Differentiation and quantification of endogenous and recombinant-methionyl human leptin in clinical plasma samples by immunocapture/mass spectrometry

被引:13
作者
Wang, Yan [1 ]
Heilig, Joseph S. [1 ]
机构
[1] Amylin Pharmaceut Inc, San Diego, CA 92121 USA
关键词
Endogenous leptin; Recombinant-methionyl human leptin; Obesity; Immunocapture; LC-MS/MS; ELISA; TANDEM MASS-SPECTROMETRY; QUANTITATIVE-ANALYSIS; PARATHYROID-HORMONE; LC-MS/MS; PROTEINS; WEIGHT; PHARMACOKINETICS; BIOMARKERS; OBESITY; PROGRP;
D O I
10.1016/j.jpba.2012.06.018
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Therapeutic recombinant-methionyl human leptin (r-metHu-Leptin, Mr 16155) shares an identical amino acid sequence with endogenous leptin (endo-leptin, Mr 16024), with the addition of an N-terminal methionyl incorporated during recombinant expression in Escherichia coli. Current immunochemistry-based assays do not allow discrimination between the drug and endo-leptin because of cross reactivity. Using the immunoassay, the total plasma concentration measured in some clinical study subjects receiving r-metHu-Leptin can reach supra-physiological levels. To determine which leptin species contributes to the elevated concentrations detected in some subjects, a mass spectrometry-based method allowing discrimination and quantification of both leptin species was developed. Endo-leptin and r-metHu-Leptin were enriched from plasma matrix proteins by immuno capture, and subsequently injected onto a reversed phase analytical column coupled to an API 4000 Q-TRAP LC-MS/MS system. Multiple charge state ions and specific MRMs were monitored to provide unambiguous differentiation between endo-leptin and r-metHu-Leptin. A "top down" assay distinguishing the two forms of leptin was successfully developed and had a linear range from 15.63 to 1000 ng/ml, low limit of quantification of 15.63 ng/ml. The method was applied to selected clinical samples and revealed that the elevated leptin concentrations observed in some subjects reflected accumulation of r-metHu-Leptin. An LC-MS/MS method was developed for unambiguous differentiation of r-metHu-Leptin from endogenous leptin in human plasma. Using this method, specific quantitative information was obtained for pharmacokinetic studies in a clinical trial. The method should prove useful in quantifying this investigational drug against endo-leptin background in future clinical studies. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:440 / 446
页数:7
相关论文
共 50 条
  • [11] QUANTIFICATION OF CILNIDIPINE IN HUMAN PLASMA BY LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY
    Lee, Kyeong-Ryoon
    Chae, Yoon-Jee
    Lee, Jong-Hwa
    Kim, Dae-Duk
    Chong, Saeho
    Shim, Chang-Koo
    Chung, Suk-Jae
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2012, 35 (1-4) : 308 - 320
  • [12] Quantification of biotin in plasma samples by column switching liquid chromatography - tandem mass spectrometry
    Weimann, Allan
    Plomgaard, Peter
    Hilsted, Linda M.
    Poulsen, Henrik E.
    Larsen, Emil L.
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2021, 81 (02) : 127 - 136
  • [13] Simultaneous quantification of total antibody and antibody-conjugated drug for XMT-1522 in human plasma using immunocapture-liquid chromatography/mass spectrometry
    Xu, Ling
    Zhang, Zhiling
    Xu, Shengsheng
    Xu, Jian
    Lin, Zhongping John
    Lee, David H.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2019, 174 : 441 - 449
  • [14] Quantification of alkylresorcinols in human plasma by liquid chromatography/tandem mass spectrometry
    Ross, Alastair B.
    Redeuil, Karine
    Vigo, Mario
    Rezzi, Serge
    Nagy, Kornel
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2010, 24 (05) : 554 - 560
  • [15] A liquid chromatography/tandem mass spectrometry method for the simultaneous quantification of valsartan and hydrochlorothiazide in human plasma
    Li, Hao
    Wang, Yingwu
    Jiang, Yao
    Tang, Yunbiao
    Wang, Jiang
    Zhao, Limei
    Gu, Jingkai
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 852 (1-2): : 436 - 442
  • [16] Simultaneous Quantification of Adalimumab and Infliximab in Human Plasma by Liquid Chromatography-Tandem Mass Spectrometry
    Jourdil, Jean-Francois
    Nemoz, Benjamin
    Gautier-Veyret, Elodie
    Romero, Charlotte
    Stanke-Labesque, Francoise
    THERAPEUTIC DRUG MONITORING, 2018, 40 (04) : 417 - 424
  • [17] A validated method for the quantification of fosfomycin in human plasma by liquid chromatography-tandem mass spectrometry
    Martens-Lobenhoffer, Jens
    Bode-Boeger, Stefanie M.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 990 : 164 - 168
  • [18] Quantification of Azithromycin in Human Plasma by Liquid Chromatography Tandem Mass Spectrometry: Application to a Bioequivalence Study
    Jiang, B.
    Chen, J.
    Ruan, Z.
    Lou, H.
    Yu, L.
    ARZNEIMITTELFORSCHUNG-DRUG RESEARCH, 2012, 62 (05): : 230 - 235
  • [19] Quantification of vigabatrin in human plasma by liquid chromatography - Electrospray tandem mass spectrometry
    Matar, KM
    Abdel-Hamid, ME
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2005, 28 (03) : 395 - 406
  • [20] Microextraction in packed syringe/liquid chromatography/electrospray tandem mass spectrometry for quantification of acebutolol and metoprolol in human plasma and urine samples
    El-Beqqali, Aziza
    Kussak, Anders
    Blomberg, Lars
    Abdel-Rehim, Mohamed
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2007, 30 (04) : 575 - 586