A Monte Carlo investigation of the dose distribution for 60Co high dose rate brachytherapy source in water and in different media

被引:10
|
作者
Badry, Hamza [1 ]
Oufni, Lhoucine [1 ]
Ouabi, Hmad [2 ]
Hirayama, Hideo [3 ]
机构
[1] Sultan Moulay Slimane Univ, Fac Sci & Tech, Dept Phys, LPM ERM, BP 523, Beni Mellal 23000, Morocco
[2] Oncol Ctr Al Azhar, Rabat, Morocco
[3] High Energy Accelerator Res Org, KEK, Appl Res Lab, 1-1 Oho, Tsukuba, Ibaraki 3050801, Japan
关键词
Monte Carlo; Brachytherapy; Dose; Co-60; TECHNICAL NOTE;
D O I
10.1016/j.apradiso.2018.02.016
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
In this study, the dosimetric characterization for The BEBIG Co-60 High Dose Rate (HDR) brachytherapy source model Co0.A86 was investigated and the validity of the EGS5 Monte Carlo code to reproduce the dosimetric parameters in water phantom was checked. In addition, the dose distribution for different tissue phantoms was calculated. The BEBIG Co-60 HDR brachytherapy source was modeled using EGS5 Monte Carlo simulation code. A description of the source design, geometry and materials used in this work were provided. According to the update TG43-U1 formalism of AAPM, the air kerma strength, the dose rate constant, 2D rectangular dose distribution in water were calculated, moreover, the results of the radial dose function were obtained in water and different tissue phantoms; bone, lung, adipose tissue, breast and muscle. The obtained results were tabulated and presented in graphical formats for the comparison with available data. The calculated value of the air kerma strength of this study, 3.0419 U Bq(-1), agree well with that of the other Monte Carlo calculation. The 2D look-up along-away rectangular dose were obtained in water, the results were similar to the published data for all distances larger than 1 an, for the distances near to the source region on the transversal source axis small differences are apparent. The radial dose function were presented in graphical format for the comparison between the dose distribution in water and different tissue phantoms. The EGS5 results obtained in this study shows good consistency with the published data for the dosimetric parameters of the of the BEBIG Co-60 HDR brachytherapy source. It seems that the radial dose function calculated in water differed in tissue phantoms due to the atomic composition and densities for media that are not taken account by the TG43-U1 formalism.
引用
收藏
页码:104 / 110
页数:7
相关论文
共 50 条
  • [31] Monte Carlo and TLD dosimetry of an 192Ir high dose-rate brachytherapy source
    Karaiskos, P
    Angelopoulos, A
    Sakelliou, L
    Sandilos, P
    Antypas, C
    Vlachos, L
    Koutsouveli, E
    MEDICAL PHYSICS, 1998, 25 (10) : 1975 - 1984
  • [32] Design and characterization of flattening filter for high dose rate 192Ir and 60Co Leipzig applicators used in skin cancer brachytherapy: A Monte Carlo study
    Ghobadi, Parvin
    Farhood, Bagher
    Ghorbani, Mahdi
    Mohseni, Mehran
    COMPUTERS IN BIOLOGY AND MEDICINE, 2020, 123
  • [33] Monte Carlo characterization of 169Yb as a high-dose-rate source for brachytherapy application by FLUKA code
    Anjomrouz, Marzieh
    Sadeghi, Mahdi
    Haddadi, Asghar
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (04): : 196 - 205
  • [34] Dosimetric characterizations of GZP6 60Co high dose rate brachytherapy sources: application of superimposition method
    Toossi, Mohammad Taghi Bahreyni
    Ghorbani, Mahdi
    Mowlavi, Ali Asghar
    Meigooni, Ali Soleimani
    RADIOLOGY AND ONCOLOGY, 2012, 46 (02) : 170 - 178
  • [35] Verification of LDR brachytherapy dose distributions for different source geometries by Monte Carlo method
    Acun, Hediye
    Bozkurt, Ahmet
    Kemikler, Gonul
    Ozbay, Ismail
    Aslay, Isik
    TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY, 2012, 27 (04): : 181 - 188
  • [36] An analytic approach to the dosimetry of a new BEBIG Co-60 high-dose-rate brachytherapy source
    Bhola, Subhalaxmi
    Selvam, T. Palani
    Sridhar, Sahoo
    Vishwakarma, Ramkrishna S.
    JOURNAL OF MEDICAL PHYSICS, 2012, 37 (03) : 129 - 137
  • [37] Comparison of 192Ir, 169Yb, and 60Co high-dose rate brachytherapy sources for skin cancer treatment
    Safigholi, Habib
    Meigooni, Ali S.
    Song, William Y.
    MEDICAL PHYSICS, 2017, 44 (09) : 4426 - 4436
  • [38] Monte Carlo modeling of Co-60 HDR brachytherapy source in water and in different solid water phantom materials
    Sahoo, S.
    Selvam, T. Palani
    Vishwakarma, R. S.
    Chourasiya, G.
    JOURNAL OF MEDICAL PHYSICS, 2010, 35 (01) : 15 - 22
  • [39] Technical note: Dosimetric study for the new BEBIG 60Co HDR source used in brachytherapy in water and different media using Monte Carlo N-Particle eXtended code
    Elboukhari, Said
    Yamni, Khalid
    Ouabi, Hmad
    Bouassa, Taoufiq
    Mlouk, Lahcen Ait
    APPLIED RADIATION AND ISOTOPES, 2020, 159
  • [40] Monte Carlo dose calculations for high-dose-rate brachytherapy using GPU-accelerated processing
    Tian, Z.
    Zhang, M.
    Hrycushko, B.
    Albuquerque, K.
    Jiang, S. B.
    Jia, X.
    BRACHYTHERAPY, 2016, 15 (03) : 387 - 398