A Monte Carlo investigation of the dose distribution for 60Co high dose rate brachytherapy source in water and in different media

被引:10
|
作者
Badry, Hamza [1 ]
Oufni, Lhoucine [1 ]
Ouabi, Hmad [2 ]
Hirayama, Hideo [3 ]
机构
[1] Sultan Moulay Slimane Univ, Fac Sci & Tech, Dept Phys, LPM ERM, BP 523, Beni Mellal 23000, Morocco
[2] Oncol Ctr Al Azhar, Rabat, Morocco
[3] High Energy Accelerator Res Org, KEK, Appl Res Lab, 1-1 Oho, Tsukuba, Ibaraki 3050801, Japan
关键词
Monte Carlo; Brachytherapy; Dose; Co-60; TECHNICAL NOTE;
D O I
10.1016/j.apradiso.2018.02.016
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
In this study, the dosimetric characterization for The BEBIG Co-60 High Dose Rate (HDR) brachytherapy source model Co0.A86 was investigated and the validity of the EGS5 Monte Carlo code to reproduce the dosimetric parameters in water phantom was checked. In addition, the dose distribution for different tissue phantoms was calculated. The BEBIG Co-60 HDR brachytherapy source was modeled using EGS5 Monte Carlo simulation code. A description of the source design, geometry and materials used in this work were provided. According to the update TG43-U1 formalism of AAPM, the air kerma strength, the dose rate constant, 2D rectangular dose distribution in water were calculated, moreover, the results of the radial dose function were obtained in water and different tissue phantoms; bone, lung, adipose tissue, breast and muscle. The obtained results were tabulated and presented in graphical formats for the comparison with available data. The calculated value of the air kerma strength of this study, 3.0419 U Bq(-1), agree well with that of the other Monte Carlo calculation. The 2D look-up along-away rectangular dose were obtained in water, the results were similar to the published data for all distances larger than 1 an, for the distances near to the source region on the transversal source axis small differences are apparent. The radial dose function were presented in graphical format for the comparison between the dose distribution in water and different tissue phantoms. The EGS5 results obtained in this study shows good consistency with the published data for the dosimetric parameters of the of the BEBIG Co-60 HDR brachytherapy source. It seems that the radial dose function calculated in water differed in tissue phantoms due to the atomic composition and densities for media that are not taken account by the TG43-U1 formalism.
引用
收藏
页码:104 / 110
页数:7
相关论文
共 50 条
  • [21] Dosimetric investigation of a new high dose rate 192Ir brachytherapy source, IRAsource, by Monte Carlo method
    Rostami, Atefeh
    Hoseini, Mahdi
    Ghorbani, Mahdi
    Knaup, Courtney
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2020, 25 (01) : 139 - 145
  • [22] Dosimetric investigation of high dose rate Ir-192 source with Monte Carlo method
    Acun, H.
    Bozkurt, A.
    Kemikler, G.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2017, 15 (03): : 241 - 249
  • [23] Monte Carlo characterization of an ytterbium-169 high dose rate brachytherapy source with analysis of statistical uncertainty
    Medich, DC
    Tries, MA
    Munro, JJ
    MEDICAL PHYSICS, 2006, 33 (01) : 163 - 172
  • [24] Monte Carlo Evaluation for the Effect of Positional Inaccuracy of Source on Patient's Dose in High-Dose-Rate Brachytherapy
    Lee, Kyung Ja
    An, So Hyun
    Lee, Rena
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2009, 55 (06) : 2361 - 2365
  • [25] A Monte Carlo study of verification imaging in high dose rate brachytherapy
    Sheikh-Bagheri, D
    Munro, P
    MEDICAL PHYSICS, 1998, 25 (04) : 404 - 414
  • [26] Monte Carlo characterization of the M-19 high dose rate Iridium-192 brachytherapy source
    Medich, David C.
    Munro, John J., III
    MEDICAL PHYSICS, 2007, 34 (06) : 1999 - 2006
  • [27] A Monte Carlo evaluation for effects of probable dimensional uncertainties of low dose rate brachytherapy seeds on dose
    Camgoz, Berkay
    Kumru, Mehmet N.
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2014, 19 (05) : 301 - 309
  • [28] Monte Carlo dosimetry of a new 192Ir pulsed dose rate brachytherapy source
    Karaiskos, P
    Angelopoulos, A
    Pantelis, E
    Papagiannis, P
    Sakelliou, L
    Kouwenhoven, E
    Baltas, D
    MEDICAL PHYSICS, 2003, 30 (01) : 9 - 16
  • [29] HDRMC, an accelerated Monte Carlo dose calculator for high dose rate brachytherapy with CT-compatible applicators
    Chibani, Omar
    Ma, Charlie C-M
    MEDICAL PHYSICS, 2014, 41 (05)
  • [30] Monte Carlo characterization of a new Yb-169 high dose rate source for brachytherapy application
    Cazeca, Mario J.
    Medich, David C.
    Munro, John J., III