An innovative strategy to treat large metaphyseal segmental femoral bone defect using customized design and 3D printed micro-porous prosthesis: a prospective clinical study

被引:25
作者
Hou, Guojin [1 ,2 ]
Liu, Bingchuan [1 ,2 ]
Tian, Yun [1 ,2 ]
Liu, Zhongjun [1 ,2 ]
Zhou, Fang [1 ,2 ]
Ji, Hongquan [1 ,2 ]
Zhang, Zhishan [1 ,2 ]
Guo, Yan [1 ,2 ]
Lv, Yang [1 ,2 ]
Yang, Zhongwei [1 ,2 ]
Wen, Peng [3 ]
Zheng, Yufeng [4 ]
Cheng, Yan [4 ]
机构
[1] Peking Univ, Dept Orthopaed Surg, Hosp 3, 49 North Garden Rd, Beijing 100191, Peoples R China
[2] Peking Univ, Engn Res Ctr Bone & Joint Precis Med, Hosp 3, Minist Educ, 49 North Garden Rd, Beijing 100191, Peoples R China
[3] Tsinghua Univ, Beijing 100084, Peoples R China
[4] Peking Univ, Beijing 100871, Peoples R China
关键词
TITANIUM MESH CAGE; IN-VIVO; IMPLANTS; RECONSTRUCTION; MANAGEMENT; SCAFFOLDS; INGROWTH; SURGERY; MODEL; SIZE;
D O I
10.1007/s10856-020-06406-5
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Five patients with segmental irregular-shaped bone defect of the femur were recruited in this study from 2017.12 to 2018.11. All patients were treated by customized design and 3D printed micro-porous prosthesis. And the procedure was divided into stages: radical debridement and temporary fixation (the first stage); the membrane formation and virtual surgery (intervening period for 6-8 weeks); definite reconstruction the defects (the second stage). Routine clinical follow-up and radiographic evaluation were done to assess bone incorporation and complications of internal fixation. The weight-bearing time and the joint function of the patients were recorded. The patients were followed up for an average of 16.4 months. The average length of bone defect and the distal residual bone was 12 cm and 6.5 cm. The average time of partial weight-bearing and full weight-bearing was 12.7 days and 2.6 months. X-ray demonstrated good osseous integration of the implant/bone interface. No complications occurred such as implant loosening, subsidence, loss of correction and infection. At the last follow-up, Harris score of hip joint was excellent in 2 cases, good in 2 cases, fair in 1 case; HSS score of knee joint was good in 4 cases, middle in 1 case. From our study, we concluded that meticulous customized design 3D printed micro-porous prosthesis combined with intramedullary nail may be a promising and an alternative strategy to treat metaphyseal segmental irregular-shaped femoral bone defect, especially for cases with massive juxta-articular bone loss.
引用
收藏
页数:9
相关论文
共 30 条
  • [1] Surgical management of a long segmental defect of the humerus using a cylindrical titanium mesh cage and plates - A case report
    Attias, N
    Lehman, RE
    Bodell, LS
    Lindsey, RW
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2005, 19 (03) : 211 - 216
  • [2] Three-Dimensional Computed Tomography-Based Modeling of Sagittal Cadaveric Femoral Bowing and Implications for Intramedullary Nailing
    Buford, William L., Jr.
    Turnbow, Benjamin J.
    Gugala, Zbigniew
    Lindsey, Ronald W.
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2014, 28 (01) : 10 - 16
  • [3] Cao JM, 2016, J PRACT ORTHOP, V22, P980
  • [4] The cylindrical titanium mesh cage for treatment of a long bone segmental defect: Description of a new technique and report of two cases
    Cobos, JA
    Lindsey, RW
    Gugala, Z
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2000, 14 (01) : 54 - 59
  • [5] Design and properties of 3D scaffolds for bone tissue engineering
    Gomez, S.
    Vlad, M. D.
    Lopez, J.
    Fernandez, E.
    [J]. ACTA BIOMATERIALIA, 2016, 42 : 341 - 350
  • [6] Gouin Francois, 2014, Sarcoma, V2014, P842709, DOI 10.1155/2014/842709
  • [7] Osteoclasts and their precursors are present in the induced-membrane during bone reconstruction using the Masquelet technique
    Gouron, Richard
    Petit, Laurent
    Boudot, Cedric
    Six, Isabelle
    Brazier, Michel
    Kamel, Said
    Mentaverri, Romuald
    [J]. JOURNAL OF TISSUE ENGINEERING AND REGENERATIVE MEDICINE, 2017, 11 (02) : 382 - 389
  • [8] Use of 3D Printing in Complex Spinal Surgery: Historical Perspectives, Current Usage, and Future Directions
    Grant, Caroline A.
    Izatt, Maree T.
    Labrom, Robert D.
    Askin, Geoffrey N.
    Glatt, Vaida
    [J]. TECHNIQUES IN ORTHOPAEDICS, 2016, 31 (03) : 172 - 180
  • [9] Genomewide Molecular and Biologic Characterization of Biomembrane Formation Adjacent to a Methacrylate Spacer in the Rat Femoral Segmental Defect Model
    Gruber, Helen E.
    Gettys, Franklin K.
    Montijo, Harvey E.
    Starman, James S.
    Bayoumi, Essraa
    Nelson, Kenneth J.
    Hoelscher, Gretchen L.
    Ramp, Warren K.
    Zinchenko, Natalia
    Ingram, Jane A.
    Bosse, Michael J.
    Kellam, James F.
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2013, 27 (05) : 290 - 297
  • [10] Salvage of Severe Foot and Ankle Trauma With a 3D Printed Scaffold
    Hamid, Kamran S.
    Parekh, Selene G.
    Adams, Samuel B.
    [J]. FOOT & ANKLE INTERNATIONAL, 2016, 37 (04) : 433 - 439