A Monte Carlo investigation of the dose distribution for 60Co high dose rate brachytherapy source in water and in different media

被引:10
|
作者
Badry, Hamza [1 ]
Oufni, Lhoucine [1 ]
Ouabi, Hmad [2 ]
Hirayama, Hideo [3 ]
机构
[1] Sultan Moulay Slimane Univ, Fac Sci & Tech, Dept Phys, LPM ERM, BP 523, Beni Mellal 23000, Morocco
[2] Oncol Ctr Al Azhar, Rabat, Morocco
[3] High Energy Accelerator Res Org, KEK, Appl Res Lab, 1-1 Oho, Tsukuba, Ibaraki 3050801, Japan
关键词
Monte Carlo; Brachytherapy; Dose; Co-60; TECHNICAL NOTE;
D O I
10.1016/j.apradiso.2018.02.016
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
In this study, the dosimetric characterization for The BEBIG Co-60 High Dose Rate (HDR) brachytherapy source model Co0.A86 was investigated and the validity of the EGS5 Monte Carlo code to reproduce the dosimetric parameters in water phantom was checked. In addition, the dose distribution for different tissue phantoms was calculated. The BEBIG Co-60 HDR brachytherapy source was modeled using EGS5 Monte Carlo simulation code. A description of the source design, geometry and materials used in this work were provided. According to the update TG43-U1 formalism of AAPM, the air kerma strength, the dose rate constant, 2D rectangular dose distribution in water were calculated, moreover, the results of the radial dose function were obtained in water and different tissue phantoms; bone, lung, adipose tissue, breast and muscle. The obtained results were tabulated and presented in graphical formats for the comparison with available data. The calculated value of the air kerma strength of this study, 3.0419 U Bq(-1), agree well with that of the other Monte Carlo calculation. The 2D look-up along-away rectangular dose were obtained in water, the results were similar to the published data for all distances larger than 1 an, for the distances near to the source region on the transversal source axis small differences are apparent. The radial dose function were presented in graphical format for the comparison between the dose distribution in water and different tissue phantoms. The EGS5 results obtained in this study shows good consistency with the published data for the dosimetric parameters of the of the BEBIG Co-60 HDR brachytherapy source. It seems that the radial dose function calculated in water differed in tissue phantoms due to the atomic composition and densities for media that are not taken account by the TG43-U1 formalism.
引用
收藏
页码:104 / 110
页数:7
相关论文
共 50 条
  • [41] A Monte Carlo approach to calculate dose distribution around the lineal brachytherapy sources
    Vieira, JW
    Lima, FRA
    Kramer, R
    CELLULAR AND MOLECULAR BIOLOGY, 2002, 48 (05) : 445 - 450
  • [42] Monte Carlo and experimental high dose rate 192Ir brachytherapy dosimetry with microDiamond detectors
    Rossi, Giulio
    Gainey, Mark
    Thomann, Benedikt
    Kollefrath, Michael
    Wuerfel, Jan
    Allgaier, Bernd
    Baltas, Dimos
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2019, 29 (03): : 272 - 281
  • [43] A Monte Carlo study on dose distribution evaluation of Flexisource Ir-192 brachytherapy source
    Alizadeh, Majid
    Ghorbani, Mandi
    Haghparast, Abbas
    Zare, Naser
    Moghaddas, Toktam Ahmadi
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2015, 20 (03) : 204 - 209
  • [44] Monte Carlo simulated correction factors for high dose rate brachytherapy postal dosimetry audit methodology
    Chelminski, Krzysztof
    Dimitriadis, Alexis
    Abdulrahim, Roua
    Kazantsev, Pavel
    Granizo-Roman, Evelyn
    Kalinowski, Jonathan
    Enger, Shirin Abbasi
    Azangwe, Godfrey
    Carrara, Mauro
    Swamidas, Jamema
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2024, 32
  • [45] A Monte Carlo study on dose distribution validation of GZP6 Co-60 stepping source
    Toossi, Mohammad Taghi Bahreyni
    Abdollahi, Maliheh
    Ghorbani, Mahdi
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2013, 18 (02) : 112 - 116
  • [46] Dose assessment in high dose rate brachytherapy with cobalt-60 source for cervical cancer treatment: a phantom study
    Bour, Bright Kwadwo
    Inkoom, Stephen
    Tagoe, Samuel Nii Adu
    Amuasi, John Humphrey
    Sasu, Evans
    Hasford, Francis
    POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2020, 26 (04): : 243 - 250
  • [47] Prediction of the bias currents induced by 60Co via dose and dose rate
    Liu Changshi
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 2012, 167 (04): : 275 - 280
  • [48] A comparative assessment of inhomogeneity and finite patient dimension effects in 60Co and 192Ir high-dose-rate brachytherapy
    Fotina, Irina
    Zourari, Kyveli
    Lahanas, Vasileios
    Pantelis, Evaggelos
    Papagiannis, Panagiotis
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2018, 10 (01) : 73 - 84
  • [49] THUBrachy: fast Monte Carlo dose calculation tool accelerated by heterogeneous hardware for high-dose-rate brachytherapy
    Hu, An-Kang
    Qiu, Rui
    Liu, Huan
    Wu, Zhen
    Li, Chun-Yan
    Zhang, Hui
    Li, Jun-Li
    Yang, Rui-Jie
    NUCLEAR SCIENCE AND TECHNIQUES, 2021, 32 (03)
  • [50] Dose rate table for a 32P intravascular brachytherapy source from Monte Carlo calculations
    Bohm, TD
    Mourtada, FA
    Das, RK
    MEDICAL PHYSICS, 2001, 28 (08) : 1770 - 1775