Amplitude-Integrated Electroencephalography in the NICU: Frequent Artifacts in Premature Infants May Limit Its Utility as a Monitoring Device

被引:20
|
作者
Suk, Debbie
Krauss, Alfred N.
Engel, Murray
Perlman, Jeffrey M. [1 ]
机构
[1] Cornell Univ, Weill Cornell Med Coll, Dept Pediat, New York, NY 10065 USA
关键词
premature infant; cerebral function monitor; amplitude-integrated electroencephalography; raw electroencephalogram; artifact; NEONATAL ENCEPHALOPATHY; MATURATION; NEWBORN; EEG;
D O I
10.1542/peds.2008-2850
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
BACKGROUND. Amplitude-integrated electroencephalography has become an important tool for assessing cortical status noninvasively. Newer units have the additional feature of visualizing the raw electroencephalogram, which has resulted in the identification of frequent artifacts. OBJECTIVE. To highlight the problem of artifacts and to introduce caution when using the amplitude-integrated electroencephalography technique to assess cortical function in the premature population. METHODS. Ten premature infants were evaluated. Compressed amplitude-integrated electroencephalography recordings were made by using a pair of standard electroencephalogram electrodes attached to the scalp frontotemporal areas. Impedance was maintained at < 10 k Omega. Continuous amplitude-integrated electroencephalography recordings were performed for at least 60 minutes on several occasions in the first month. Artifacts were identified as follows: large amplitude difference between the wave peaks and troughs, a jagged appearance to wave peaks and troughs, and large deflections of the overall tracing in either a positive or negative direction from baseline. RESULTS. Forty-eight amplitude-integrated electroencephalography recordings were reviewed. Of 1683 total segments analyzed, 529 (31.4%) were categorized as normal brain waves, 1013 (60.2%) as artifacts, and 142 (8.4%) as indeterminate. Generally, when the amplitude-integrated electroencephalography tracing is of modest amplitude, normal brain waves predominated, whereas with upward spikes in amplitude the accompanying raw electroencephalogram was classified as artifact. CONCLUSIONS. Artifacts contribute substantially to the amplitude-integrated electroencephalography tracing, rendering it problematic as an assessment tool in premature infants. Artifacts may be influenced by muscle activity, electrode positioning, and application techniques. Caution is recommended when using amplitude-integrated electroencephalography as an assessment tool in this population. Pediatrics 2009; 123: e328-e332
引用
收藏
页码:E328 / E332
页数:5
相关论文
共 4 条
  • [1] The Role of Amplitude-Integrated Electroencephalography (aEEG) in Monitoring Infants with Neonatal Seizures and Predicting Their Neurodevelopmental Outcome
    Doandes, Florina Marinela
    Manea, Aniko Maria
    Lungu, Nicoleta
    Brandibur, Timea
    Cioboata, Daniela
    Costescu, Oana Cristina
    Zaharie, Mihaela
    Boia, Marioara
    CHILDREN-BASEL, 2023, 10 (05):
  • [2] Early abnormal amplitude-integrated electroencephalography (aEEG) is associated with adverse short-term outcome in premature infants
    Soubasi, Vassiliki
    Mitsakis, Konstantinos
    Sarafidis, Kosmas
    Griva, Myrsini
    Nakas, Christos T.
    Drossou, Vassiliki
    EUROPEAN JOURNAL OF PAEDIATRIC NEUROLOGY, 2012, 16 (06) : 625 - 630
  • [3] Discrimination of sleep states using continuous cerebral bedside monitoring (amplitude-integrated electroencephalography) compared to polysomnography in infants
    Bennet, Laura
    Fyfe, Karinna L.
    Yiallourou, Stephanie R.
    Merk, Henriette
    Wong, Flora Y.
    Horne, Rosemary S. C.
    ACTA PAEDIATRICA, 2016, 105 (12) : E582 - E587
  • [4] Evaluation of Preoperative Amplitude-Integrated Electroencephalography (aEEG) Monitoring for Predicting Long-Term Neurodevelopmental Outcome Among Infants Undergoing Major Surgery in the Neonatal Period
    Mehta, Bhavesh
    Hunt, Rodney
    Walker, Karen
    Badawi, Nadia
    JOURNAL OF CHILD NEUROLOGY, 2016, 31 (11) : 1276 - 1281