Comparing feasibility of low-tube-voltage protocol with low-iodine-concentration contrast and high-tube-voltage protocol with high-iodine-concentration contrast in coronary computed tomography angiography

被引:13
|
作者
Cha, Min Jae [1 ,3 ]
Kim, Sung Mok [1 ,2 ]
Ahn, Tae Ran [1 ]
Choe, Yeon Hyeon [1 ,2 ]
机构
[1] Sungkyunkwan Univ, Dept Radiol, Samsung Med Ctr, Sch Med, Seoul, South Korea
[2] Sungkyunkwan Univ, Heart Vasc Stroke Inst, Imaging Ctr, Samsung Med Ctr,Sch Med, Seoul, South Korea
[3] Chung Ang Univ, Sch Med, Dept Radiol, Chung Ang Univ Hosp, Seoul, South Korea
来源
PLOS ONE | 2020年 / 15卷 / 07期
关键词
HYBRID ITERATIVE RECONSTRUCTION; IMAGE QUALITY; CT ANGIOGRAPHY; ISO-OSMOLAR; CONSPICUOUSNESS; IOMEPROL-400; ENHANCEMENT; IOPROMIDE; NOISE;
D O I
10.1371/journal.pone.0236108
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background To investigate the feasibility of a low tube voltage (80 kVp) protocol with low concentration contrast media (CM) (iodixanol 320 mgl/ml) as compared with a high tube voltage (100 kVp) protocol with high concentration CM (iomeprol 400 mgl/ml) in coronary CT angiography (CCTA) for patients with body mass index less than 30. Materials and methods A total of 93 patients were randomly assigned into three groups and underwent CCTA as follows: Group A) 100 kVp, 100-350 mAs, 400 mgl/ml CM at 4ml/s, and reconstructed with filtered back projection; Group B and C) 80 kVp, 100-450 mAs, 320 mgl/ml CM at 4 ml/s and 5 ml/s, respectively and reconstructed with iterative reconstruction. Objective and subjective image quality (IQ) was analyzed. Results The image noise, intravascular attenuation, signal-to-noise ratio and contrast-to-noise ratio of major coronary arteries did not differ significantly among three groups. Subjective IQ analyses on vascular attenuation and image noise did not differ significantly, either (all ofp> 0.05). Qualitative IQ of Group B and C was non-inferior to that of Group A. Substantial reduction of radiation exposure was achieved in group B (2.60 +/- 0.48 mSv) and C (2.72 +/- 0.54 mSv), compared with group A (3.58 +/- 0.67 mSv) (p< 0.05). Conclusion CCTA at 80 kVp with 320 mgl/ml CM and iterative reconstruction is feasible, achieving radiation dose reduction, while preserving IQ.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Use of pulmonary CT angiography with low tube voltage and low-iodine-concentration contrast agent to diagnose pulmonary embolism
    Hu, Xuemei
    Ma, Liya
    Zhang, Jinhua
    Li, Zhen
    Shen, Yaqi
    Hu, Daoyu
    SCIENTIFIC REPORTS, 2017, 7
  • [2] Low concentration contrast medium for dual-source computed tomography coronary angiography by a combination of iterative reconstruction and low-tube-voltage technique: Feasibility study
    Zheng, Minwen
    Liu, Ying
    Wei, Mengqi
    Wu, Yongjie
    Zhao, Hongliang
    Li, Jian
    EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (02) : E92 - E99
  • [3] Coronary Computed Tomographic Angiography at Low Concentration of Contrast Agent and Low Tube Voltage in Patients with Obesity: A Feasibility Study
    Pan, Yu-Ning
    Li, Ai-Jing
    Chen, Xiao-Min
    Wang, Jian
    Ren, Da -Wei
    Huang, Qiu-Li
    ACADEMIC RADIOLOGY, 2016, 23 (04) : 438 - 445
  • [4] Application of low-concentration contrast agents and low-tube-voltage computed tomography to chest enhancement examinations: A multicenter prospective study
    Meng, Donghua
    Cui, Xiaonan
    Bai, Changsen
    Yu, Zhongwen
    Xin, Lei
    Fu, Yufei
    Wang, Sicong
    Du, Yu
    Gao, Zhipeng
    Ye, Zhaoxiang
    SCIENCE PROGRESS, 2020, 103 (01)
  • [5] Cerebral Computed Tomography Angiography Using a Low Tube Voltage (80 kVp) and a Moderate Concentration of Iodine Contrast Material A Quantitative and Qualitative Comparison With Conventional Computed Tomography Angiography
    Cho, Eun-Suk
    Chung, Tae-Sub
    Oh, Dae Kun
    Choi, Hyun Seok
    Suh, Sang Hyun
    Lee, Hyeon-Kyeong
    Lee, Kyung Hee
    INVESTIGATIVE RADIOLOGY, 2012, 47 (02) : 142 - 147
  • [6] Personalized administration of contrast medium with high delivery rate in low tube voltage coronary computed tomography angiography
    Tan, Sock Keow
    Ng, Kwan Hoong
    Yeong, Chai Hong
    Aman, Raja Rizal Azman Raja
    Sani, Fadhli Mohamed
    Aziz, Yang Faridah Abdul
    Sun, Zhonghua
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2019, 9 (04) : 552 - +
  • [7] Whole-Body CT Angiography With Low Tube Voltage and Low-Concentration Contrast Material to Reduce Radiation Dose and Iodine Load
    Kanematsu, Masayuki
    Goshima, Satoshi
    Miyoshi, Toshiharu
    Kondo, Hiroshi
    Watanabe, Haruo
    Noda, Yoshifumi
    Bae, Kyongtae T.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2014, 202 (01) : W106 - W116
  • [8] Deep learning reconstruction algorithm and high-concentration contrast medium: feasibility of a double-low protocol in coronary computed tomography angiography
    Caruso, Damiano
    De Santis, Domenico
    Tremamunno, Giuseppe
    Santangeli, Curzio
    Polidori, Tiziano
    Bona, Giovanna G.
    Zerunian, Marta
    Del Gaudio, Antonella
    Pugliese, Luca
    Laghi, Andrea
    EUROPEAN RADIOLOGY, 2025, 35 (04) : 2213 - 2221
  • [9] Combination of a Low-Tube-Voltage Technique With Hybrid Iterative Reconstruction (iDose) Algorithm at Coronary Computed Tomographic Angiography
    Funama, Yoshinori
    Taguchi, Katsuyuki
    Utsunomiya, Daisuke
    Oda, Seitaro
    Yanaga, Yumi
    Yamashita, Yasuyuki
    Awai, Kazuo
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2011, 35 (04) : 480 - 485
  • [10] Diagnostic accuracy of low and high tube voltage coronary CT angiography using an X-ray tube potential-tailored contrast medium injection protocol
    Albrecht, Moritz H.
    Nance, John W.
    Schoepf, U. Joseph
    Jacobs, Brian E.
    Bayer, Richard R., II
    Litwin, Sheldon E.
    Reynolds, Michael A.
    Otani, Katharina
    Mangold, Stefanie
    Varga-Szemes, Akos
    De Santis, Domenico
    Eid, Marwen
    Apfaltrer, Georg
    Tesche, Christian
    Goeller, Markus
    Vogl, Thomas J.
    De Cecco, Carlo N.
    EUROPEAN RADIOLOGY, 2018, 28 (05) : 2134 - 2142