Optimal observation time after completion of circumferential pulmonary vein isolation for atrial fibrillation to prevent chronic pulmonary vein reconnections

被引:15
作者
Nakamura, Kohki [1 ]
Naito, Shigeto [1 ]
Kaseno, Kenichi [1 ]
Tsukada, Naofumi [1 ]
Sasaki, Takehito [1 ]
Hayano, Mamoru [1 ]
Nishiuchi, Suguru [1 ]
Fuke, Etsuko [1 ]
Miki, Yuko [1 ]
Sakamoto, Tamotsu [1 ]
Nakamura, Keijiro [1 ]
Kumagai, Koji [1 ]
Kataoka, Akihisa [2 ]
Takaoka, Hiroyuki [2 ]
Kobayashi, Yoshio [2 ]
Funabashi, Nobusada [2 ]
Oshima, Shigeru [1 ]
机构
[1] Gunma Prefectural Cardiovasc Ctr, Div Cardiol, Maebashi, Gunma 3710004, Japan
[2] Chiba Univ, Grad Sch Med, Dept Cardiovasc Med, Chuo Ku, Chiba 2608670, Japan
关键词
Optimal observation time; Circumferential pulmonary vein isolation; Atrial fibrillation; Chronic pulmonary vein reconnections; CATHETER ABLATION; ADENOSINE-TRIPHOSPHATE; WALL THICKNESS; CONDUCTION; RECURRENCE; EFFICACY; RESUMPTION; LESSONS; LESIONS; IMPACT;
D O I
10.1016/j.ijcard.2013.08.011
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: To identify predictors of chronic pulmonary vein (PV) reconnection (CPVR) after successful circumferential PV isolation (CPVI) for atrial fibrillation (AF). Materials and methods: A total of 718 PVs from 181 consecutive AF patients (141 males, median age 61 years, 92 paroxysmal AF) who underwent a second ablation procedure for recurrent AF were retrospectively analyzed. Results: During the second procedure, a CPVRwas observed in 477 PVs (66.4%) among 169 patients. In a multiple logistic regression analysis, the observation time after the final completion of the PVI (OT-final) was a significant negative predictor (odds ratio 0.980; P < 0.001). A receiver operating characteristic analysis demonstrated that the greatest area under the curve was for the OT-final (0.670). At an optimal cutoff of 35 min, the sensitivity and specificity for predicting a CPVR were 66.9% and 60.6%, respectively. By Kaplan Meier analysis, CPVR was more frequent in PVs with an OT-final of b35 min than = 35 min (log-rank test, P = 0.018). In a vessel-by-vessel analysis, the OT-final at all PV sites was a significant negative predictor, while male gender in the right PVs and left-inferior PV, number of RF applications for the ipsilateral CPVI in the right PVs and left-superior PV, and major PV diameter in the left-superior PV were significant positive predictors of a CPVR (all P < 0.05). Conclusions: An optimal observation time (>= 35 min in this study) to determinewhether PVI is successfully completed during the initial CPVI for AFmay be needed to prevent a CPVR and subsequent AF recurrence thereafter. (C) 2013 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:5300 / 5310
页数:11
相关论文
共 32 条
  • [21] Pulmonary vein isolation for paroxysmal and persistent atrial fibrillation
    Oral, H
    Knight, BP
    Tada, H
    Özaydin, M
    Chugh, A
    Hassan, S
    Scharf, C
    Lai, SWK
    Greenstein, R
    Pelosi, F
    Strickberger, SA
    Morady, F
    [J]. CIRCULATION, 2002, 105 (09) : 1077 - 1081
  • [22] Long-Term Results of Catheter Ablation in Paroxysmal Atrial Fibrillation Lessons From a 5-Year Follow-Up
    Ouyang, Feifan
    Tilz, Roland
    Chun, Julian
    Schmidt, Boris
    Wissner, Erik
    Zerm, Thomas
    Neven, Kars
    Koektuerk, Bulent
    Konstantinidou, Melanie
    Metzner, Andreas
    Fuernkranz, Alexander
    Kuck, Karl-Heinz
    [J]. CIRCULATION, 2010, 122 (23) : 2368 - 2377
  • [23] Recovered pulmonary vein conduction as a dominant factor for recurrent atrial tachyarrhythmias after complete circular isolation of the pulmonary veins -: Lessons from double lasso technique
    Ouyang, FF
    Antz, M
    Ernst, S
    Hachiya, H
    Mavrakis, H
    Deger, FT
    Schaumann, A
    Chun, J
    Falk, P
    Hennig, D
    Liu, XP
    Bänsch, D
    Kuck, KH
    [J]. CIRCULATION, 2005, 111 (02) : 127 - 135
  • [24] Complete isolation of left atrium surrounding the pulmonary veins -: New insights from the double-lasso technique in paroxysmal atrial fibrillation
    Ouyang, FF
    Bänsch, D
    Ernst, S
    Schaumann, A
    Hachiya, H
    Chen, ML
    Chun, JL
    Falk, P
    Khanedani, A
    Antz, M
    Kuck, KH
    [J]. CIRCULATION, 2004, 110 (15) : 2090 - 2096
  • [25] Left atrial posterior wall thickness in patients with and without atrial fibrillation: Data from 298 consecutive autopsies
    Platonov, Pyotr G.
    Ivanov, Vitaly
    Ho, Siew Yen
    Mitrofanova, Lubov
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2008, 19 (07) : 689 - 692
  • [26] Acute and Chronic Pulmonary Vein Reconnection after Atrial Fibrillation Ablation: A Prospective Characterization of Anatomical Sites
    Rajappan, Kim
    Kistler, Peter M.
    Earley, Mark J.
    Thomas, Glyn
    Izquierdo, Maite
    Sporton, Simon C.
    Schilling, Richard J.
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2008, 31 (12): : 1598 - 1605
  • [27] Clinical predictors and outcomes associated with acute return of pulmonary vein conduction during pulmonary vein isolation for treatment of atrial fibrillation
    Sauer, William H.
    McKernan, Melissa L.
    Lin, David
    Gerstenfeld, Edward P.
    Callans, David J.
    Marchlinski, Francis E.
    [J]. HEART RHYTHM, 2006, 3 (09) : 1024 - 1028
  • [28] Catheter Ablation of Long-Standing Persistent Atrial Fibrillation: A Lesson from Circumferential Pulmonary Vein Isolation
    Tilz, Roland Richard
    Chun, K. R. Julian
    Schmidt, Boris
    Fuernkranz, Alexander
    Wissner, Erik
    Koester, Ilka
    Baensch, Dietmar
    Boczor, Sigrid
    Koektuerk, Buelent
    Metzner, Andreas
    Zerm, Thomas
    Ernst, Sabine
    Antz, Matthias
    Kuck, Karl-Heinz
    Ouyang, Feifan
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2010, 21 (10) : 1085 - 1093
  • [29] Response of atrial fibrillation to pulmonary vein antrum isolation is directly related to resumption and delay of pulmonary vein conduction
    Verma, A
    Kilicaslan, F
    Pisano, E
    Marrouche, NF
    Fanelli, R
    Brachmann, J
    Geunther, J
    Potenza, D
    Martin, DO
    Cummings, J
    Burkhardt, JD
    Saliba, W
    Schweikert, RA
    Natale, A
    [J]. CIRCULATION, 2005, 112 (05) : 627 - 635
  • [30] Early identification and treatment of PV re-connections: role of observation time and impact on clinical results of atrial fibrillation ablation
    Wang, Xin-Hua
    Liu, Xu
    Sun, Yu-Min
    Gu, Jia-Ning
    Shi, Hai-Feng
    Zhou, Li
    Hu, Wei
    [J]. EUROPACE, 2007, 9 (07): : 481 - 486