Reduced graphene oxide-based field effect transistors for the detection of E7 protein of human papillomavirus in saliva

被引:84
作者
Aspermair, Patrik [1 ,2 ,3 ]
Mishyn, Vladyslav [1 ]
Bintinger, Johannes [3 ]
Happy, Henri [1 ]
Bagga, Komal [4 ]
Subramanian, Palaniappan [5 ]
Knoll, Wolfgang [2 ,3 ]
Boukherroub, Rabah [1 ]
Szunerits, Sabine [1 ]
机构
[1] Univ Lille, CNRS, Cent Lille, Univ Polytech Hauts de France,UMR 8520,IEMN, F-59000 Lille, France
[2] CEST Competence Ctr Electrochem Surface Technol, Konrad Lorenz Str 24, A-3430 Tulln, Austria
[3] Austrian Inst Technol, Biosensor Technol, Konrad Lorenz Str 24, A-3430 Tulln, Austria
[4] Dublin City Univ, Sch Mech & Mfg Engn, Adv Proc Technol Res Ctr, Dublin 9, Ireland
[5] Katholieke Univ Leuven, Dept Mat Engn, Kateelpk, B-3001 Heverlee, Belgium
关键词
Human papillomavirus (HPV); Aptamer; Reduced graphene oxide (rGO); Field effect transistors; Surface functionalization; Electronic biosensor; Point-of-care diagnostics; VIRAL DETECTION; BIOSENSOR; MOBILITY; APTAMER; PCR;
D O I
10.1007/s00216-020-02879-z
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Several challenging biological sensing concepts have been realized using electrolyte-gated reduced graphene oxide field effect transistors (rGO-FETs). In this work, we demonstrate the interest of rGO-FET for the sensing of human papillomavirus (HPV), one of the most common sexually transmitted viruses and a necessary factor for cervical carcinogenesis. The highly sensitive and selective detection of the HPV-16 E7 protein relies on the attractive semiconducting characteristics of pyrene-modified rGO functionalized with RNA aptamer Sc5-c3. The aptamer-functionalized rGO-FET allows for monitoring the aptamer-HPV-16 E7 protein binding in real time with a detection limit of about 100 pg mL(-1)(1.75 nM) for HPV-16 E7 from five blank noise signals (95% confidence level). The feasibility of this method for clinical application in point-of-care technology is evaluated using HPV-16 E7 protein suspended in saliva and demonstrates the successful fabrication of a promising field effect transistor biosensor for HPV diagnosis. Graphical abstract
引用
收藏
页码:779 / 787
页数:9
相关论文
共 50 条
  • [31] Non-invasive oral cancer detection from saliva using zinc oxide-reduced graphene oxide nanocomposite based bioelectrode
    Verma, Shilpi
    Singh, Surinder P.
    MRS COMMUNICATIONS, 2019, 9 (04) : 1227 - 1234
  • [32] The layer-by-layer assembly of reduced graphene oxide films and their application as solution-gated field-effect transistors
    dos Santos, Fabricio A.
    Vieira, Nirton C. S.
    Zambianco, Naiara A.
    Janegitz, Bruno C.
    Zucolotto, Valtencir
    APPLIED SURFACE SCIENCE, 2021, 543
  • [33] Potato Virus X Coat Protein Fusion to Human Papillomavirus 16 E7 Oncoprotein Enhance Antigen Stability and Accumulation in Tobacco Chloroplast
    Morgenfeld, Mauro
    Eugenia Segretin, Maria
    Wirth, Sonia
    Lentz, Ezequiel
    Zelada, Alicia
    Mentaberry, Alejandro
    Gissmann, Lutz
    Bravo-Almonacid, Fernando
    MOLECULAR BIOTECHNOLOGY, 2009, 43 (03) : 243 - 249
  • [34] Potato Virus X Coat Protein Fusion to Human Papillomavirus 16 E7 Oncoprotein Enhance Antigen Stability and Accumulation in Tobacco Chloroplast
    Mauro Morgenfeld
    María Eugenia Segretin
    Sonia Wirth
    Ezequiel Lentz
    Alicia Zelada
    Alejandro Mentaberry
    Lutz Gissmann
    Fernando Bravo-Almonacid
    Molecular Biotechnology, 2009, 43 : 243 - 249
  • [35] High Response Photodetection by Applying the Optimized Photoreceptor Protein Modification on Graphene Based Field Effect Transistors
    Tong, Jing
    Zhang, Lei
    Wang, Yi
    Li, Tie
    FRONTIERS IN MATERIALS, 2020, 7
  • [36] Development and validation of a multiplex reverse transcript real-time PCR for E6/E7 mRNA detection of high-risk human papillomavirus
    Pan, Caixia
    Zhou, Jing
    Lyu, Jiangfeng
    Ren, Xuyi
    JOURNAL OF MEDICAL MICROBIOLOGY, 2018, 67 (10) : 1509 - 1514
  • [37] Detection of Matrilysin Activity Using Polypeptide Functionalized Reduced Graphene Oxide Field-Effect Transistor Sensor
    Chen, Hu
    Chen, Peng
    Huang, Jingfeng
    Selegard, Robert
    Platt, Mark
    Palaniappan, Alagappan
    Aili, Daniel
    Tok, Alfred Iing Yoong
    Liedberg, Bo
    ANALYTICAL CHEMISTRY, 2016, 88 (06) : 2994 - 2998
  • [38] Creatinine-induced specific signal responses and enzymeless ratiometric electrochemical detection based on copper nanoparticles electrodeposited on reduced graphene oxide-based hybrids
    Gao, Xiaohui
    Gui, Rijun
    Guo, Huijun
    Wang, Zonghua
    Liu, Qingyun
    SENSORS AND ACTUATORS B-CHEMICAL, 2019, 285 : 201 - 208
  • [39] Air-Stable Symmetric Ambipolar Field-Effect Transistors Based on Reduced Graphene Oxide-OTS Self-Assembled Monolayer Heterostructure
    Peng, Peng
    Liu, Hongtao
    Wu, Bin
    Tang, Qingxin
    Liu, Yunqi
    CHEMNANOMAT, 2019, 5 (04): : 472 - 478
  • [40] Channel-Length-Dependent Field-Effect Mobility and Carrier Concentration of Reduced Graphene Oxide Thin-Film Transistors
    Kobayashi, Toshiyuki
    Kimura, Nozomi
    Chi, Junbin
    Hirata, Shintaro
    Hobara, Daisuke
    SMALL, 2010, 6 (11) : 1210 - 1215