Test-Retest Reliability of the 40 Hz EEG Auditory Steady-State Response

被引:57
|
作者
McFadden, Kristina L. [1 ,2 ]
Steinmetz, Sarah E. [1 ,2 ]
Carroll, Adam M. [1 ]
Simon, Steven T. [2 ]
Wallace, Alissa [1 ,2 ]
Rojas, Donald C. [1 ,2 ]
机构
[1] Univ Colorado, Dept Psychiat, Aurora, CO 80045 USA
[2] Univ Colorado, Sch Med, Aurora, CO USA
来源
PLOS ONE | 2014年 / 9卷 / 01期
关键词
SCHIZOTYPAL PERSONALITY-DISORDER; GAMMA-BAND ACTIVITY; 1ST-DEGREE RELATIVES; SELECTIVE ATTENTION; COGNITIVE-PROCESSES; BRAIN OSCILLATIONS; FREQUENCY-ANALYSIS; EVOKED-RESPONSES; BIPOLAR DISORDER; MODULATED TONES;
D O I
10.1371/journal.pone.0085748
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Auditory evoked steady-state responses are increasingly being used as a marker of brain function and dysfunction in various neuropsychiatric disorders, but research investigating the test-retest reliability of this response is lacking. The purpose of this study was to assess the consistency of the auditory steady-state response (ASSR) across sessions. Furthermore, the current study aimed to investigate how the reliability of the ASSR is impacted by stimulus parameters and analysis method employed. The consistency of this response across two sessions spaced approximately 1 week apart was measured in nineteen healthy adults using electroencephalography (EEG). The ASSR was entrained by both 40 Hz amplitude-modulated white noise and click train stimuli. Correlations between sessions were assessed with two separate analytical techniques: a) channel-level analysis across the whole-head array and b) signal-space projection from auditory dipoles. Overall, the ASSR was significantly correlated between sessions 1 and 2 (p < 0.05, multiple comparison corrected), suggesting adequate test-retest reliability of this response. The current study also suggests that measures of inter-trial phase coherence may be more reliable between sessions than measures of evoked power. Results were similar between the two analysis methods, but reliability varied depending on the presented stimulus, with click train stimuli producing more consistent responses than white noise stimuli.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Intracerebral Sources of Human Auditory Steady-State Responses
    Anthony T. Herdman
    Otavio Lins
    Patricia Van Roon
    David R. Stapells
    Michael Scherg
    Terence W. Picton
    Brain Topography, 2002, 15 : 69 - 86
  • [32] The use of phase in the detection of auditory steady-state responses
    Picton, TW
    Dimitrijevic, A
    John, MS
    Van Roon, P
    CLINICAL NEUROPHYSIOLOGY, 2001, 112 (09) : 1698 - 1711
  • [33] Test-retest reliability, feasibility and clinical correlates of the Eurofit test battery in people with bipolar disorder
    Vancampfort, Davy
    Sienaert, Pascal
    Wyckaert, Sabine
    De Hert, Marc
    Stubbs, Brendon
    Rosenbaum, Simon
    Buys, Roselien
    Probst, Michel
    PSYCHIATRY RESEARCH, 2015, 228 (03) : 620 - 625
  • [34] Effects of intermodal attention on the auditory steady-state response and the event-related potential
    Saupe, Katja
    Widmann, Andreas
    Bendixen, Alexandra
    Mueller, Matthias M.
    Schroeger, Erich
    PSYCHOPHYSIOLOGY, 2009, 46 (02) : 321 - 327
  • [35] 40 Hz auditory steady-state responses in patients with disorders of consciousness: Correlation between phase-locking index and Coma Recovery Scale-Revised score
    Binder, Marek
    Gorska, Urszula
    Griskova-Bulanova, Inga
    CLINICAL NEUROPHYSIOLOGY, 2017, 128 (05) : 799 - 806
  • [36] MK-801 disrupts and nicotine augments 40 Hz auditory steady state responses in the auditory cortex of the urethane-anesthetized rat
    Sivarao, Digavalli V.
    Frenkel, Mikhail
    Chen, Ping
    Healy, Francine L.
    Lodge, Nicholas J.
    Zaczek, Robert
    NEUROPHARMACOLOGY, 2013, 73 : 1 - 9
  • [37] Automated subcortical segmentation using FIRST: Test-retest reliability, interscanner reliability, and comparison to manual segmentation
    Nugent, Allison C.
    Luckenbaugh, David A.
    Wood, Suzanne E.
    Bogers, Wendy
    Zarate, Carlos A., Jr.
    Drevets, Wayne C.
    HUMAN BRAIN MAPPING, 2013, 34 (09) : 2313 - 2329
  • [38] Test-retest reliability of component process variables within the Hopkins verbal learning test-revised
    Woods, SP
    Scott, JC
    Conover, E
    Marcotte, TD
    Heaton, RK
    Grant, I
    ASSESSMENT, 2005, 12 (01) : 96 - 100
  • [39] Extended testing with the dot-probe task increases test-retest reliability and validity
    Aday, Jacob S.
    Carlson, Joshua M.
    COGNITIVE PROCESSING, 2019, 20 (01) : 65 - 72
  • [40] Enhanced Auditory Steady-State Response Using an Optimized Chirp Stimulus-Evoked Paradigm
    Liu, Xiaoya
    Liu, Shuang
    Guo, Dongyue
    Sheng, Yue
    Ke, Yufeng
    An, Xingwei
    He, Feng
    Ming, Dong
    SENSORS, 2019, 19 (03):