Biocompatibility of rapidly solidified magnesium alloy RS66 as a temporary biodegradable metal

被引:82
|
作者
Willbold, Elmar [1 ,2 ]
Kalla, Katharina [1 ,2 ]
Bartsch, Ivonne [1 ,2 ]
Bobe, Katharina [1 ,2 ]
Brauneis, Maria [1 ,2 ]
Remennik, Sergei [3 ]
Shechtman, Dan [3 ]
Nellesen, Jens [4 ]
Tillmann, Wolfgang [4 ]
Vogt, Carla [5 ]
Witte, Frank [1 ,2 ]
机构
[1] Hannover Med Sch, Lab Biomech & Biomat, Dept Orthopaed Surg, D-30625 Hannover, Germany
[2] Hannover Med Sch, Dept Orthopaed Surg, Ctr Biocompatibil & Implant Immunol, CrossBIT, D-30625 Hannover, Germany
[3] Technion Israel Inst Technol, Dept Mat Engn, IL-32000 Haifa, Israel
[4] Tech Univ Dortmund, Inst Mat Engn, D-44227 Dortmund, Germany
[5] Leibniz Univ Hannover, Dept Inorgan Chem, D-30167 Hannover, Germany
关键词
Rapid solidification processing; RS66; Biodegradable implants; Magnesium alloy; Foreign body reaction; IN-VIVO CORROSION; BONE; DEGRADATION; IMPLANTS; VITRO; DEFICIENCY; EVOLUTION;
D O I
10.1016/j.actbio.2013.02.015
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Biodegradable magnesium-based alloys are very promising materials for temporary implants. However, the clinical use of magnesium-based alloys is often limited by rapid corrosion and by insufficient mechanical stability. Here we investigated RS66, a magnesium-based alloy with extraordinary physicochemical properties of high tensile strength combined with a high ductility and a homogeneous grain size of similar to 1 mu m which was obtained by rapid solidification processing and reciprocal extrusion. Using a series of in vitro and in vivo experiments, we analyzed the biodegradation behavior and the biocoinpatibility of this alloy. In vitro, RS66 had no cytotoxic effects in physiological concentrations on the viability and the proliferation of primary human osteoblasts. In vivo, RS66 cylinders were implanted into femur condyles, under the skin and in the muscle of adult rabbits and were monitored for 1, 2, 3, 4 and 8 weeks. After explantation, the RS66 cylinders were first analyzed by microtomography to determine the remaining RS66 alloy and calculate the corrosion rates. Then, the implantation sites were examined histologically for healing processes and foreign body reactions. We found that RS66 was corroded fastest subcutaneously followed by intramuscular and bony implantation of the samples. No clinical harm with transient gas cavities during the first 6 weeks in subcutaneous and intramuscular implantation sites was observed. No gas cavities were formed around the implantation site in bone. The corrosion rates in the different anatomical locations correlated well with the local blood flow prior to implantation. A normal foreign body reaction occurred in all tissues. Interestingly, no enhanced bone formation could be observed around the corroding samples in the condyles. These data show that RS66 is biocompatible, and due to its interesting physicochemical properties, this magnesium alloy is a promising material for biodegradable implants. (C) 2013 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:8509 / 8517
页数:9
相关论文
共 23 条
  • [21] Metal-induced artifacts in computed tomography and magnetic resonance imaging: comparison of a biodegradable magnesium alloy versus titanium and stainless steel controls
    Filli, Lukas
    Luechinger, Roger
    Frauenfelder, Thomas
    Beck, Stefan
    Guggenberger, Roman
    Farshad-Amacker, Nadja
    Andreisek, Gustav
    SKELETAL RADIOLOGY, 2015, 44 (06) : 849 - 856
  • [22] Metallic ions integrated in tannic acid (TA) as a metal-organic-like complex coating on biodegradable magnesium for enhanced corrosion control and biocompatibility
    Wang, Jiacheng
    Dou, Zhenglong
    Huang, Nan
    JOURNAL OF MATERIALS SCIENCE, 2024, 59 (38) : 18227 - 18245
  • [23] Metal-induced artifacts in computed tomography and magnetic resonance imaging: comparison of a biodegradable magnesium alloy versus titanium and stainless steel controls
    Lukas Filli
    Roger Luechinger
    Thomas Frauenfelder
    Stefan Beck
    Roman Guggenberger
    Nadja Farshad-Amacker
    Gustav Andreisek
    Skeletal Radiology, 2015, 44 : 849 - 856