Accuracy of the raw-data-based effective atomic numbers and monochromatic CT numbers for contrast medium with a dual-energy CT technique

被引:13
作者
Kawahara, Daisuke [1 ,2 ]
Ozawa, Shuichi [3 ,4 ]
Yokomachi, Kazushi [1 ]
Tanaka, Sodai [5 ]
Higaki, Toru [6 ,7 ]
Fujioka, Chikako [1 ]
Suzuki, Tatsuhiko [2 ]
Tsuneda, Masato [2 ]
Nakashima, Takeo [1 ]
Ohno, Yoshimi [1 ]
Nagata, Yasushi [3 ,4 ]
机构
[1] Hiroshima Univ Hosp, Div Clin Support, Radiat Therapy Sect, Hiroshima, Japan
[2] Hiroshima Univ, Grad Sch Biomed & Hlth Sci, Med & Dent Sci Course, Hiroshima, Japan
[3] Hiroshima Univ, Inst Biomed & Hlth Sci, Dept Radiat Oncol, Hiroshima, Japan
[4] Hiroshima High Precis Radiotherapy Canc Ctr, Hiroshima, Japan
[5] Univ Tokyo, Sch Engn, Dept Nucl Engn & Management, Tokyo, Japan
[6] Hiroshima Univ, Dept Diagnost Radiol, Hiroshima, Japan
[7] Hiroshima Univ, Dept Radiol, Hiroshima, Japan
关键词
COMPUTED-TOMOGRAPHY; INITIAL-EXPERIENCE; DIFFERENTIATION; ANGIOGRAPHY;
D O I
10.1259/bjr.20170524
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To evaluate the accuracy of raw-data-based effective atomic number (Z(eff)) values and monochromatic CT numbers for contrast material of varying iodine concentrations, obtained using dual-energy CT. Methods: We used a tissue characterization phantom and varying concentrations of iodinated contrast medium. A comparison between the theoretical values of Z(eff) and that provided by the manufacturer was performed. The measured and theoretical monochromatic CT numbers at 40-130 keV were compared. Results: The average difference between the Z(eff) values of lung (inhale) inserts in the tissue characterization phantom was 81.3% and the average Z(eff) difference was within 8.4%. The average difference between the Z(eff) values of the varying concentrations of iodinated contrast medium was within 11.2%. For the varying concentrations of iodinated contrast medium, the differences between the measured and theoretical monochromatic CT values increased with decreasing monochromatic energy. The Z(eff) and monochromatic CT numbers in the tissue characterization phantom were reasonably accurate. Conclusion: The accuracy of the raw-data-based Z(eff) values was higher than that of image-based Zeff values in the tissue-equivalent phantom. The accuracy of Z(eff) values in the contrast medium was in good agreement within the maximum SD found in the iodine concentration range of clinical dynamic CT imaging. Moreover, the optimum monochromatic energy for human tissue and iodinated contrast medium was found to be 70 keV.
引用
收藏
页数:5
相关论文
共 18 条
[1]   ENERGY-SELECTIVE RECONSTRUCTIONS IN X-RAY COMPUTERIZED TOMOGRAPHY [J].
ALVAREZ, RE ;
MACOVSKI, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1976, 21 (05) :733-744
[2]   Intravenous Contrast Medium Administration and Scan Timing at CT: Considerations and Approaches [J].
Bae, Kyongtae T. .
RADIOLOGY, 2010, 256 (01) :32-61
[3]   Iodine Quantification With Dual-Energy CT: Phantom Study and Preliminary Experience With Renal Masses [J].
Chandarana, Hersh ;
Megibow, Alec J. ;
Cohen, Benjamin A. ;
Srinivasan, Ramya ;
Kim, Danny ;
Leidecker, Christianne ;
Macari, Michael .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 196 (06) :W693-W700
[4]   Dual-Energy CT: Oncologic Applications [J].
De Cecco, Carlo Nicola ;
Darnell, Anna ;
Rengo, Marco ;
Muscogiuri, Giuseppe ;
Bellini, Davide ;
Ayuso, Carmen ;
Laghi, Andrea .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (05) :S98-S105
[5]   SPLIT XENON DETECTOR FOR TOMOCHEMISTRY IN COMPUTED TOMOGRAPHY [J].
FENSTER, A .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1978, 2 (03) :243-252
[6]   Accuracies of the synthesized monochromatic CT numbers and effective atomic numbers obtained with a rapid kVp switching dual energy CT scanner [J].
Goodsitt, Mitchell M. ;
Christodoulou, Emmanuel G. ;
Larson, Sandra C. .
MEDICAL PHYSICS, 2011, 38 (04) :2222-2232
[7]   Dual-Energy CT Applications in the Abdomen [J].
Heye, Tobias ;
Nelson, Rendon C. ;
Ho, Lisa M. ;
Marin, Daniele ;
Boll, Daniel T. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (05) :S64-S70
[8]   Material differentiation by dual energy CT: initial experience [J].
Johnson, Thorsten R. C. ;
Krauss, Bernhard ;
Sedlmair, Martin ;
Grasruck, Michael ;
Bruder, Herbert ;
Morhard, Dominik ;
Fink, Christian ;
Weckbach, Sabine ;
Lenhard, Miriam ;
Schmidt, Bernhard ;
Flohr, Thomas ;
Reiser, Maximilian F. ;
Becker, Christoph R. .
EUROPEAN RADIOLOGY, 2007, 17 (06) :1510-1517
[9]   Dual-Energy Computed Tomography Angiography of the Head and Neck With Single-Source Computed Tomography: A New Technical (Split Filter) Approach for Bone Removal [J].
Kaemmerer, Nadine ;
Brand, Michael ;
Hammon, Matthias ;
May, Matthias ;
Wuest, Wolfgang ;
Krauss, Bernhard ;
Uder, Michael ;
Lell, Michael M. .
INVESTIGATIVE RADIOLOGY, 2016, 51 (10) :618-623
[10]   Dual-Energy CT: Clinical Applications in Various Pulmonary Diseases [J].
Kang, Mi-Jin ;
Park, Chang Min ;
Lee, Chang-Hyun ;
Goo, Jin Mo ;
Lee, Hyun Ju .
RADIOGRAPHICS, 2010, 30 (03) :685-698