Investigation of gated cone-beam CT to reduce respiratory motion blurring

被引:17
|
作者
Kincaid, Russell E., Jr. [1 ]
Yorke, Ellen D. [1 ]
Goodman, Karyn A. [2 ]
Rimner, Andreas [2 ]
Wu, Abraham J. [2 ]
Mageras, Gig S. [1 ]
机构
[1] Mem Sloan Kettering Canc Ctr, Dept Med Phys, New York, NY 10065 USA
[2] Mem Sloan Kettering Canc Ctr, Dept Radiat Oncol, New York, NY 10065 USA
关键词
image guided radiation therapy; cone-beam CT; respiratory motion; motion management; 4-DIMENSIONAL COMPUTED-TOMOGRAPHY; RADIATION-THERAPY; LUNG-TUMORS; QUALITY-ASSURANCE; CANCER; LIVER;
D O I
10.1118/1.4795336
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Methods of reducing respiratory motion blurring in cone-beam CT (CBCT) have been limited to lung where soft tissue contrast is large. Respiration-correlated cone-beam CT uses slow continuous gantry rotation but image quality is limited by uneven projection spacing. This study investigates the efficacy of a novel gated CBCT technique. Methods: In gated CBCT, the linac is programmed such that gantry rotation and kV image acquisition occur within a gate around end expiration and are triggered by an external respiratory monitor. Standard CBCT and gated CBCT scans are performed in 22 patients (11 thoracic, 11 abdominal) and a respiration-correlated CT (RCCT) scan, acquired on a standard CT scanner, from the same day serves as a criterion standard. Image quality is compared by calculating contrast-to-noise ratios (CNR) for tumors in lung, gastroesophageal junction (GEJ) tissue, and pancreas tissue, relative to surrounding background tissue. Congruence between the object in the CBCT images and that in the RCCT is measured by calculating the optimized normalized cross-correlation (NCC) following CBCT-to-RCCT rigid registrations. Results: Gated CBCT results in reduced motion artifacts relative to standard CBCT, with better visualization of tumors in lung, and of abdominal organs including GEJ, pancreas, and organs at risk. CNR of lung tumors is larger in gated CBCT in 6 of 11 cases relative to standard CBCT. A paired two-tailed t-test of lung patient mean CNR shows no statistical significance (p = 0.133). In 4 of 5 cases where CNR is not increased, lung tumor motion observed in RCCT is small (range 1.3-5.2 mm). CNR is increased and becomes statistically significant for 6 out of 7 lung patients with > 5 mm tumor motion (p = 0.044). CNR is larger in gated CBCT in 5 of 7 GEE cases and 3 of 4 pancreas cases (p = 0.082 and 0.192). Gated CBCT yields improvement with lower NCC relative to standard CBCT in 10 of 11, 7 of 7, and 3 of 4 patients for lung, GEJ, and pancreas images, respectively (p = 0.0014, 0.0030, 0.165). Conclusions: Gated CBCT reduces image blurring caused by respiratory motion. The gated gantry rotation yields uniformly and closely spaced projections resulting in improved reconstructed image quality. The technique is shown to be applicable to abdominal sites, where image contrast of soft tissues is low. (C) 2013 American Association of Physicists in Medicine. [http ://dx.doi.org/10.1118/1.4795336]
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Targeted Deformable Motion Compensation for Vascular Interventional Cone-Beam CT Imaging
    Sisniega, A.
    Lu, A.
    Huang, H.
    Zbijewski, W.
    Unberath, M.
    Siewerdsen, J. H.
    Weiss, C. R.
    MEDICAL IMAGING 2022: PHYSICS OF MEDICAL IMAGING, 2022, 12031
  • [22] Image-based deformable motion compensation for interventional cone-beam CT
    Sisniega, A.
    Capostagno, S.
    Zbijewski, W.
    Weiss, C. R.
    Ehtiati, T.
    Siewerdsen, J. H.
    MEDICAL IMAGING 2019: PHYSICS OF MEDICAL IMAGING, 2019, 10948
  • [23] A Validation Framework for Head-Motion Artifacts in Dental Cone-Beam CT
    Ens, S.
    Bruder, R.
    Ulrici, J.
    Hell, E.
    Buzug, T. M.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 2 - DIAGNOSTIC IMAGING, 2009, 25 : 658 - 661
  • [24] Workflow and performance of intraoperative CT, cone-beam CT, and robotic cone-beam CT for spinal navigation in 503 consecutive patients
    Kendlbacher, Paul
    Tkatschenko, Dimitri
    Czabanka, Marcus
    Bayerl, Simon
    Bohner, Georg
    Woitzik, Johannes
    Vajkoczy, Peter
    Hecht, Nils
    NEUROSURGICAL FOCUS, 2022, 52 (01)
  • [25] Evaluation of respiratory motion-corrected cone-beam CT at end expiration in abdominal radiotherapy sites: a prospective study
    Kincaid, Russell E., Jr.
    Hertanto, Agung E.
    Hu, Yu-Chi
    Wu, Abraham J.
    Goodman, Karyn A.
    Pham, Hai D.
    Yorke, Ellen D.
    Zhang, Qinghui
    Chen, Qing
    Mageras, Gig S.
    ACTA ONCOLOGICA, 2018, 57 (08) : 1017 - 1024
  • [26] CT Thermometry for Cone-beam CT Guided Ablation
    DeStefano, Zachary
    Abi-Jaoudeh, Nadine
    Li, Ming
    Wood, Bradford J.
    Summers, Ronald M.
    Yao, Jianhua
    MEDICAL IMAGING 2016: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2016, 9786
  • [27] A new strategy for online adaptive prostate radiotherapy based on cone-beam CT
    Boggula, Ramesh
    Lorenz, Friedlieb
    Abo-Madyan, Yasser
    Lohr, Frank
    Wolff, Dirk
    Boda-Heggemann, Judit
    Hesser, Juergen
    Wenz, Frederik
    Wertz, Hansjoerg
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2009, 19 (04): : 264 - 276
  • [28] Fast shading correction for cone-beam CT via partitioned tissue classification
    Shi, Linxi
    Wang, Adam
    Wei, Jikun
    Zhu, Lei
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (06):
  • [29] Modeling and measurement of the variations of CT number distributions for mobile targets in cone-beam computed tomographic imaging
    Ali, Imad
    Alsbou, Nesreen
    Ahmad, Salahuddin
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (01): : 360 - 372
  • [30] Motion compensated cone-beam CT reconstruction using an a priori motion model from CT simulation: a pilot study
    Lauria, Michael
    Miller, Claudia
    Singhrao, Kamal
    Lewis, John
    Lin, Weicheng
    O'Connell, Dylan
    Naumann, Louise
    Stiehl, Bradley
    Santhanam, Anand
    Boyle, Peter
    Raldow, Ann C.
    Goldin, Jonathan
    Barjaktarevic, Igor
    Low, Daniel A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (07):