J].
Guizzardi, M. ;
Derome, D. ;
Vonbank, R. ;
Carmeliet, J. .
BUILDING AND ENVIRONMENT, 2015, 89 :59-71
[8]   Hygrothermal assessment of internally added thermal insulation on external brick walls in Swedish multifamily buildings [J].
Hamid, Akram Abdul ;
Wallenten, Petter .
BUILDING AND ENVIRONMENT, 2017, 123 :351-362
[9]   Internal insulation applied in heritage multi-storey buildings with wooden beams embedded in solid masonry brick facades [J].
Harrestrup, M. ;
Svendsen, S. .
BUILDING AND ENVIRONMENT, 2016, 99 :59-72
[10]   Full-scale test of an old heritage multi-storey building undergoing energy retrofitting with focus on internal insulation and moisture [J].
Harrestrup, M. ;
Svendsen, S. .
BUILDING AND ENVIRONMENT, 2015, 85 :123-133