摘要
A three part study was conducted to investigate the compression behavior of a built-up box column made from four cold-formed steel (CFS) channels, including an experimental program, finite element study, and evaluation of building code prediction approaches. The experimental study included fifteen box column specimens with various effective lengths and varied eccentricity. Twist and warping of the ends of the specimen were restrained. The test results indicated that the dominant failure modes were global flexural buckling, local buckling, and concentrated localized deformation caused by local buckling. A finite element (FE) study was then conducted to broaden the investigation beyond the tested configurations and it was found that varying the screw spacing from 150 mm to 450 mm has little influence on the axial compressive behavior (less than 4%) and that web height-to-thickness ratio was a key parameter affecting axial compression strength. Finally, the accuracy and applicability of the available design methods for predicting the strength of the box columns were evaluated including the "effective width method " in which the modified slenderness ratio was not considered in AISI S100-16, the "direct strength method " in AISI S100-16, the method in the Chinese building code, and the method in EN 1993-1-3. For the box columns considered in this study, the four design methods produced predictions of the concentric axial compression strength that were between -33% to +6% of the expected actual strength. The selected design methods produced the average results of eccentric axial compression strengths that were between 8% to 25% conservative as compared to the test and FEA results.
引用
收藏
页数:22
相关论文
共 50 条
  • [41] Flexural Integrity Between the Individual Channels of Built-Up Cold-Formed Steel Beams
    Suhaib, Mir Basar
    Tantray, Manzoor Ahmad
    INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2023, 23 (02) : 503 - 520
  • [42] The mechanics of built-up cold-formed steel members
    Rasmussen, Kim J. R.
    Khezri, Mani
    Schafer, Benjamin W.
    Zhang, Hao
    THIN-WALLED STRUCTURES, 2020, 154 (154)
  • [43] Behavior of concrete-filled cold-formed steel built-up section stub columns
    Chen, Man-Tai
    Zhang, Tianyi
    Young, Ben
    THIN-WALLED STRUCTURES, 2023, 187
  • [44] Flexural strength of cold-formed steel built-up box sections
    Xu, Lei
    Sultana, Papia
    Zhou, Xuhong
    THIN-WALLED STRUCTURES, 2009, 47 (6-7) : 807 - 815
  • [45] Numerical Analysis of Built-Up Cold-Formed Steel Battened Columns Subjected to Axial Compression
    Huang, Yi
    Zhao, Hongwang
    INTERNATIONAL JOURNAL OF STRUCTURAL STABILITY AND DYNAMICS, 2025,
  • [46] Experimental and numerical studies on axially restrained cold-formed steel built-up box columns at elevated temperatures
    Yang, Jingjie
    Shi, Yu
    Wang, Weiyong
    Xu, Lei
    Al-azzani, Hisham
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2020, 171
  • [47] Local-distortional interaction behaviour and design of cold-formed steel built-up columns
    Mahar, Akshay Mangal
    Jayachandran, S. Arul
    Mahendran, Mahen
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2023, 200
  • [48] Compression tests of cold-formed steel built-up T-shaped columns
    Chen, Ming
    Shen, Kai
    Lu, Wei-Bo
    Zhang, Xiang -Yu
    Shi, Yu
    Yang, Chang-Fei
    Wang, Hui-Ling
    STRUCTURES, 2023, 53 : 1172 - 1185
  • [49] Investigation on the behaviour and strength of cold-formed steel web stiffened built-up battened columns
    Anbarasu, M.
    Kanagarasu, K.
    Sukumar, S.
    MATERIALS AND STRUCTURES, 2015, 48 (12) : 4029 - 4038
  • [50] Bending response of cold-formed steel built-up beams with overlapped flanges in stiffened channels
    Dar, A. R.
    INNOVATIVE INFRASTRUCTURE SOLUTIONS, 2021, 6 (03)