Robustness Against Interfraction Prostate Movement in Scanned Ion Beam Radiation Therapy

被引:10
作者
Jelen, Urszula [1 ,4 ]
Ammazzalorso, Filippo [1 ]
Chanrion, Marie-Anne [1 ,2 ,3 ]
Graef, Sebastian [1 ]
Zink, Klemens [4 ]
Engenhart-Cabillic, Rita [1 ]
Wittig, Andrea [1 ]
机构
[1] Univ Marburg, Dept Radiotherapy & Radiat Oncol, Marburg, Germany
[2] Univ Lyon 1, F-69365 Lyon, France
[3] Univ Appl Sci, Giessen, Germany
[4] Univ Med Ctr Giessen & Marburg, Dept Radiotherapy & Radiat Oncol, D-35043 Marburg, Germany
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2012年 / 84卷 / 02期
关键词
PROTON THERAPY; CANCER TREATMENT; BONY ANATOMY; ONLINE; RADIOTHERAPY; MOTION; ERRORS;
D O I
10.1016/j.ijrobp.2012.03.058
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To assess the robustness of scanned ion beam treatment plans against the interfraction internal target motion and evaluate the limits of validity of target-based isocenter realignment for prostate cancer radiation therapy. Methods and Materials: For 12 prostate patients, scanned beam carbon ion treatment plans were prepared using 2 lateral opposed beams and the raster scanning technique with different clinical target volume (CTV) to planning target volume (PTV) margins (2-10 mm). Internal target motion of 2-15 mm in anteroposterior (AP), superoinferior (SI), and left-to-right (LR) directions was simulated by displacing the CTV contours with respect to the computed tomography data. The plans were recalculated with and without target-based isocenter realignment and the CTV coverage was assessed. Results: For CTV shifts within the applied planning margin, the CI-98% is greater than 98.0%, both with and without isocenter realignment. Without realignment, because of the sharp lateral gradients, the CI-98% shows rapid fall as soon as the target shift exceeds the applied planning margin for all displacement directions. With isocenter realignment, the coverage improves notably for shifts in AP and SI directions and the CI-98% is restored to >95.0% for plans optimized with a 2-mm margin, >97% with a 3-mm margin, and >98% with larger margins. For large corrections, predominately in AP direction, cold spots in the CTV may occur. Their magnitude is dependent on the patients' individual anatomies. Conclusions: Within the physiological limits of internal prostate movement, target-based isocenter realignment results in improved CTV coverage for shifts in AP and SI directions exceeding the applied planning margin. Assuming optimal patient setup reproducibility (eg, immobilization, setup error correction, patient preparation protocols), hence negligible interfraction bone and soft-tissue variations, changes in traversed densities resulting from target-based realignment applied with a reduced planning margin do not induce significant dose deterioration in most of the cases. (C) 2012 Elsevier Inc.
引用
收藏
页码:E257 / E262
页数:6
相关论文
共 19 条
[1]  
[Anonymous], 2007, J ICRU, V7
[2]   Quantification of prostate and seminal vesicle interfraction variation during IMRT [J].
Frank, Steven J. ;
Dong, Lei ;
Kudchadker, Rajat J. ;
De Crevoisier, Renaud ;
Lee, Andrew K. ;
Cheung, Rex ;
Choi, Seungtaek ;
O'Daniel, Jennifer ;
Tucker, Susan L. ;
Wang, He ;
Kuban, Deborah A. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 71 (03) :813-820
[3]  
Iancu G, 2009, HEAV IONS THER SPAC
[4]   Treatment planning for heavy-ion radiotherapy:: physical beam model and dose optimization [J].
Krämer, M ;
Jäkel, O ;
Haberer, T ;
Kraft, G ;
Schardt, D ;
Weber, U .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (11) :3299-3317
[5]   Observations on real-time prostate gland motion using electromagnetic tracking [J].
Langen, Katja M. ;
Willoughby, Twyla R. ;
Meeks, Sanford L. ;
Santhanam, Anand ;
Cunningham, Alexis ;
Levine, Lisa ;
Kupelian, Patrick A. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 71 (04) :1084-1090
[6]  
Litzenberg DW, 2012, PROSTATE CANC, P130
[7]   A comparison of the use of bony anatomy and internal markers for offline verification and an evaluation of the potential benefit of online and offline verification protocols for prostate radiotherapy [J].
Mcnair, Helen A. ;
Hansen, Vibeke N. ;
Parker, Christopher C. ;
Evans, Phil M. ;
Norman, Andrew ;
Miles, Elizabeth ;
Harris, Emma J. ;
Del-Acroix, Louise ;
Smith, Elizabeth ;
Keane, Richard ;
Khoo, Vincent S. ;
Thompson, Alan C. ;
Dearnaley, David P. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 71 (01) :41-50
[8]   SPOT SCANNING PROTON BEAM THERAPY FOR PROSTATE CANCER: TREATMENT PLANNING TECHNIQUE AND ANALYSIS OF CONSEQUENCES OF ROTATIONAL AND TRANSLATIONAL ALIGNMENT ERRORS [J].
Meyer, Jeff ;
Bluett, Jaques ;
Amos, Richard ;
Levy, Larry ;
Choi, Seungtaek ;
Nguyen, Quynh-Nhu ;
Zhu, X. Ron ;
Gillin, Michael ;
Lee, Andrew .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (02) :428-434
[9]   Evaluation of therapeutic potential of heavy ion therapy for patients with locally advanced prostate cancer [J].
Nikoghosyan, A ;
Schulz-Ertner, D ;
Didinger, B ;
Jäkel, O ;
Zuna, I ;
Höss, A ;
Wannenmacher, M ;
Debus, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 58 (01) :89-97
[10]   Evaluation of daily online set-up errors and organ displacement uncertainty during conformal radiation treatment of the prostate [J].
Osei, E. K. ;
Jiang, R. ;
Barnett, R. ;
Fleming, K. ;
Panjwani, D. .
BRITISH JOURNAL OF RADIOLOGY, 2009, 82 (973) :49-61