共 9 条
Association of arterial blood pressure and CPR quality in a child using three different compression techniques, a case report
被引:6
作者:
Sainio, Marko
[1
,2
]
Sutton, Robert M.
[3
]
Huhtala, Heini
[4
]
Eilevstjonn, Joar
[5
]
Tenhunen, Jyrki
[6
]
Olkkola, Klaus T.
[7
,8
]
Nadkarni, Vinay M.
[3
]
Hoppu, Sanna
[2
,9
,10
]
机构:
[1] Tampere Univ Hosp, Crit Care Med Res Grp, Dept Intens Care Med, FI-33521 Tampere, Finland
[2] Univ Tampere, FI-33521 Tampere, Finland
[3] Univ Penn, Childrens Hosp Philadelphia, Sch Med, Dept Anesthesiol Crit Care & Pediat, Philadelphia, PA 19104 USA
[4] Univ Tampere, Sch Hlth Sci, FI-33014 Tampere, Finland
[5] Laerdal Med AS, N-4002 Stavanger, Norway
[6] Uppsala Univ, Dept Surg Sci Anaesthesiol & Intens Care, SE-75185 Uppsala, Sweden
[7] Univ Turku, Dept Anaesthesiol Intens Care Emergency Care & Pa, FI-20521 Turku, Finland
[8] Turku Univ Hosp, FI-20521 Turku, Finland
[9] Tampere Univ Hosp, Dept Emergency Med, Dept Intens Care Med, FI-33521 Tampere, Finland
[10] Tampere Univ Hosp, Emergency Med Serv, Crit Care Med Res Grp, FI-33521 Tampere, Finland
关键词:
Cardiac Arrest;
Child;
Quality;
CPR;
CHEST COMPRESSIONS;
RESUSCITATION;
2-FINGER;
FEEDBACK;
2-THUMB;
D O I:
10.1186/1757-7241-21-51
中图分类号:
R4 [临床医学];
学科分类号:
1002 ;
100602 ;
摘要:
A 2-year-old boy found in cardiac arrest secondary to drowning received standard CPR for 35 minutes and was transported to a tertiary hospital for rewarming from hypothermia. Chest compressions in hospital were started using two-thumb encircling hands technique. Subsequently two-thumbs direct sternal compression technique and after sternal force/depth sensor placement, chest compression with classic one-hand technique were done. By using CPR recording/feedback defibrillator, quantitative CPR quality data and invasive arterial pressures were available for analyses for 5 hours and 35 minutes. 316 compressions with the two-thumb encircling hands technique provided a mean (SD) systolic arterial pressure (SAP) of 24 (4) mmHg, mean arterial pressure (MAP) 18 (3) and diastolic arterial pressure (DAP) of 15 (3) mmHg. similar to 6000 compressions with the two thumbs direct compression technique created a mean SAP of 45 (7) mmHg, MAP 35 (4) mmHg and DAP of 30 (3) mmHg. similar to 20,000 compressions with the sternal accelerometer in place produced SAP 50 (10) mmHg, MAP 32 (5) mmHg and DAP 24 (4) mmHg. Restoration of spontaneous circulation (ROSC) was achieved at the point when the child achieved normothermia by using peritoneal dialysis. Unfortunately, the child died ten hours after ROSC without any signs of neurological recovery. This case demonstrates improved hemodynamic parameters with classic one-handed technique with real-time quantitative quality of CPR feedback compared to either the two-thumbs encircling hands or two-thumbs direct sternal compression techniques. We speculate that the improved arterial pressures were related to improved chest compression depth when a real-time CPR recording/feedback device was deployed.
引用
收藏
页数:6
相关论文