Comparing feasibility of low-tube-voltage protocol with low-iodine-concentration contrast and high-tube-voltage protocol with high-iodine-concentration contrast in coronary computed tomography angiography

被引:13
|
作者
Cha, Min Jae [1 ,3 ]
Kim, Sung Mok [1 ,2 ]
Ahn, Tae Ran [1 ]
Choe, Yeon Hyeon [1 ,2 ]
机构
[1] Sungkyunkwan Univ, Dept Radiol, Samsung Med Ctr, Sch Med, Seoul, South Korea
[2] Sungkyunkwan Univ, Heart Vasc Stroke Inst, Imaging Ctr, Samsung Med Ctr,Sch Med, Seoul, South Korea
[3] Chung Ang Univ, Sch Med, Dept Radiol, Chung Ang Univ Hosp, Seoul, South Korea
来源
PLOS ONE | 2020年 / 15卷 / 07期
关键词
HYBRID ITERATIVE RECONSTRUCTION; IMAGE QUALITY; CT ANGIOGRAPHY; ISO-OSMOLAR; CONSPICUOUSNESS; IOMEPROL-400; ENHANCEMENT; IOPROMIDE; NOISE;
D O I
10.1371/journal.pone.0236108
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background To investigate the feasibility of a low tube voltage (80 kVp) protocol with low concentration contrast media (CM) (iodixanol 320 mgl/ml) as compared with a high tube voltage (100 kVp) protocol with high concentration CM (iomeprol 400 mgl/ml) in coronary CT angiography (CCTA) for patients with body mass index less than 30. Materials and methods A total of 93 patients were randomly assigned into three groups and underwent CCTA as follows: Group A) 100 kVp, 100-350 mAs, 400 mgl/ml CM at 4ml/s, and reconstructed with filtered back projection; Group B and C) 80 kVp, 100-450 mAs, 320 mgl/ml CM at 4 ml/s and 5 ml/s, respectively and reconstructed with iterative reconstruction. Objective and subjective image quality (IQ) was analyzed. Results The image noise, intravascular attenuation, signal-to-noise ratio and contrast-to-noise ratio of major coronary arteries did not differ significantly among three groups. Subjective IQ analyses on vascular attenuation and image noise did not differ significantly, either (all ofp> 0.05). Qualitative IQ of Group B and C was non-inferior to that of Group A. Substantial reduction of radiation exposure was achieved in group B (2.60 +/- 0.48 mSv) and C (2.72 +/- 0.54 mSv), compared with group A (3.58 +/- 0.67 mSv) (p< 0.05). Conclusion CCTA at 80 kVp with 320 mgl/ml CM and iterative reconstruction is feasible, achieving radiation dose reduction, while preserving IQ.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Computed tomography portography of patients with cirrhosis with normal body mass index Comparison between low-tube-voltage CT with low contrast agent dose and conventional CT
    Liu, Sulan
    Sheng, Huaqiang
    Shi, Hao
    Li, Wei
    Fan, Jingli
    He, Jingzhen
    Sun, Hongjun
    MEDICINE, 2018, 97 (48)
  • [22] Low-Tube-Voltage CT Urography Using Low-Concentration-Iodine Contrast Media and Iterative Reconstruction: A Multi-Institutional Randomized Controlled Trial. for Comparison with Conventional. CT Urography
    Kim, Sang Youn
    Cho, Jeong Yeon
    Lee, Joongyub
    Hwang, Sung Il
    Moon, Min Hoan
    Lee, Eun Ju
    Hong, Seong Sook
    Kim, Chan Kyo
    Kim, Kyeong Ah
    Park, Sung Bin
    Sung, Deuk Jae
    Kim, Yongsoo
    Kim, You Me
    Jung, Sung Il
    Rha, Sung Eun
    Kim, Dong Won
    Lee, Hyun
    Shim, Youngsup
    Hwang, Inpyeong
    Woo, Sungmin
    Choi, Hyuck Jae
    KOREAN JOURNAL OF RADIOLOGY, 2018, 19 (06) : 1119 - 1129
  • [23] Coronary CT angiography by modifying tube voltage and contrast medium concentration: Evaluation of image quality and radiation dose
    Gazafroudi, Seyede Shokoofeh Mousavi
    Tavakkoli, Mohammad Bagher
    Moradi, Maryam
    Gazafroudi, Seyede Shabnam Mousavi
    Yadegarfar, Ghasem
    Behjati, Mohaddeseh
    Karimian, Mohammad
    Khajouei, Amirreza Sajjadieh
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2019, 36 (07): : 1391 - 1396
  • [24] Low-Contrast and Low-Radiation Dose Protocol in Cardiac Computed Tomography: Usefulness of Low Tube Voltage and Knowledge-Based Iterative Model Reconstruction Algorithm
    Iyama, Yuji
    Nakaura, Takeshi
    Yokoyama, Koichi
    Kidoh, Masafumi
    Harada, Kazunori
    Oda, Seitaro
    Tokuyasu, Shinichi
    Yamashita, Yasuyuki
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2016, 40 (06) : 941 - 947
  • [25] Application of low tube voltage coronary CT angiography with low-dose iodine contrast agent in patients with a BMI of 26-30 kg/m2
    Sun, G.
    Hou, Y. B.
    Zhang, B.
    Yu, L.
    Li, S. X.
    Tan, L. L.
    Chen, D. J.
    CLINICAL RADIOLOGY, 2015, 70 (02) : 138 - 145
  • [26] Application of Artificial Intelligence-based Image Optimization for Computed Tomography Angiography of the Aorta With Low Tube Voltage and Reduced Contrast Medium Volume
    Wang, Yining
    Yu, Min
    Wang, Ming
    Wang, Yun
    Kong, Lingyan
    Yi, Yan
    Wang, Man
    Li, Yumei
    Jin, Zhengyu
    JOURNAL OF THORACIC IMAGING, 2019, 34 (06) : 393 - 399
  • [27] Low tube voltage dual source computed tomography to reduce contrast media doses in adult abdomen examinations: A phantom study
    Thor, Daniel
    Brismar, Torkel B.
    Fischer, Michael A.
    MEDICAL PHYSICS, 2015, 42 (09) : 5100 - 5109
  • [28] Evaluation of a High Concentrated Contrast Media Injection Protocol in Combination with Low Tube Current for Dose Reduction in Coronary Computed Tomography Angiography: A Randomized, Two-center Prospective Study
    Sun, Yibo
    Hua, Yanqing
    Wang, Mingpeng
    Mao, Dingbiao
    Jin, Xiu
    Li, Cheng
    Shi, Kailei
    Xu, Jianrong
    ACADEMIC RADIOLOGY, 2017, 24 (12) : 1482 - 1490
  • [29] Diagnostic accuracy of low-radiation coronary computed tomography angiography with low tube voltage and knowledge-based model reconstruction
    Lee, Joohee
    Kim, Tae Hoon
    Lee, Byoung Kwon
    Yoon, Young Won
    Kwon, Hyuck Moon
    Hong, Bum Kee
    Min, Pil-Ki
    Choi, Eui-Young
    Oh, Chi Suk
    Park, Chul Hwan
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [30] Low kV and Low Concentration Contrast Agent with Iterative Reconstruction of Computed Tomography (CT) Coronary Angiography: A Preliminary Study
    Zhang, Hong
    Ma, Yanhe
    Lyu, Jun
    Yang, Yapeng
    Yuan, Wei
    Song, Zhenchun
    MEDICAL SCIENCE MONITOR, 2017, 23 : 5005 - 5010