Comparing feasibility of low-tube-voltage protocol with low-iodine-concentration contrast and high-tube-voltage protocol with high-iodine-concentration contrast in coronary computed tomography angiography

被引:16
作者
Cha, Min Jae [1 ,3 ]
Kim, Sung Mok [1 ,2 ]
Ahn, Tae Ran [1 ]
Choe, Yeon Hyeon [1 ,2 ]
机构
[1] Sungkyunkwan Univ, Dept Radiol, Samsung Med Ctr, Sch Med, Seoul, South Korea
[2] Sungkyunkwan Univ, Heart Vasc Stroke Inst, Imaging Ctr, Samsung Med Ctr,Sch Med, Seoul, South Korea
[3] Chung Ang Univ, Sch Med, Dept Radiol, Chung Ang Univ Hosp, Seoul, South Korea
关键词
HYBRID ITERATIVE RECONSTRUCTION; IMAGE QUALITY; CT ANGIOGRAPHY; ISO-OSMOLAR; CONSPICUOUSNESS; IOMEPROL-400; ENHANCEMENT; IOPROMIDE; NOISE;
D O I
10.1371/journal.pone.0236108
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background To investigate the feasibility of a low tube voltage (80 kVp) protocol with low concentration contrast media (CM) (iodixanol 320 mgl/ml) as compared with a high tube voltage (100 kVp) protocol with high concentration CM (iomeprol 400 mgl/ml) in coronary CT angiography (CCTA) for patients with body mass index less than 30. Materials and methods A total of 93 patients were randomly assigned into three groups and underwent CCTA as follows: Group A) 100 kVp, 100-350 mAs, 400 mgl/ml CM at 4ml/s, and reconstructed with filtered back projection; Group B and C) 80 kVp, 100-450 mAs, 320 mgl/ml CM at 4 ml/s and 5 ml/s, respectively and reconstructed with iterative reconstruction. Objective and subjective image quality (IQ) was analyzed. Results The image noise, intravascular attenuation, signal-to-noise ratio and contrast-to-noise ratio of major coronary arteries did not differ significantly among three groups. Subjective IQ analyses on vascular attenuation and image noise did not differ significantly, either (all ofp> 0.05). Qualitative IQ of Group B and C was non-inferior to that of Group A. Substantial reduction of radiation exposure was achieved in group B (2.60 +/- 0.48 mSv) and C (2.72 +/- 0.54 mSv), compared with group A (3.58 +/- 0.67 mSv) (p< 0.05). Conclusion CCTA at 80 kVp with 320 mgl/ml CM and iterative reconstruction is feasible, achieving radiation dose reduction, while preserving IQ.
引用
收藏
页数:10
相关论文
共 23 条
[1]   Comparative assessment of image quality for coronary CT angiography with iobitridol and two contrast agents with higher iodine concentrations: iopromide and iomeprol. A multicentre randomized double-blind trial [J].
Achenbach, Stephan ;
Paul, Jean-Francois ;
Laurent, Francois ;
Becker, Hans-Christoph ;
Rengo, Marco ;
Caudron, Jerome ;
Leschka, Sebastian ;
Vignaux, Olivier ;
Knobloch, Gesine ;
Benea, Giorgio ;
Schlosser, Thomas ;
Andreu, Jordi ;
Cabeza, Beatriz ;
Jacquier, Alexis ;
Souto, Miguel ;
Revel, Didier ;
Qanadli, Salah Dine ;
Cademartiri, Filippo .
EUROPEAN RADIOLOGY, 2017, 27 (02) :821-830
[2]   Coronary stent evaluation with coronary computed tomographic angiography: Comparison between low-osmolar, high-iodine concentration iomeprol-400 and iso-osmolar, lower-iodine concentration iodixanol-320 [J].
Andreini, Daniele ;
Pontone, Gianluca ;
Mushtaq, Saima ;
Bartorelli, Antonio L. ;
Conte, Edoardo ;
Bertella, Erika ;
Baggiano, Andrea ;
Annoni, Andrea ;
Formenti, Alberto ;
Ballerini, Giovanni ;
Agostoni, Piergiuseppe ;
Fiorentini, Cesare ;
Pepi, Mauro .
JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2014, 8 (01) :44-51
[3]   Low radiation dose in computed tomography: the role of iodine [J].
Aschoff, Andrik J. ;
Catalano, Carlo ;
Kirchin, Miles A. ;
Krix, Martin ;
Albrecht, Thomas .
BRITISH JOURNAL OF RADIOLOGY, 2017, 90 (1076)
[4]   Multicenter Comparison of High Concentration Contrast Agent Iomeprol-400 With Iso-osmolar Iodixanol-320 Contrast Enhancement and Heart Rate Variation in Coronary Dual-Source Computed Tomographic Angiography [J].
Becker, Cristoph R. ;
Vanzulli, Angelo ;
Fink, Christian ;
de Faveri, Daniele ;
Fedeli, Stefano ;
Dore, Roberto ;
Biondetti, Pietro ;
Kuettner, Alex ;
Krix, Martin ;
Ascenti, Giorgio .
INVESTIGATIVE RADIOLOGY, 2011, 46 (07) :457-464
[5]   Intraindividual comparison of contrast media concentrations for combined abdominal and thoracic MDCT [J].
Behrendt, Florian F. ;
Mahnken, Andreas H. ;
Stanzel, Sven ;
Seidensticker, Peter ;
Jost, Edgar ;
Guenther, Rolf W. ;
Muehlenbruch, Georg .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 191 (01) :145-150
[6]   Intravenous contrast material administration at helical 16-detector row CT coronary angiography: Effect of iodine concentration on vascular attenuation [J].
Cademartiri, F ;
Mollet, NR ;
van der Lugt, A ;
McFadden, EP ;
Stijnen, T ;
de Feyter, PJ ;
Krestin, GP .
RADIOLOGY, 2005, 236 (02) :661-665
[7]   High iodine concentration contrast material for noninvasive multislice computed tomography coronary angiography - Iopromide 370 versus iomeprol 400 [J].
Cademartiri, F ;
de Monye, C ;
Pugliese, F ;
Mollet, NR ;
Runza, G ;
van der Lugt, A ;
Midiri, M ;
de Feyter, PJ ;
Lagalla, R ;
Krestin, GP .
INVESTIGATIVE RADIOLOGY, 2006, 41 (03) :349-353
[8]   Knowledge-based iterative model reconstruction in coronary computed tomography angiography: comparison with hybrid iterative reconstruction and filtered back projection [J].
Cha, Min Jae ;
Seo, Jae Seung ;
Yoo, Dong Soo ;
Chong, Semin .
ACTA RADIOLOGICA, 2018, 59 (03) :280-286
[9]   Cerebral Computed Tomography Angiography Using a Low Tube Voltage (80 kVp) and a Moderate Concentration of Iodine Contrast Material A Quantitative and Qualitative Comparison With Conventional Computed Tomography Angiography [J].
Cho, Eun-Suk ;
Chung, Tae-Sub ;
Oh, Dae Kun ;
Choi, Hyun Seok ;
Suh, Sang Hyun ;
Lee, Hyeon-Kyeong ;
Lee, Kyung Hee .
INVESTIGATIVE RADIOLOGY, 2012, 47 (02) :142-147
[10]   Noise Reduction to Decrease Radiation Dose and Improve Conspicuity of Hepatic Lesions at Contrast-Enhanced 80-kV Hepatic CT Using Projection Space Denoising [J].
Ehman, Eric C. ;
Guimaraes, Luis S. ;
Fidler, Jeff L. ;
Takahashi, Naoki ;
Ramirez-Giraldo, Juan Carlos ;
Yu, Lifeng ;
Manduca, Armando ;
Huprich, James E. ;
McCollough, Cynthia H. ;
Holmes, David, III ;
Harmsen, W. Scott ;
Fletcher, Joel G. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (02) :405-411