Development of a TOF-PET Detector Capable of Four-Layer DOI Encoding with a Single-Layer Crystal Array

被引:0
|
作者
Tsuda, Tomoaki [1 ]
Furumiya, Tetsuo [1 ]
Ohi, Lunichi [1 ]
Tonami, Hiromichi [1 ]
Kitamura, Keishi [1 ]
机构
[1] Shimadzu Co Ltd, Technol Res Lab, Kyoto 6190237, Japan
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In positron emission tomography (PET), depth of interaction (DOI) detectors are preferable for providing both high spatial resolution and high sensitivity. In previous work, we developed a four-layer DOI detector and invented and proved it works successfully for a time-of-flight (TOF) PET scanner. The detector consists of four layers of a 16 x 16 Lu1.8Gd0.2SiO5 (LGSO) crystal array. Each crystal element is 3.0 mm square and 5, 6, 7, and 8 mm in depth, and the four-layer DOI encoding is allowed by changing the reflector arrangement for each layer. However, the gaps between layers degrade the performance of the detector such as the energy and time resolution. In addition, the increase in the number of crystal elements increases the assembly time of the crystal blocks. In this work, we have developed a new TOF-PET detector capable of four-layer DOI encoding with a single-layer 16 x 16 crystal array. Each crystal element of LGSO is 3.0 mm square and 26 mm in depth, but the reflector arrangement is same as in the conventional DOI-TOF detector. The crystal block is coupled to a 64-channel flat panel position sensitive photomultiplier tube which has 8 x 8 multi anodes at intervals of 6.08 mm. The proposed detector was arranged opposite a BaF2 detector and was uniformly irradiated using 511 keV gamma rays from a Na-22 point source. All crystal elements and DOI layers were expressed on a two-dimensional position histogram without overlapping. In comparison with the conventional DOI-TOF detector, the energy resolution was improved from 13.0% to 11.2% and the time resolution was improved from 476 ps to 455 ps. These results demonstrated the proposed DOI-TOF detector is suitable for practical use by reducing cost while improving energy and time resolutions.
引用
收藏
页码:3012 / 3014
页数:3
相关论文
共 50 条
  • [41] Performance evaluation of a high-resolution brain PET scanner using four-layer MPPC DOI detectors
    Watanabe, Mitsuo
    Saito, Akinori
    Isobe, Takashi
    Ote, Kibo
    Yamada, Ryoko
    Moriya, Takahiro
    Omura, Tomohide
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (17): : 7148 - 7166
  • [42] A validated Geant4 model of a whole-body PET scanner with four-layer DOI detectors
    Ahmed, Abdella M.
    Chacon, Andrew
    Rutherford, Harley
    Akamatsu, Go
    Mohammadi, Akram
    Nishikido, Fumihiko
    Tashima, Hideaki
    Yoshida, Eiji
    Yamaya, Taiga
    Franklin, Daniel R.
    Rosenfeld, Anatoly
    Guatelli, Susanna
    Safavi-Naeini, Mitra
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (23):
  • [43] A factorial, randomized trial of pentoxifylline or placebo, four-layer or single-layer compression, and knitted viscose or hydrocolloid dressings for venous ulcers
    Nelson, E. Andrea
    Prescott, Robin J.
    Harper, Douglas R.
    Gibson, Barbara
    Brown, Dorothy
    Vaughan Ruckley, C.
    JOURNAL OF VASCULAR SURGERY, 2007, 45 (01) : 134 - 141
  • [44] Axial scalable add-on PET/MRI prototype based on four-layer DOI detectors integrated with a RF coil
    Nishikido, Fumihiko
    Obata, Takayuki
    Suga, Mikio
    Iwao, Yuma
    Tashima, Hideaki
    Yoshida, Eiji
    Akram, Md Shahadat Hossain
    Yamaya, Taiga
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2022, 1040
  • [45] Axial scalable add-on PET/MRI prototype based on four-layer DOI detectors integrated with a RF coil
    Nishikido, Fumihiko
    Obata, Takayuki
    Suga, Mikio
    Iwao, Yuma
    Tashima, Hideaki
    Yoshida, Eiji
    Akram, Md Shahadat Hossain
    Yamaya, Taiga
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2022, 1040
  • [46] Depth encoding PET detectors using single layer crystal array with different reflector arrangements along depths
    Zhao, Binqing
    Kuang, Zhonghua
    Sun, Mingdao
    Zhang, Chunhui
    Wang, Xiaohui
    Sang, Ziru
    Yang, Qian
    Wu, San
    Gao, Juan
    Ren, Ning
    Zhang, Xianming
    Hu, Zhanli
    Du, Junwei
    Yang, Yongfeng
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 945
  • [47] More than one photon detection using four-layer thermoelectric single-photon detector
    Kuzanyan, Astghik A.
    Nikoghosyan, Vahan R.
    Kuzanyan, Armen S.
    OPTICAL SENSING AND DETECTION VI, 2021, 11354
  • [48] Optimizing layer thickness for a TOF-DOI detector to be used in a long axial field-of-view PET scanner
    Schmall, Jeffrey
    Surti, Suleman
    Panetta, Joseph
    Karp, Joel
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03)
  • [49] Optimization Design of Crystal Thickness Combination for Dual-layer-offset DOI Detector for Brain PET
    Wei Q.
    Xu S.
    Dai T.
    Lyu Z.
    Xu T.
    Jiang N.
    Ma T.
    Liu Y.
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2020, 54 (09): : 1704 - 1708
  • [50] Spatial resolution evaluation with a pair of two four-layer DOI detectors for small animal PET scanner: jPET-RD
    Nishikido, Fumihiko
    Tsuda, Tomoaki
    Yoshida, Eiji
    Inadama, Naoko
    Shibuya, Kengo
    Yamaya, Taiga
    Kitamura, Keishi
    Takahashi, Kei
    Ohmura, Atsushi
    Murayama, Hideo
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 584 (01): : 212 - 218