Comparison of Point-to-Point and Multipoint Human Artery Pulse Wave Transit Time Measurement Algorithms

被引:2
作者
Stankus, A. [1 ]
Lukosius, Z.
Aponkus, D.
Andziulis, A.
Stankus, V. [2 ]
Kurmis, M. [3 ]
Locans, U. [4 ]
机构
[1] Klaipeda Univ, Dept Informat Engn, Mechatron Sci Inst, LT-91225 Klaipeda, Lithuania
[2] Kaunas Univ Technol, Dept Phys, LT-51368 Kaunas, Lithuania
[3] VU Inst Math & Informat, Dept Software Engn, LT-08663 Vilnius, Lithuania
[4] Ventspils Univ Coll, Ventspils, Latvia
关键词
D O I
10.5755/j01.eee.123.7.2384
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A. Stankus, Z. Lukosius, D. Aponkus, A. Andziulis, V. STankus, M. Kurmis, U. Locans. Comparison of Point-to-Point and Multipoint Human Artery Pulse Wave Transit Time Measurement Algorithms // Electronics and Electrical Engineering. - Kaunas : Technologija, 2012. - No. 7(123). - P. 95-98. The purpose of the study is to compare the accuracy of point-to-point measurement method of pulse wave propagation time from the multi-point. Electroimpedance method recorded pulse waves in the knees and ankles. Both the ECG signal and the digitized 16-bit analog-digital converter with a frequency of 1 kHz per channel. The study was conducted with 18 healthy volunteers, 20-22 years in the supine position for 3-4 minutes. With the help of LabVIEW tools created by the nine algorithms each subject were analyzed 250-300 pulse waves, highlighting the figure of the coefficient of variation. Their comparison showed that the analysis of pulse waves using different algorithms give different results. The most stable were made when times were measured between the highest peaks of the first derivatives of the forward pulse wave fronts. Similar results were found cross-correlation and cross-spectral analysis of second derivatives of the forward pulse wave fronts. It can be argued that the results of these algorithms allow the parameters obtained by averaging closer to the true results. III. 3, bibl. 8, tabl. 3 (in English; abstracts in English and Lithuanian).
引用
收藏
页码:95 / 98
页数:4
相关论文
共 8 条
[1]   ASSESSMENT OF ARTERIAL DISTENSIBILITY BY AUTOMATIC PULSE-WAVE VELOCITY-MEASUREMENT - VALIDATION AND CLINICAL-APPLICATION STUDIES [J].
ASMAR, R ;
BENETOS, A ;
TOPOUCHIAN, J ;
LAURENT, P ;
PANNIER, B ;
BRISAC, AM ;
TARGET, R ;
LEVY, BI .
HYPERTENSION, 1995, 26 (03) :485-490
[2]  
Bang S, 2009, BIOMED CIRC SYST C, P124
[3]  
Choi BC, 2004, IEEE IND ELEC, P3219
[4]   Measurement of pulse wave velocity using pulse wave Doppler ultrasound: Comparison with arterial tonometry [J].
Jiang, Benyu ;
Liu, Baoming ;
McNeill, Karen L. ;
Chowienczyk, Philip J. .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2008, 34 (03) :509-512
[5]  
Kazanavicius E., 2005, Information Technology and Control, V34, P29
[6]  
Narimatsu Kiyoyuki, 2001, Frontiers of Medical and Biological Engineering, V11, P45, DOI 10.1163/156855701750383187
[7]   Theoretical study on the effect of sensor contact force on pulse transit time [J].
Teng, Xiao-Fei ;
Zhang, Yuan-Ting .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2007, 54 (08) :1490-1498
[8]   Relationship between pulse transit time and blood pressure is impaired in patients with chronic heart failure [J].
Wagner, Daniel R. ;
Roesch, Norbert ;
Harpes, Patrick ;
Koertke, Heinrich ;
Plumer, Pierre ;
Saberin, Amir ;
Chakoutio, Viviane ;
Oundjede, Denis ;
Delagardelle, Charles ;
Beissel, Jean ;
Gilson, Georges ;
Kindermann, Ingrid ;
Boehm, Michael .
CLINICAL RESEARCH IN CARDIOLOGY, 2010, 99 (10) :657-664