Automated Image Registration for Stand-Alone Micro-PET and Micro-CT

被引:2
作者
Yang, Jing [1 ]
Li, Guang [1 ]
Sun, Yi [1 ]
Huang, Hongbo [2 ]
Zhao, Fukuan [2 ]
Luo, Shouhua [1 ]
机构
[1] Southeast Univ, Sch Biol Sci & Med Engn, Nanjing 210096, Jiangsu, Peoples R China
[2] Jiangsu Inst Nucl Med, Wuxi 214063, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
Micro-PET; Micro-CT; Multi-Modality Image Fusion; Small Animal Imaging; CLOSED-FORM SOLUTION; GOLD NANORODS; IN-VIVO; FUSION; COREGISTRATION; QUATERNIONS;
D O I
10.1166/jnn.2016.11389
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Combination of micro Positron Emission Tomography with micro Computed Tomography (microPET/micro-CT) has been widely used in clinical and scientific research. Multimodality of microPET/micro-CT makes it a representative hybrid imaging device. However, its high prices hampered its widespread use. Previous work was concentrated on achieving complicated process of fusion images manually. Registration problem is a prerequisite for image fusion. Therefore, an effective method for accurate image registration between stand-alone micro-PET and micro-CT scanners is needed. Presented work proposes a multimodal images using separate micro-PET and microCT devices as well as implements a registration method by combining hardware and software. An animal chamber was designed which can be mounted on micro-PET and micro-CT scanners separately. Four catheters filled with (18)F2-deoxy-2-fluoro-D-glucose (F-18-FDG) solution were used to generate the spatial relation between PET and CT images. The transformed matrix was calculated during each registration experiment instead of a predetermined one, which decreased errors introduced by uncertainty in the position of animal chamber. In this way multi-modality biomedical images are acquired automatically without human intervention. These in vivo and test experimental results show the accuracy of this method. As stated above, this method is effective and robust for multi-modality image fusion.
引用
收藏
页码:6903 / 6909
页数:7
相关论文
共 50 条
  • [21] Determining Glucose Metabolism Kinetics Using 18F-FDG Micro-PET/CT
    Cochran, Blake J.
    Ryder, William J.
    Parmar, Arvind
    Klaeser, Kerstin
    Reilhac, Anthonin
    Angelis, Georgios I.
    Meikle, Steven R.
    Barter, Philip J.
    Rye, Kerry-Anne
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2017, (123):
  • [22] Functional Imaging of Brown Fat in Mice with 18F-FDG micro-PET/CT
    Wang, Xukui
    Minze, Laurie J.
    Shi, Zheng-Zheng
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2012, (69):
  • [23] Small animal micro-CT colonography
    Durkee, Benjamin Y.
    Weichert, Jamey P.
    Halberg, Richard B.
    METHODS, 2010, 50 (01) : 36 - 41
  • [24] Robust Automated Mouse Micro-CT Segmentation Using Swin UNEt TRansformers
    Jiang, Lu
    Xu, Di
    Xu, Qifan
    Chatziioannou, Arion
    Iwamoto, Keisuke S.
    Hui, Susanta
    Sheng, Ke
    BIOENGINEERING-BASEL, 2024, 11 (12):
  • [25] Micro-CT Imaging of MEMS Components
    Ryan F. Fisher
    David E. Hintenlang
    Journal of Nondestructive Evaluation, 2008, 27 : 115 - 125
  • [26] Micro-CT系统的设计
    鄢苏鹏
    刘正明
    中国医疗设备, 2018, 33 (09) : 46 - 48+52
  • [27] Micro-CT with respiratory and cardiac gating
    Badea, C
    Hedlund, LW
    Johnson, GA
    MEDICAL PHYSICS, 2004, 31 (12) : 3324 - 3329
  • [28] Interior micro-CT with an offset detector
    Sen Sharma, Kriti
    Gong, Hao
    Ghasemalizadeh, Omid
    Yu, Hengyong
    Wang, Ge
    Cao, Guohua
    MEDICAL PHYSICS, 2014, 41 (06)
  • [29] Micro-CT Imaging of MEMS Components
    Fisher, Ryan F.
    Hintenlang, David E.
    JOURNAL OF NONDESTRUCTIVE EVALUATION, 2008, 27 (04) : 115 - 125
  • [30] Current Concepts for Experimental Micro-CT in Small Animals
    Bag, S.
    Schambach, S. J.
    Boll, H.
    Schilling, L.
    Groden, C.
    Brockmann, M. A.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2010, 182 (05): : 390 - 403