Prior-based artifact correction (PBAC) in computed tomography

被引:31
|
作者
Heusser, Thorsten [1 ]
Brehm, Marcus [1 ]
Ritschl, Ludwig [2 ]
Sawall, Stefan [1 ,3 ]
Kachelriess, Marc [1 ,3 ]
机构
[1] German Canc Res Ctr, D-69120 Heidelberg, Germany
[2] Ziehm Imaging GmbH, D-90451 Nurnberg, Germany
[3] Univ Erlangen Nurnberg, Inst Med Phys, D-91052 Erlangen, Germany
关键词
metal artifact reduction; truncation artifact reduction; limited angle artifact reduction; prior knowledge; sinogram inpainting; CONE-BEAM CT; FIELD-OF-VIEW; PRINCIPAL COMPONENT ANALYSIS; RADIATION-THERAPY; IMAGE-RECONSTRUCTION; SHADING CORRECTION; PROJECTION DATA; PLANNING CT; REDUCTION; ALGORITHM;
D O I
10.1118/1.4851536
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Image quality in computed tomography (CT) often suffers from artifacts which may reduce the diagnostic value of the image. In many cases, these artifacts result from missing or corrupt regions in the projection data, e.g., in the case of metal, truncation, and limited angle artifacts. The authors propose a generalized correction method for different kinds of artifacts resulting from missing or corrupt data by making use of available prior knowledge to perform data completion. Methods: The proposed prior-based artifact correction (PBAC) method requires prior knowledge in form of a planning CT of the same patient or in form of a CT scan of a different patient showing the same body region. In both cases, the prior image is registered to the patient image using a deformable transformation. The registered prior is forward projected and data completion of the patient projections is performed using smooth sinogram inpainting. The obtained projection data are used to reconstruct the corrected image. Results: The authors investigate metal and truncation artifacts in patient data sets acquired with a clinical CT and limited angle artifacts in an anthropomorphic head phantom data set acquired with a gantry-based flat detector CT device. In all cases, the corrected images obtained by PBAC are nearly artifact-free. Compared to conventional correction methods, PBAC achieves better artifact suppression while preserving the patient-specific anatomy at the same time. Further, the authors show that prominent anatomical details in the prior image seem to have only minor impact on the correction result. Conclusions: The results show that PBAC has the potential to effectively correct for metal, truncation, and limited angle artifacts if adequate prior data are available. Since the proposed method makes use of a generalized algorithm, PBAC may also be applicable to other artifacts resulting from missing or corrupt data. (C) 2014 American Association of Physicists in Medicine.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] Iterative metal artifact reduction for x-ray computed tomography using unmatched projector/backprojector pairs
    Zhang, Hanming
    Wang, Linyuan
    Li, Lei
    Cai, Ailong
    Hu, Guoen
    Yan, Bin
    MEDICAL PHYSICS, 2016, 43 (06) : 3019 - 3033
  • [42] A pseudo-discrete algebraic reconstruction technique (PDART) prior image-based suppression of high density artifacts in computed tomography
    Pua, Rizza
    Park, Miran
    Wi, Sunhee
    Cho, Seungryong
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 840 : 42 - 50
  • [43] Utilization of tin filters for streak artifact reduction in cone-beam computed tomography
    Chun, Minsoo
    Choi, Jin Hwa
    Kwon, Ohyun
    Jin, Hyeongmin
    Lee, Sung Young
    Choi, Chang Heon
    Kim, Jung-in
    Park, Jong Min
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2022, 80 (10) : 1018 - 1027
  • [44] Scatter correction for cone-beam computed tomography using moving blocker strips
    Wang, Jing
    Mao, Weihua
    Solberg, Timothy
    MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
  • [45] Adaptive Normalized Metal Artifact Reduction (ANMAR) in Computed Tomography
    Meyer, Esther
    Raupach, Rainer
    Schmidt, Bernhard
    Mahnken, Andreas H.
    Kachelriess, Marc
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 2560 - 2565
  • [46] Physics Model-Based Scatter Correction in Multi-Source Interior Computed Tomography
    Gong, Hao
    Li, Bin
    Jia, Xun
    Cao, Guohua
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2018, 37 (02) : 349 - 360
  • [47] Magnetic resonance-based computed tomography metal artifact reduction using Bayesian modelling
    Nielsen, Jonathan Scharff
    Edmund, Jens Morgenthaler
    Van Leemput, Koen
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (24)
  • [48] Nonlinearly scaled prior image-controlled frequency split for high-frequency metal artifact reduction in computed tomography
    Anhaus, Julian A.
    Killermann, Philipp
    Sedlmair, Martin
    Winter, Jonas
    Mahnken, Andreas H.
    Hofmann, Christian
    MEDICAL PHYSICS, 2022, 49 (09) : 5870 - 5885
  • [49] Hierarchical Prior-Based Super Resolution for Point Cloud Geometry Compression
    Li, Dingquan
    Ma, Kede
    Wang, Jing
    Li, Ge
    IEEE TRANSACTIONS ON IMAGE PROCESSING, 2024, 33 : 1965 - 1976
  • [50] Deep Prior-Based Unsupervised Reconstruction of Irregularly Sampled Seismic Data
    Kong, Fantong
    Picetti, Francesco
    Lipari, Vincenzo
    Bestagini, Paolo
    Tang, Xiaoming
    Tubaro, Stefano
    IEEE GEOSCIENCE AND REMOTE SENSING LETTERS, 2022, 19