An international, cross-sectional survey of the management of Vancouver type B1 periprosthetic femoral fractures around total hip arthroplasties

被引:16
作者
Bates, Brent D. [1 ]
Walmsley, David W. [2 ]
Vicente, Milena R. [2 ]
Kuzyk, Paul R. [3 ]
Nauth, Aaron [1 ,2 ]
Waddell, James P. [2 ]
McKee, Michael D. [2 ]
Schemitsch, Emil H. [4 ]
机构
[1] Univ Toronto, St Michaels Hosp, Keenan Res Ctr Biomed Sci, Toronto, ON, Canada
[2] Univ Toronto, St Michaels Hosp, Dept Surg, Div Orthopaed Surg, Toronto, ON, Canada
[3] Univ Toronto, Mt Sinai Hosp, Dept Surg, Div Orthopaed Surg, Toronto, ON, Canada
[4] Western Univ, London Hlth Sci Ctr, Dept Surg, London, ON, Canada
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2018年 / 49卷 / 02期
关键词
Total hip arthroplasty; Periprosthetic fracture; Vancouver type B1; Locking plate; Strut allograft; Survey; WELL-FIXED IMPLANTS; SHAFT FRACTURES; PLATE FIXATION; ONLAY ALLOGRAFTS; FEMUR FRACTURES; STRUT ALLOGRAFT; REDUCTION; ALGORITHM; STEM;
D O I
10.1016/j.injury.2017.10.034
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: The incidence of periprosthetic femoral fractures around total hip arthroplasties is increasing. Fractures around a stable implant stem (Vancouver type B1) are among the most common of these fractures. Various fixation strategies for Vancouver type B1 periprosthetic fractures have been reported in the literature; however, little high-level evidence exists. This study was designed to determine the current management strategies and opinions among orthopaedic surgeons treating Vancouver type B1 periprosthetic femoral fractures, and to evaluate the need for a large prospective randomized controlled trial for the management of these injuries. Methods: Orthopaedic surgeon members of the Orthopaedic Trauma Association (OTA), the Canadian Orthopaedic Association (COA), and the Hip Society were invited to participate in a 51-item web-based survey surrounding the management of periprosthetic femoral fractures around total hip replacements, as well as the perceived need for future research in this area. Responses were summarized using proportions, and further stratified by practice type, case volume, surgeon age, and fellowship training. Results: For Vancouver type B1 fractures, open reduction and internal fixation (ORIF) with locked plating was favoured slightly over ORIF with cable plating +/- cortical strut allograft (51.1% versus 45.5%). When compared to cable plating with cortical strut allograft, respondents believed that isolated locked plating resulted in lower nonunion and reoperation rates, but similar infection and malunion rates. Subgroup analyses revealed that practice type, surgeon age, case volume, and fellowship training influenced surgeons' management of periprosthetic femoral fractures and beliefs regarding complications. There is high demand for a large prospective randomized controlled trial for Vancouver type B1 fracture fixation. Conclusions: Consensus surrounding the management of Vancouver type B1 periprosthetic femoral fractures is lacking, and there is a perceived need among orthopaedic surgeons for a large prospective randomized controlled trial in order to define the optimal management of these injuries. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:364 / 369
页数:6
相关论文
共 48 条
  • [21] Locking plate osteosynthesis for Vancouver Type B1 and Type C periprosthetic fractures of femur: A report on 12 patients
    Chakravarthy, Jagannath
    Bansal, Rajeev
    Cooper, Julian
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2007, 38 (06): : 725 - 733
  • [22] Impact of bone health on the mechanics of plate fixation for Vancouver B1 periprosthetic femoral fractures
    Chen, Xiang
    Myers, Casey A.
    Clary, Chadd W.
    Varga, Peter
    Coombs, Dana
    DeWall, Ryan J.
    Fritz, Bryan
    Rullkoetter, Paul J.
    CLINICAL BIOMECHANICS, 2022, 100
  • [23] Locking Compression Plate and Cerclage Band for Type B1 Periprosthetic Femoral Fractures
    Xue, Huaming
    Tu, Yihui
    Cai, Minwei
    Yang, Anli
    JOURNAL OF ARTHROPLASTY, 2011, 26 (03) : 467 - 471
  • [24] Principles of managing Vancouver type B periprosthetic fractures around cemented polished tapered femoral stems
    Quah C.
    Porteous M.
    Stephen A.
    European Journal of Orthopaedic Surgery & Traumatology, 2017, 27 (4) : 477 - 482
  • [25] Contribution of the remaining attachment index in the management of Vancouver B1 periprosthetic hip fracture
    Andriamananaivo, Tsiry
    Odri, Guillaume-Anthony
    Ollivier, Matthieu
    Mattesi, Lucas
    Renault, Arthur
    Rongieras, Frederic
    Pesenti, Sebastien
    Severyns, Mathieu
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2020, 106 (07) : 1413 - 1417
  • [26] The management of Vancouver B1 and C periprosthetic fractures: radiographic and clinic outcomes of a monocentric consecutive series
    Ciriello, Vincenzo
    Chiarpenello, Roberto
    Tomarchio, Alessandro
    Marra, Francesco
    Egidio, Antonio Carmine
    Piovani, Lucio
    HIP INTERNATIONAL, 2020, 30 (2_SUPPL) : 94 - 100
  • [27] Management of Vancouver B2 Periprosthetic Femoral Fractures, Revision Total Hip Arthroplasty Versus Open Reduction and Internal Fixation: A Systematic Review and Meta-Analysis
    Lewis, Daniel P.
    Tarrant, Seth M.
    Cornford, Lachlan
    Balogh, Zsolt J.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2022, 36 (01) : 7 - 16
  • [28] Plain films are not accurate in planning internal fixation in vancouver type B1 periprosthetic femoral fractures and in distinguishing between subtypes B1 And B2
    Cinotti, Gianluca
    Sinno, Ennio
    Fornara, Gianluca
    LaTorre, Giuseppe
    Giannicola, Giuseppe
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2021, 52 (06): : 1592 - 1596
  • [29] Results of Utilizing Cerclage Wires in the Management of Intraoperative Vancouver B1 Fractures in Primary Total Hip Arthroplasties: A Retrospective Cohort Investigation into Clinical and Radiographic Outcomes
    Rocchi, Caterina
    Di Matteo, Vincenzo
    Chiappetta, Katia
    Grappiolo, Guido
    Loppini, Mattia
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (03)
  • [30] Double plating in Vancouver type B1 periprosthetic proximal femur fractures: A biomechanical study
    Waehnert, Dirk
    Grueneweller, Niklas
    Gehweiler, Dominic
    Brunn, Benjamin
    Raschke, Michael J.
    Stange, Richard
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2017, 35 (02) : 234 - 239