Evaluation of Image Quality for 7 Iterative Reconstruction Algorithms in Chest Computed Tomography Imaging: A Phantom Study

被引:9
作者
Jensen, Kristin [1 ,2 ]
Hagemo, Guro [3 ]
Tingberg, Anders [4 ]
Steinfeldt-Reisse, Claudius [5 ]
Mynarek, Georg Karl [5 ]
Rivero, Rodriguez Jezabel [6 ]
Fosse, Erik [7 ,8 ]
Martinsen, Anne Catrine [1 ,2 ]
机构
[1] Oslo Univ Hosp, Dept Diagnost Phys, Oslo, Norway
[2] Univ Oslo, Dept Phys, Oslo, Norway
[3] Oslo Univ Hosp, Radiumhospitalet, Dept Radiol & Nucl Med, Oslo, Norway
[4] Lund Univ, Skane Univ Hosp, Dept Med Radiat Phys, Malmo, Sweden
[5] Oslo Univ Hosp, Rikshosp, Dept Radiol & Nucl Med, Oslo, Norway
[6] Oslo Univ Hosp, Dept Radiol & Nucl Med, Ulleval, Oslo, Norway
[7] Natl Hosp Norway, Intervent Ctr, Oslo, Norway
[8] Univ Oslo, Inst Clin Med, Oslo, Norway
关键词
computed tomography; image reconstruction; radiologic phantom; thorax; LOW-CONTRAST DETECTABILITY; RADIATION-DOSE REDUCTION; FILTERED BACK-PROJECTION; MODERN DIAGNOSTIC MDCT; NOISE POWER SPECTRUM; ABDOMINAL CT; PULMONARY NODULES; STANDARD; RESOLUTION; HYBRID;
D O I
10.1097/RCT.0000000000001037
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives This study aimed to evaluate the image quality of 7 iterative reconstruction (IR) algorithms in comparison to filtered back-projection (FBP) algorithm. Methods An anthropomorphic chest phantom was scanned on 4 computed tomography scanners and reconstructed with FBP and IR algorithms. Image quality of anatomical details-large/medium-sized pulmonary vessels, small pulmonary vessels, thoracic wall, and small and large lesions-was scored. Furthermore, general impression of noise, image contrast, and artifacts were evaluated. Visual grading regression was used to analyze the data. Standard deviations were measured, and the noise power spectrum was calculated. Results Iterative reconstruction algorithms showed significantly better results when compared with FBP for these criteria (regression coefficients/Pvalues in parentheses): vessels (FIRST: -1.8/0.05, AIDR Enhanced: <-2.3/0.01, Veo: <-0.1/0.03, ADMIRE: <-2.1/0.04), lesions (FIRST: <-2.6/0.01, AIDR Enhanced: <-1.9/0.03, IMR1: <-2.7/0.01, Veo: <-2.4/0.02, ADMIRE: -2.3/0.02), image noise (FIRST: <-3.2/0.004, AIDR Enhanced: <-3.5/0.002, IMR1: <-6.1/0.001, iDose: <-2.3/0.02, Veo: <-3.4/0.002, ADMIRE: <-3.5/0.02), image contrast (FIRST: -2.3/0.01, AIDR Enhanced: -2.5/0.01, IMR1: -3.7/0.001, iDose: -2.1/0.02), and artifacts (FIRST: <-3.8/0.004, AIDR Enhanced: <-2.7/0.02, IMR1: <-2.6/0.02, iDose: -2.1/0.04, Veo: -2.6/0.02). The iDose algorithm was the only IR algorithm that maintained the noise frequencies. Conclusions Iterative reconstruction algorithms performed differently on all evaluated criteria, showing the importance of careful implementation of algorithms for diagnostic purposes.
引用
收藏
页码:673 / 680
页数:8
相关论文
共 64 条
[51]   Visual grading regression: analysing data from visual grading experiments with regression models [J].
Smedby, O. ;
Fredrikson, M. .
BRITISH JOURNAL OF RADIOLOGY, 2010, 83 (993) :767-775
[52]   Diagnostic Performance of an Advanced Modeled Iterative Reconstruction Algorithm for Low-Contrast Detectability with a Third-Generation Dual-Source Multidetector CT Scanner: Potential for Radiation Dose Reduction in a Multireader Study [J].
Solomon, Justin ;
Mileto, Achille ;
Ramirez-Giraldo, Juan Carlos ;
Samei, Ehsan .
RADIOLOGY, 2015, 275 (03) :735-745
[53]   Can fully iterative reconstruction technique enable routine abdominal CT at less than 1 mSv? [J].
Tabari, Azadeh ;
Singh, Ramandeep ;
Khera, Ruhani Doda ;
Hoi, Yiemeng ;
Angel, Erin ;
Kalra, Mannudeep K. ;
Madan, Rachna .
EUROPEAN JOURNAL OF RADIOLOGY OPEN, 2019, 6 :225-230
[54]   Clinical value of a new generation adaptive statistical iterative reconstruction (ASIR-V) in the diagnosis of pulmonary nodule in low-dose chest CT [J].
Tang, Hui ;
Liu, Zhentang ;
Hu, Zhijun ;
He, Taiping ;
Li, Dou ;
Yu, Nan ;
Jia, Yongjun ;
Shi, Hong .
BRITISH JOURNAL OF RADIOLOGY, 2019, 92 (1103)
[55]  
Thibault JB, 2011, MODEL BASED PARADIGM
[56]   A three-dimensional statistical approach to improved image quality for multislice helical CT [J].
Thibault, Jean-Baptiste ;
Sauer, Ken D. ;
Bouman, Charles A. ;
Hsieh, Jiang .
MEDICAL PHYSICS, 2007, 34 (11) :4526-4544
[57]   Effect of reconstruction methods and x-ray tube current-time product on nodule detection in an anthropomorphic thorax phantom: A crossed-modality JAFROC observer study [J].
Thompson, J. D. ;
Chakraborty, D. P. ;
Szczepura, K. ;
Tootell, A. K. ;
Vamvakas, I. ;
Manning, D. J. ;
Hogg, P. .
MEDICAL PHYSICS, 2016, 43 (03) :1265-1274
[58]  
Van der Velden L, 2017, TECHNICAL CLIN ANAL
[59]   Prospective intra-individual comparison of standard dose versus reduced-dose thoracic CT using hybrid and pure iterative reconstruction in a follow-up cohort of pulmonary nodules-Effect of detectability of pulmonary nodules with lowering dose based on nodule size, type and body mass index [J].
Vardhanabhuti, Varut ;
Pang, Chun-Lap ;
Tenant, Sean ;
Taylor, James ;
Hyde, Christopher ;
Roobottom, Carl .
EUROPEAN JOURNAL OF RADIOLOGY, 2017, 91 :130-141
[60]   Image quality in CT: From physical measurements to model observers [J].
Verdun, F. R. ;
Racine, D. ;
Ott, J. G. ;
Tapiovaara, M. J. ;
Toroi, P. ;
Bochud, F. O. ;
Veldkamp, W. J. H. ;
Schegerer, A. ;
Bouwman, R. W. ;
Giron, I. Hernandez ;
Marshall, N. W. ;
Edyvean, S. .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (08) :823-843