Projections onto the Pareto surface in multicriteria radiation therapy optimization

被引:14
作者
Bokrantz, Rasmus [1 ,2 ]
Miettinen, Kaisa [1 ,3 ]
机构
[1] KTH Royal Inst Technol, Optimizat & Syst Theory, Dept Math, SE-10044 Stockholm, Sweden
[2] RaySearch Labs, SE-10365 Stockholm, Sweden
[3] Univ Jyvaskyla, Dept Math Informat Technol, FI-40014 Jyvaskyla, Finland
关键词
multicriteria; Pareto optimality; projection; radiation therapy; optimization; MULTIPLE LOCAL MINIMA; IMRT; DECOMPOSITION; DISTRIBUTIONS; PLANS;
D O I
10.1118/1.4930252
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To eliminate or reduce the error to Pareto optimality that arises in Pareto surface navigation when the Pareto surface is approximated by a small number of plans. Methods: The authors propose to project the navigated plan onto the Pareto surface as a postprocessing step to the navigation. The projection attempts to find a Pareto optimal plan that is at least as good as or better than the initial navigated plan with respect to all objective functions. An augmented form of projection is also suggested where dose-volume histogram constraints are used to prevent that the projection causes a violation of some clinical goal. The projections were evaluated with respect to planning for intensity modulated radiation therapy delivered by step-and-shoot and sliding window and spot-scanned intensity modulated proton therapy. Retrospective plans were generated for a prostate and a head and neck case. Results: The projections led to improved dose conformity and better sparing of organs at risk (OARs) for all three delivery techniques and both patient cases. The mean dose to OARs decreased by 3.1 Gy on average for the unconstrained form of the projection and by 2.0 Gy on average when dose-volume histogram constraints were used. No consistent improvements in target homogeneity were observed. Conclusions: There are situations when Pareto navigation leaves room for improvement in OAR sparing and dose conformity, for example, if the approximation of the Pareto surface is coarse or the problem formulation has too permissive constraints. A projection onto the Pareto surface can identify an inaccurate Pareto surface representation and, if necessary, improve the quality of the navigated plan. (C) 2015 American Association of Physicists in Medicine.
引用
收藏
页码:5862 / 5870
页数:9
相关论文
共 33 条
[1]   COLLAPSED CONE CONVOLUTION OF RADIANT ENERGY FOR PHOTON DOSE CALCULATION IN HETEROGENEOUS MEDIA [J].
AHNESJO, A .
MEDICAL PHYSICS, 1989, 16 (04) :577-592
[2]  
[Anonymous], 2012, CISC VIS NETW IND GL
[3]  
[Anonymous], 2013, AM SOC CIVIL ENG
[4]  
[Anonymous], 2010, J ICRU, DOI [10.1093/jicru_ndq002, DOI 10.1093/JICRU_NDQ002]
[5]   Distributed approximation of Pareto surfaces in multicriteria radiation therapy treatment planning [J].
Bokrantz, Rasmus .
PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (11) :3501-3516
[6]   An Algorithm for Approximating Convex Pareto Surfaces Based on Dual Techniques [J].
Bokrantz, Rasmus ;
Forsgren, Anders .
INFORMS JOURNAL ON COMPUTING, 2013, 25 (02) :377-393
[7]   Multicriteria optimization for volumetric-modulated arc therapy by decomposition into a fluence-based relaxation and a segment weight-based restriction [J].
Bokrantz, Rasmus .
MEDICAL PHYSICS, 2012, 39 (11) :6712-6725
[8]   DECOMPOSITION OF PENCIL BEAM KERNELS FOR FAST DOSE CALCULATIONS IN 3-DIMENSIONAL TREATMENT PLANNING [J].
BORTFELD, T ;
SCHLEGEL, W ;
RHEIN, B .
MEDICAL PHYSICS, 1993, 20 (02) :311-318
[9]   A comparison of two reference point methods in multiple objective mathematical programming [J].
Buchanan, J ;
Gardiner, L .
EUROPEAN JOURNAL OF OPERATIONAL RESEARCH, 2003, 149 (01) :17-34
[10]   How many plans are needed in an IMRT multi-objective plan database? [J].
Craft, David ;
Bortfeld, Thomas .
PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (11) :2785-2796