Investigation of gated cone-beam CT to reduce respiratory motion blurring

被引:17
|
作者
Kincaid, Russell E., Jr. [1 ]
Yorke, Ellen D. [1 ]
Goodman, Karyn A. [2 ]
Rimner, Andreas [2 ]
Wu, Abraham J. [2 ]
Mageras, Gig S. [1 ]
机构
[1] Mem Sloan Kettering Canc Ctr, Dept Med Phys, New York, NY 10065 USA
[2] Mem Sloan Kettering Canc Ctr, Dept Radiat Oncol, New York, NY 10065 USA
关键词
image guided radiation therapy; cone-beam CT; respiratory motion; motion management; 4-DIMENSIONAL COMPUTED-TOMOGRAPHY; RADIATION-THERAPY; LUNG-TUMORS; QUALITY-ASSURANCE; CANCER; LIVER;
D O I
10.1118/1.4795336
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Methods of reducing respiratory motion blurring in cone-beam CT (CBCT) have been limited to lung where soft tissue contrast is large. Respiration-correlated cone-beam CT uses slow continuous gantry rotation but image quality is limited by uneven projection spacing. This study investigates the efficacy of a novel gated CBCT technique. Methods: In gated CBCT, the linac is programmed such that gantry rotation and kV image acquisition occur within a gate around end expiration and are triggered by an external respiratory monitor. Standard CBCT and gated CBCT scans are performed in 22 patients (11 thoracic, 11 abdominal) and a respiration-correlated CT (RCCT) scan, acquired on a standard CT scanner, from the same day serves as a criterion standard. Image quality is compared by calculating contrast-to-noise ratios (CNR) for tumors in lung, gastroesophageal junction (GEJ) tissue, and pancreas tissue, relative to surrounding background tissue. Congruence between the object in the CBCT images and that in the RCCT is measured by calculating the optimized normalized cross-correlation (NCC) following CBCT-to-RCCT rigid registrations. Results: Gated CBCT results in reduced motion artifacts relative to standard CBCT, with better visualization of tumors in lung, and of abdominal organs including GEJ, pancreas, and organs at risk. CNR of lung tumors is larger in gated CBCT in 6 of 11 cases relative to standard CBCT. A paired two-tailed t-test of lung patient mean CNR shows no statistical significance (p = 0.133). In 4 of 5 cases where CNR is not increased, lung tumor motion observed in RCCT is small (range 1.3-5.2 mm). CNR is increased and becomes statistically significant for 6 out of 7 lung patients with > 5 mm tumor motion (p = 0.044). CNR is larger in gated CBCT in 5 of 7 GEE cases and 3 of 4 pancreas cases (p = 0.082 and 0.192). Gated CBCT yields improvement with lower NCC relative to standard CBCT in 10 of 11, 7 of 7, and 3 of 4 patients for lung, GEJ, and pancreas images, respectively (p = 0.0014, 0.0030, 0.165). Conclusions: Gated CBCT reduces image blurring caused by respiratory motion. The gated gantry rotation yields uniformly and closely spaced projections resulting in improved reconstructed image quality. The technique is shown to be applicable to abdominal sites, where image contrast of soft tissues is low. (C) 2013 American Association of Physicists in Medicine. [http ://dx.doi.org/10.1118/1.4795336]
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Image quality of cone beam CT on respiratory motion
    ZHANG Ke1 LI Minghui1 DAI Jianrong1
    NuclearScienceandTechniques, 2011, 22 (02) : 111 - 117
  • [2] Image quality of cone beam CT on respiratory motion
    Zhang Ke
    Li Minghui
    Da Jianrong
    Wang Shi
    NUCLEAR SCIENCE AND TECHNIQUES, 2011, 22 (02) : 111 - 117
  • [3] Five-Dimensional Motion Compensation for Respiratory and Cardiac Motion with Cone-Beam CT of the Thorax Region
    Sauppe, Sebastian
    Hahn, Andreas
    Brehm, Marcus
    Paysan, Pascal
    Seghers, Dieter
    Kachelriess, Marc
    MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
  • [4] Deformable motion compensation for interventional cone-beam CT
    Capostagno, S.
    Sisniega, A.
    Stayman, J. W.
    Ehtiati, T.
    Weiss, C. R.
    Siewerdsen, J. H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (05):
  • [5] Respiratory signal generation for retrospective gating of cone-beam CT images
    Wiesner, Stefan
    Yaniv, Ziv
    MEDICAL IMAGING 2008: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, PTS 1 AND 2, 2008, 6918
  • [6] Reduction of motion blurring artifact using respiratory gated CT: A quantitative evaluation
    Lu, W
    Parikh, P
    Hubenschmidt, J
    Politte, D
    Whiting, B
    Bradley, J
    Low, D
    MEDICAL PHYSICS, 2005, 32 (06) : 2056 - 2056
  • [7] Evaluation of imaging performance of megavoltage cone-beam CT over an extended period
    Sumida, Iori
    Yamaguchi, Hajime
    Kizaki, Hisao
    Yamada, Yuji
    Koizumi, Masahiko
    Yoshioka, Yasuo
    Ogawa, Kazuhiko
    Kakimoto, Naoya
    Murakami, Shumei
    Furukawa, Souhei
    JOURNAL OF RADIATION RESEARCH, 2014, 55 (01) : 191 - 199
  • [8] Investigation of helix-saddle trajectories for cone-beam CT
    Lu, Yang
    Zhao, Jun
    Bai, Erwei
    Wang, Ge
    DEVELOPMENTS IN X-RAY TOMOGRAPHY VI, 2008, 7078
  • [9] Application of asymmetric cone-beam CT in radiotherapy
    Yu, LF
    Pelizzari, C
    Pan, XC
    Riem, H
    Munro, P
    Kaissl, W
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3249 - 3252
  • [10] RESPIRATORY MOTIONAL EFFECT ON CONE-BEAM CT IN LUNG RADIATION SURGERY
    Song, Ju-Young
    Nam, Taek-Keun
    Ahn, Sung-Ja
    Chung, Woong-Ki
    Yoon, Mee-Sun
    Nah, Byunk-Sik
    MEDICAL DOSIMETRY, 2009, 34 (02) : 117 - 125