Shear Elastic Modulus on Patellar Tendon Captured from Supersonic Shear Imaging: Correlation with Tangent Traction Modulus Computed from Material Testing System and Test-Retest Reliability
被引:100
作者:
Zhang, Zhi Jie
论文数: 0引用数: 0
h-index: 0
机构:
Hong Kong Polytech Univ, Dept Rehabil Sci, Kowloon, Peoples R China
Guangdong Prov Work Injury Rehabil Hosp, Dept Physiotherapy, Guangzhou, Guangdong, Peoples R ChinaHong Kong Polytech Univ, Dept Rehabil Sci, Kowloon, Peoples R China
Zhang, Zhi Jie
[1
,2
]
Fu, Siu Ngor
论文数: 0引用数: 0
h-index: 0
机构:
Hong Kong Polytech Univ, Dept Rehabil Sci, Kowloon, Peoples R ChinaHong Kong Polytech Univ, Dept Rehabil Sci, Kowloon, Peoples R China
Fu, Siu Ngor
[1
]
机构:
[1] Hong Kong Polytech Univ, Dept Rehabil Sci, Kowloon, Peoples R China
[2] Guangdong Prov Work Injury Rehabil Hosp, Dept Physiotherapy, Guangzhou, Guangdong, Peoples R China
来源:
PLOS ONE
|
2013年
/
8卷
/
06期
关键词:
MECHANICAL-PROPERTIES;
ELASTOGRAPHY;
STRENGTH;
D O I:
10.1371/journal.pone.0068216
中图分类号:
O [数理科学和化学];
P [天文学、地球科学];
Q [生物科学];
N [自然科学总论];
学科分类号:
07 ;
0710 ;
09 ;
摘要:
Characterization of the elastic properties of a tendon could enhance the diagnosis and treatment of tendon injuries. The purpose of this study was to examine the correlation between the shear elastic modulus on the patellar tendon captured from a Supersonic Shear Imaging (SSI) and the tangent traction modulus computed from a Material testing system (MTS) on 8 fresh patellar pig tendons (Experiment I). Test-retest reliability of the shear elastic modulus captured from the SSI was established in Experiment II on 22 patellar tendons of 11 healthy human subjects using the SSI. Spearman Correlation coefficients for the shear elastic modulus and tangent traction modulus ranged from 0.82 to 1.00 (all p<0.05) on the 8 tendons. The intra and inter-operator reliabilities were 0.98 (95% CI: 0.93-0.99) and 0.97 (95% CI: 0.93-0.98) respectively. The results from this study demonstrate that the shear elastic modulus of the patellar tendon measured by the SSI is related to the tangent traction modulus quantified by the MTS. The SSI shows good intra and inter-operator repeatability. Therefore, the present study shows that SSI can be used to assess elastic properties of a tendon.
机构:
Univ So Calif, Jacqueline Perry Musculoskeletal Biomech Res Lab, Div Biokinesiol & Phys Therapy, Los Angeles, CA USAUniv So Calif, Jacqueline Perry Musculoskeletal Biomech Res Lab, Div Biokinesiol & Phys Therapy, Los Angeles, CA USA
Arya, Shruti
;
Kulig, Kornelia
论文数: 0引用数: 0
h-index: 0
机构:
Univ So Calif, Jacqueline Perry Musculoskeletal Biomech Res Lab, Div Biokinesiol & Phys Therapy, Los Angeles, CA USAUniv So Calif, Jacqueline Perry Musculoskeletal Biomech Res Lab, Div Biokinesiol & Phys Therapy, Los Angeles, CA USA
机构:
Univ So Calif, Jacqueline Perry Musculoskeletal Biomech Res Lab, Div Biokinesiol & Phys Therapy, Los Angeles, CA USAUniv So Calif, Jacqueline Perry Musculoskeletal Biomech Res Lab, Div Biokinesiol & Phys Therapy, Los Angeles, CA USA
Arya, Shruti
;
Kulig, Kornelia
论文数: 0引用数: 0
h-index: 0
机构:
Univ So Calif, Jacqueline Perry Musculoskeletal Biomech Res Lab, Div Biokinesiol & Phys Therapy, Los Angeles, CA USAUniv So Calif, Jacqueline Perry Musculoskeletal Biomech Res Lab, Div Biokinesiol & Phys Therapy, Los Angeles, CA USA