Calculation of lightning flashovers and backflash level on 230kV transmission lines

被引:0
|
作者
Al-Qahtani, BJ [1 ]
Shwehdi, MH [1 ]
机构
[1] SAOO, NGPD, TSU, Abqaiq, Saudi Arabia
关键词
lightning flashovers; backflashovers; simulation and ground wires;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Lightning has been one of the important problems for insulation design of power systems and it is still the main cause of outages of transmission and distribution lines. Lightning caused outages can be reduced by lightning protection devices such as ground wires and lightning arresters. This paper presents a comparative studies used to determine the lightning backflashovers level on 230kV transmission lines utilized by Saudi Electric Company (SEC) in Saudi Arabia, using two well known approaches CIGRE, and the simplified method. The studies include lightning flashovers, backflash analysis, as dependent on the tower design parameters which is considered the main parameters that reduce the rate of lightning bachflashovers in the transmission lines. The study results can be applied to reduce the number lightning flashovers and therefore reduce the transmission lines outages.
引用
收藏
页码:90 / 95
页数:6
相关论文
共 50 条
  • [1] Calculation of lightning failures rate level on 230kv transmission lines
    Al-Qahtani, BJ
    Shwehdi, MH
    OVERVOLTAGES IN POWER, ELECTRONIC, COMPUTER AND ENGINEERING, 2005, : 69 - 74
  • [2] Computation of Lightning Flashovers & Backflashover Voltage Levels on 230KV Transmission Lines
    Shwehdi, M. H.
    2008 IEEE 2ND INTERNATIONAL POWER AND ENERGY CONFERENCE: PECON, VOLS 1-3, 2008, : 1488 - 1493
  • [3] Lightning Backflash Performance for ±500kV Double Circuit Transmission Lines
    Lu, Hailiang
    Wen, Xishan
    Zhang, Chengwei
    Tong, Xuefang
    2009 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), VOLS 1-7, 2009, : 3535 - +
  • [4] Best Practices for the Design of 115KV to 230KV Overhead Transmission Lines
    Kempner, L., Jr.
    Haldar, A.
    ELECTRICAL TRANSMISSION AND SUBSTATION STRUCTURES 2015: TECHNICAL CHALLENGES AND INNOVATIVE SOLUTIONS IN GRID MODERNIZATION, 2015, : 178 - 189
  • [5] Study of lightning overvoltages in Valcor-Guanta II 230kV overhead transmission line
    Martinez, V. M.
    Uzcategui, E. A.
    Jimenez, P. R.
    2006 IEEE/PES TRANSMISSION & DISTRIBUTION CONFERENCE & EXPOSITION: LATIN AMERICA, VOLS 1-3, 2006, : 1126 - +
  • [6] Optimal Selection and Arrangement of Cables for Compact Overhead Transmission Lines of 138/230kV
    Vasconcelos, J. A.
    Teixeira, D. A.
    Ribeiro, M. F. O.
    IEEE LATIN AMERICA TRANSACTIONS, 2017, 15 (08) : 1460 - 1466
  • [7] Parameters Affecting Lightning Backflash Over Pattern at 132kV Double Circuit Transmission Lines
    Abu Talib, Dian Najihah
    Abu Bakar, Ab. Halim
    Mokhlis, Hazlie
    2012 IEEE INTERNATIONAL CONFERENCE ON POWER AND ENERGY (PECON), 2012, : 808 - 812
  • [8] Lightning fault rate calculation of transmission lines taking statistical variation of arching-horn flashovers into account
    Itamoto N.
    Kawamura H.
    Shinjo K.
    Tanaka Y.
    Noda T.
    IEEJ Transactions on Power and Energy, 2020, 140 (02) : 126 - 133
  • [9] Statistics and Analysis of Lightning Flashovers of Transmission Lines during 2000∼2007
    Li Xiaolan
    Chen Jiahong
    Gu Shanqiang
    Tong Xuefang
    ICHVE 2008: 2008 INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION, 2008, : 53 - 55
  • [10] Statistics and analysis of lightning flashovers of transmission lines during 2000~2007
    Li, Xiao-Lan
    Chen, Jia-Hong
    Gu, Shan-Qiang
    Tong, Xue-Fang
    Gaodianya Jishu/High Voltage Engineering, 2009, 35 (03): : 705 - 710