Development of a TOF-PET Detector Capable of Four-Layer DOI Encoding with a Single-Layer Crystal Array

被引:0
|
作者
Tsuda, Tomoaki [1 ]
Furumiya, Tetsuo [1 ]
Ohi, Lunichi [1 ]
Tonami, Hiromichi [1 ]
Kitamura, Keishi [1 ]
机构
[1] Shimadzu Co Ltd, Technol Res Lab, Kyoto 6190237, Japan
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In positron emission tomography (PET), depth of interaction (DOI) detectors are preferable for providing both high spatial resolution and high sensitivity. In previous work, we developed a four-layer DOI detector and invented and proved it works successfully for a time-of-flight (TOF) PET scanner. The detector consists of four layers of a 16 x 16 Lu1.8Gd0.2SiO5 (LGSO) crystal array. Each crystal element is 3.0 mm square and 5, 6, 7, and 8 mm in depth, and the four-layer DOI encoding is allowed by changing the reflector arrangement for each layer. However, the gaps between layers degrade the performance of the detector such as the energy and time resolution. In addition, the increase in the number of crystal elements increases the assembly time of the crystal blocks. In this work, we have developed a new TOF-PET detector capable of four-layer DOI encoding with a single-layer 16 x 16 crystal array. Each crystal element of LGSO is 3.0 mm square and 26 mm in depth, but the reflector arrangement is same as in the conventional DOI-TOF detector. The crystal block is coupled to a 64-channel flat panel position sensitive photomultiplier tube which has 8 x 8 multi anodes at intervals of 6.08 mm. The proposed detector was arranged opposite a BaF2 detector and was uniformly irradiated using 511 keV gamma rays from a Na-22 point source. All crystal elements and DOI layers were expressed on a two-dimensional position histogram without overlapping. In comparison with the conventional DOI-TOF detector, the energy resolution was improved from 13.0% to 11.2% and the time resolution was improved from 476 ps to 455 ps. These results demonstrated the proposed DOI-TOF detector is suitable for practical use by reducing cost while improving energy and time resolutions.
引用
收藏
页码:3012 / 3014
页数:3
相关论文
共 50 条
  • [1] Advantage of the Four-Layer DOI Information in the Time Resolution for a TOF-PET Detector
    Tsuda, Tomoaki
    Kitamura, Keishi
    Ohi, Junichi
    Tonami, Hiromichi
    Satoh, Masanobu
    Kumazawa, Yoshihiko
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 3201 - 3204
  • [2] Timing resolution improvement using DOI information in a four-layer scintillation detector for TOF-PET
    Shibuya, Kengo
    Nishikido, Fumihiko
    Tsuda, Tomoaki
    Kobayashi, Tetsuya
    Lam, Chihfung
    Yamaya, Taiga
    Yoshida, Eiji
    Inadama, Naoko
    Murayama, Hideo
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 593 (03): : 572 - 577
  • [3] Four-layer DOI-PET detector with a silicon photomultiplier array
    Nishikido, Fumihiko
    Inadama, Naoko
    Shibuya, Kengo
    Yoshida, Eiji
    Yamaya, Taiga
    Oda, Ichiro
    Kitamura, Keishi
    Murayama, Hideo
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 3198 - +
  • [4] Development of a 4-Layer DOI TOF-PET detector module with a 6 mm-pitch MPPC array
    Takyu, Sodai
    Yoshida, Eiji
    Nishikido, Fumihiko
    Nitta, Munetaka
    Akamatsu, Go
    Yamaya, Taiga
    2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,
  • [5] Four-layer DOI detector with a relative offset in animal PET system
    Ito, Mikiko
    Hong, Seong Jong
    Lee, Jae Sung
    Kwon, Sun Il
    Lee, Geon Song
    Park, Kwang Suk
    Hong, Byungsik
    Lee, Kyong Sei
    Lee, Seok Jae
    Rhee, June Tak
    Sim, Kwang-Souk
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 4296 - +
  • [6] Preliminary evaluation of four-layer BGO DOI-detector for PET
    Inadama, N
    Murayama, H
    Yamaya, T
    Kitamura, K
    Yamashita, T
    Kawai, H
    Tsuda, T
    Sato, M
    Ono, Y
    Hamamoto, M
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (01) : 30 - 34
  • [7] Development of a High-Resolution Four-Layer DOI Detector Using MPPCs for Brain PET
    Omura, T.
    Moriya, T.
    Yamada, R.
    Yamauchi, H.
    Saito, A.
    Sakai, T.
    Miwa, T.
    Watanabe, M.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 3560 - 3563
  • [8] A Four-Layer DOI Detector With a Relative Offset for Use in an Animal PET System
    Ito, Mikiko
    Lee, Jae Sung
    Kwon, Sun Il
    Lee, Geon Song
    Hong, Byungsik
    Lee, Kyong Sei
    Sim, Kwang-Souk
    Lee, Seok Jae
    Rhee, June Tak
    Hong, Seong Jong
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2010, 57 (03) : 976 - 981
  • [9] Development of a four-layer DOI PET detector using long crystals segmented by subsurface laser engraving
    Mohammadi, Akram
    Nishikido, Fumihiko
    Inadama, Naoko
    Sakai, Toshiaki
    Yamaya, Taiga
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2023, 1056
  • [10] Monte Carlo Simulation of Four-layer DOI Detector with Relative Offset in Animal PET
    Hwang, Ji Yeon
    Lee, Seung-Jae
    Baek, Cheol-Ha
    Ito, M.
    Hong, S. J.
    Lee, J. S.
    Chung, Y. H.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3173 - +