Review of non-invasive blood pressure measurement in animals: Part 2-Evaluation of the performance of non-invasive devices

被引:0
作者
Skelding, Alicia [1 ]
Valverde, Alexander [2 ]
机构
[1] Toronto Anim Hlth Partners Emergency & Specialty, Dept Anesthesiol, Toronto, ON M3B 2R2, Canada
[2] Univ Guelph, Ontario Vet Coll, Dept Clin Studies, Guelph, ON N1G 2W1, Canada
来源
CANADIAN VETERINARY JOURNAL-REVUE VETERINAIRE CANADIENNE | 2020年 / 61卷 / 05期
关键词
HIGH-DEFINITION OSCILLOMETRY; DOPPLER ULTRASONIC DEVICES; FLOW DETECTOR; MONITOR; AGREEMENT; ACCURACY; DOGS; CUFF; HYPERTENSION; PRECISION;
D O I
暂无
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Arterial blood pressure is a common parameter evaluated in conscious and anesthetized veterinary patients for a variety of reasons. Non-invasive blood pressure measurement techniques, such as Doppler ultrasound and oscillometry, are attractive in certain veterinary patients due to their availability and ease of use. The greatest limitation to non-invasive blood pressure monitoring can be its inaccuracy, particularly in hypotensive or hypertensive patients and in certain species. Part 1 of this 2-part review summarized the current techniques available to non-invasively measure arterial blood pressure in veterinary species and discussed validation of non- invasive devices. Part 2 summarizes the veterinary literature that evaluates the use of non-invasive blood pressure measurement techniques in conscious and anesthetized species and develops general conclusions for proper use and interpretation of non-invasive blood pressure devices.
引用
收藏
页码:481 / 498
页数:18
相关论文
共 58 条
  • [1] Comparison of invasive and oscillometric blood pressure measurement techniques in anesthetized sheep, goats, and cattle
    Aarnes, Turi K.
    Hubbell, John A. E.
    Lerche, Phillip
    Bednarski, Richard M.
    [J]. VETERINARY ANAESTHESIA AND ANALGESIA, 2014, 41 (02) : 174 - 185
  • [2] Aarnes TK, 2012, CAN VET J, V53, P881
  • [3] Agreement between direct and indirect blood pressure measurements obtained from anesthetized Hispaniolan Amazon parrots
    Acierno, Mark J.
    da Cunha, Anderson
    Smith, Julie
    Tully, Thomas N., Jr.
    Guzman, David Sanchez-Migallon
    Serra, Verna
    Mitchell, Mark A.
    [J]. JAVMA-JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION, 2008, 233 (10): : 1587 - 1590
  • [4] Measuring the level of agreement between directly measured blood pressure and pressure readings obtained with a veterinary-specific oscillometric unit in anesthetized dogs
    Acierno, Mark J.
    Fauth, Erika
    Mitchell, Mark A.
    da Cunha, Anderson
    [J]. JOURNAL OF VETERINARY EMERGENCY AND CRITICAL CARE, 2013, 23 (01) : 37 - 40
  • [5] Agreement between directly measured blood pressure and pressures obtained with three veterinary-specific oscillometric units in cats
    Acierno, Mark J.
    Seaton, Diana
    Mitchell, Mark A.
    da Cunha, Anderson
    [J]. JAVMA-JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION, 2010, 237 (04): : 402 - 406
  • [6] Comparison between invasive blood pressure and a non-invasive blood pressure monitor in anesthetized sheep
    Almeida, Daniel
    Barletta, Michele
    Mathews, Lindsey
    Graham, Lynelle
    Quandt, Jane
    [J]. RESEARCH IN VETERINARY SCIENCE, 2014, 97 (03) : 582 - 586
  • [7] INDIRECT DOPPLER ULTRASONIC MEASUREMENT OF ARTERIAL BLOOD-PRESSURE RESULTS IN A LARGE MEASUREMENT ERROR IN DORSALLY RECUMBENT ANESTHETIZED HORSES
    BAILEY, JE
    DUNLOP, CI
    CHAPMAN, PL
    DEMME, WC
    ALLEN, SL
    HEATH, RB
    CRUMP, KT
    GOLDEN, CS
    WAGNER, AE
    [J]. EQUINE VETERINARY JOURNAL, 1994, 26 (01) : 70 - 73
  • [8] DOPPLER ULTRASONOGRAPHIC, OSCILLOMETRIC SPHYGMOMANOMETRIC, AND PHOTOPLETHYSMOGRAPHIC TECHNIQUES FOR NONINVASIVE BLOOD-PRESSURE MEASUREMENT IN ANESTHETIZED CATS
    BINNS, SH
    SISSON, DD
    BUOSCIO, DA
    SCHAEFFER, DJ
    [J]. JOURNAL OF VETERINARY INTERNAL MEDICINE, 1995, 9 (06) : 405 - 414
  • [9] Comparison of direct and indirect (oscillometric) measurements of arterial blood pressure in conscious dogs
    Bodey, AR
    Michell, AR
    Bovee, KC
    Buranakurl, C
    Garg, T
    [J]. RESEARCH IN VETERINARY SCIENCE, 1996, 61 (01) : 17 - 21
  • [10] Comparison of ultrasonic Doppler flow monitor, oscillometric, and direct arterial blood pressure measurements in ill dogs
    Bosiack, Ann P.
    Mann, F. A.
    Dodam, John R.
    Wagner-Mann, Colette C.
    Branson, Keith R.
    [J]. JOURNAL OF VETERINARY EMERGENCY AND CRITICAL CARE, 2010, 20 (02) : 207 - 215