Influence of Various Voltage Leads on AC Loss Measurement in a Double Layer BSCCO Conductor

被引:7
|
作者
Ryu, K. [1 ]
Li, Z. Y. [2 ]
Ma, Y. H. [3 ]
Hwang, S. D. [4 ]
机构
[1] Chonnam Natl Univ, Dept Elect Engn, Kwangju 500757, South Korea
[2] Chonnam Natl Univ, Kwangju, South Korea
[3] Jiangnan Univ, Sch IoT, Dept Elect Engn, Wuxi 214122, Peoples R China
[4] Korea Elect Power Res Inst, Taejon 305380, South Korea
关键词
AC loss measurement; contactless lead; double layer conductor; outer-lead; total-lead; TAPES;
D O I
10.1109/TASC.2012.2232957
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We have operated the two 22.9 kV/50 MVA HTS cable systems installed at Gochang Test Yard and Icheon Substation of Korea Electric Power Corporation (KEPCO), respectively; they have a double layer conductor and a single layer shield, consisting of BSCCO and YBCO-NiW wires. In general, the ac loss of a multilayer cylindrical conductor like the KEPCO HTS cables is evaluated from the conductor's current and the loss voltage of a lead soldered onto its outermost layer. To experimentally investigate what the voltage lead on the outermost layer picks up in this study, we prepared a double layer BSCCO conductor sample, and attached the four voltage leads of the outer, inner, contactless, and total leads. Then its ac loss for these leads was examined for different layer current distribution, and finally compared with a numerically calculated one. The results show that the outer-lead, which is often used in the double layer conductors, takes only the outer layer's loss voltage like the contactless-lead. Therefore, for ac loss evaluation of our double layer sample, a new voltage lead, total-lead, is presented besides the conventionally used outer-lead. The total-lead best fits with the numerical calculations, regardless of layer current distribution. However, the outer-lead is not suitable, especially for nonuniform distribution, although it still now is valid only for uniform distribution.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] AC losses for the various voltage-leads in a semi-triple layer BSCCO conductor
    Li, Z.
    Ryu, K.
    Hwang, S. D.
    Cha, G.
    Song, H. J.
    PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS, 2011, 471 (21-22): : 1554 - 1558
  • [2] A Numerical Study on AC Losses of a Double Layer Polygonal BSCCO Conductor by Finite Element Method
    Xu, J.
    Li, Z. Y.
    Ryu, K.
    Hwang, S. D.
    Jin, Z.
    Hong, Z.
    JOURNAL OF SUPERCONDUCTIVITY AND NOVEL MAGNETISM, 2014, 27 (08) : 1831 - 1836
  • [3] A Numerical Study on AC Losses of a Double Layer Polygonal BSCCO Conductor by Finite Element Method
    J. Xu
    Z. Y. Li
    K. Ryu
    S. D. Hwang
    Z. Jin
    Z. Hong
    Journal of Superconductivity and Novel Magnetism, 2014, 27 : 1831 - 1836
  • [4] AC LOSS MEASUREMENT OF THE SMES/CIC CONDUCTOR
    VANSCIVER, SW
    BARTHOLOMEW, K
    OLIVA, AB
    WELTON, S
    CRYOGENICS, 1994, 34 : 615 - 618
  • [5] AC-loss measurements on HTSC cable conductor with transposed BSCCO-tapes
    Rasmussen, C
    Olsen, SK
    APPLIED SUPERCONDUCTIVITY 1997, VOLS 1 AND 2: VOL 1: SMALL SCALE AND ELECTRONIC APPLICATIONS; VOL 2: LARGE SCALE AND POWER APPLICATIONS, 1997, (158): : 1441 - 1444
  • [6] Modelling and measurement of ac loss in BSCCO/Ag-tape windings
    Oomen, MP
    Nanke, R
    Leghissa, M
    SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 2003, 16 (03): : 339 - 354
  • [7] Influence of Transport Current Distribution on AC Transport Current Loss Measurement in an Assembled Conductor
    Ogawa, Jun
    Fukui, Satoshi
    Oka, Tetsuo
    Sato, Takao
    Shinkai, Kazuya
    Koyama, Takashi
    Ito, Takahiro
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2010, 20 (03) : 1296 - 1299
  • [8] AC Loss Measurement of an HTS Cable Model With a Shield Through Virtual and Contactless Voltage Leads
    Ryu, Kyung-woo
    Li, Zhuyong
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2016, 26 (06)
  • [9] Analysis and measurement of AC transport current loss in BSCCO tape in external magnetic field
    Fukui, S
    Ikeda, M
    Sano, T
    Sango, H
    Yamaguchi, M
    Takao, T
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2001, 11 (01) : 2212 - 2215
  • [10] Experimental investigation on the influence of AC voltage on positive corona current pulses from DC conductor parallel with AC conductor
    Li, Yinfei
    Li, Xuebao
    Zhang, Qian
    Lu, Tiebing
    2018 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (IEEE CEIDP), 2018, : 457 - 460