Comparing feasibility of low-tube-voltage protocol with low-iodine-concentration contrast and high-tube-voltage protocol with high-iodine-concentration contrast in coronary computed tomography angiography

被引:14
作者
Cha, Min Jae [1 ,3 ]
Kim, Sung Mok [1 ,2 ]
Ahn, Tae Ran [1 ]
Choe, Yeon Hyeon [1 ,2 ]
机构
[1] Sungkyunkwan Univ, Dept Radiol, Samsung Med Ctr, Sch Med, Seoul, South Korea
[2] Sungkyunkwan Univ, Heart Vasc Stroke Inst, Imaging Ctr, Samsung Med Ctr,Sch Med, Seoul, South Korea
[3] Chung Ang Univ, Sch Med, Dept Radiol, Chung Ang Univ Hosp, Seoul, South Korea
来源
PLOS ONE | 2020年 / 15卷 / 07期
关键词
HYBRID ITERATIVE RECONSTRUCTION; IMAGE QUALITY; CT ANGIOGRAPHY; ISO-OSMOLAR; CONSPICUOUSNESS; IOMEPROL-400; ENHANCEMENT; IOPROMIDE; NOISE;
D O I
10.1371/journal.pone.0236108
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background To investigate the feasibility of a low tube voltage (80 kVp) protocol with low concentration contrast media (CM) (iodixanol 320 mgl/ml) as compared with a high tube voltage (100 kVp) protocol with high concentration CM (iomeprol 400 mgl/ml) in coronary CT angiography (CCTA) for patients with body mass index less than 30. Materials and methods A total of 93 patients were randomly assigned into three groups and underwent CCTA as follows: Group A) 100 kVp, 100-350 mAs, 400 mgl/ml CM at 4ml/s, and reconstructed with filtered back projection; Group B and C) 80 kVp, 100-450 mAs, 320 mgl/ml CM at 4 ml/s and 5 ml/s, respectively and reconstructed with iterative reconstruction. Objective and subjective image quality (IQ) was analyzed. Results The image noise, intravascular attenuation, signal-to-noise ratio and contrast-to-noise ratio of major coronary arteries did not differ significantly among three groups. Subjective IQ analyses on vascular attenuation and image noise did not differ significantly, either (all ofp> 0.05). Qualitative IQ of Group B and C was non-inferior to that of Group A. Substantial reduction of radiation exposure was achieved in group B (2.60 +/- 0.48 mSv) and C (2.72 +/- 0.54 mSv), compared with group A (3.58 +/- 0.67 mSv) (p< 0.05). Conclusion CCTA at 80 kVp with 320 mgl/ml CM and iterative reconstruction is feasible, achieving radiation dose reduction, while preserving IQ.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Adrenal and nephrogenic hypertension: an image quality study of low tube voltage, low-concentration contrast media combined with adaptive statistical iterative reconstruction
    Li, Zhen
    Li, Qiong
    Shen, Yaqi
    Li, Anqin
    Li, Haojie
    Liang, Lili
    Hu, Yao
    Hu, Xuemei
    Hu, Daoyu
    [J]. INTERNATIONAL JOURNAL OF CLINICAL PRACTICE, 2016, 70 (9B) : B29 - B36
  • [42] Contrast agent concentration optimization in CTA using low tube voltage and dual-energy CT in multiple vendors: a phantom study
    van Hamersvelt, Robbert W.
    Eijsvoogel, Nienke G.
    Mihl, Casper
    de Jong, Pim A.
    Schilham, Arnold M. R.
    Buls, Nico
    Das, Marco
    Leiner, Tim
    Willemink, Martin J.
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2018, 34 (08) : 1265 - 1275
  • [43] Contrast agent concentration optimization in CTA using low tube voltage and dual-energy CT in multiple vendors: a phantom study
    Robbert W. van Hamersvelt
    Nienke G. Eijsvoogel
    Casper Mihl
    Pim A. de Jong
    Arnold M. R. Schilham
    Nico Buls
    Marco Das
    Tim Leiner
    Martin J. Willemink
    [J]. The International Journal of Cardiovascular Imaging, 2018, 34 : 1265 - 1275
  • [44] Feasibility of Low-volume Injections of Contrast Material with a Body Weight-Adapted Iodine-Dose Protocol in 320-Detector Row Coronary CT Angiography
    Tatsugami, Fuminari
    Matsuki, Mitsuru
    Inada, Yuki
    Kanazawa, Shuji
    Nakai, Go
    Takeda, Yoshihiro
    Morita, Hideaki
    Takada, Haruhiko
    Ashida, Kenji
    Yoshikawa, Shushi
    Fukumura, Katsunori
    Narumi, Yoshifumi
    [J]. ACADEMIC RADIOLOGY, 2010, 17 (02) : 207 - 211
  • [45] High-Pitch Coronary CT Angiography at 70 kVp Adopting a Protocol of Low Injection Speed and Low Volume of Contrast Medium
    Feng, Ruiqi
    Tong, Jiajie
    Liu, Xiaofei
    Zhao, Yu
    Zhang, Liang
    [J]. KOREAN JOURNAL OF RADIOLOGY, 2017, 18 (05) : 763 - 772
  • [46] Non-enhanced Low-tube-voltage High-pitch Dual-source Computed Tomography with Sinogram Affirmed Iterative Reconstruction Algorithm of the Abdomen and Pelvis
    Hao Sun
    Hua-dan Xue
    Zheng-yu Jin
    Xuan Wang
    Yu Chen
    Yong-lan He
    Da-ming Zhang
    Liang Zhu
    [J]. ChineseMedicalSciencesJournal, 2014, 29 (04) : 214 - 220
  • [47] Low contrast- and low radiation dose protocol for cardiac CT of thin adults at 256-row CT: usefulness of low tube voltage scans and the hybrid iterative reconstruction algorithm
    Nakaura, Takeshi
    Kidoh, Masafumi
    Sakaino, Naritsugu
    Utsunomiya, Daisuke
    Oda, Seitaro
    Kawahara, Tetsuya
    Harada, Kazunori
    Yamashita, Yasuyuki
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 (04) : 913 - 923
  • [48] Evaluation of a Tube Voltage-Based Contrast Media Adaptation in Coronary Computed Tomography Angiography Using Personalized Triphasic Injection Protocols: A Matched Case-Control Study
    Gnasso, Chiara
    Vecsey-Nagy, Milan
    Schoepf, U. Joseph
    Stock, Jonathan
    Zsarnoczay, Emese
    Pinos, Daniel
    Tremamunno, Giuseppe
    Giovagnoli, Vincent
    Seidensticker, Peter
    Emrich, Tilman
    Varga-Szemes, Akos
    [J]. ACADEMIC RADIOLOGY, 2024, 31 (09) : 3570 - 3578
  • [49] Feasibility study of low tube voltage (80 kVp) coronary CT angiography combined with contrast medium reduction using iterative model reconstruction (IMR) on standard BMI patients
    Zhang, Fan
    Yang, Li
    Song, Xiang
    Li, Ying-Na
    Jiang, Yan
    Zhang, Xing-Hua
    Ju, Hai-Yue
    Wu, Jian
    Chang, Rui-Ping
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2016, 89 (1058)
  • [50] Diagnostic Accuracy of Pulmonary CT Angiography at Low Tube Voltage: Intraindividual Comparison of a Normal-Dose Protocol at 120 kVp and a Low-Dose Protocol at 80 kVp Using Reduced Amount of Contrast Medium in a Simulation Study
    Szucs-Farkas, Zsolt
    Schibler, Fabian
    Cullmann, Jennifer
    Torrente, Jaled Charimo
    Patak, Michael A.
    Raible, Stephan
    Hoppe, Hanno
    Wyttenbach, Rolf
    Vock, Peter
    Schindera, Sebastian T.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 197 (05) : W852 - W859