Identification of peripheral vascular disease in elderly subjects using optical spectroscopy

被引:54
作者
McCully, KK
Landsberg, L
Suarez, M
Hofmann, M
Posner, JD
机构
[1] Department of Medicine, Allegheny University of the Health Sciences, Philadelphia
[2] Division of Geriatric and Rehabilitation Medicine, Allegheny University of the Health Sciences, Monroe Office Building, Philadelphia, PA 19131, City Ave. and Presidential Boulevard
来源
JOURNALS OF GERONTOLOGY SERIES A-BIOLOGICAL SCIENCES AND MEDICAL SCIENCES | 1997年 / 52卷 / 03期
关键词
D O I
10.1093/gerona/52A.3.B159
中图分类号
R592 [老年病学]; C [社会科学总论];
学科分类号
03 ; 0303 ; 100203 ;
摘要
The purpose of this study was to determine the usefulness of near-infrared spectroscopy (NIRS) measurements to identify peripheral vascular disease (PVD). Usefulness was determined by the frequency of a successful test, as well as comparison with standard clinical assessments. Study subjects (N = 117, mean age = 67.8 +/- 8.1 yrs) responded to a free screening for PVD. NIRS was used to measure the relative O-2 saturation of hemoglobin in the soleus muscle. The time to 1/2 recovery of O-2 saturation (O2T1/2) was measured after 1 minute of repeated plantar flexions using a Cybex Eagle seated calf machine. O2T1/2 was used as many subjects had recovery curves that did not have an exponential line shape. The test was done on both legs and the worst leg was used for analysis. For comparative purposes, a clinical history and physical examination were performed by a physician or nurse practitioner, which included questions on intermittent claudication, examination of peripheral pulses, and questions to identify cardiovascular risk factors. NIRS signals were obtained on 105 of 117 subjects (89% success rare). Subjects with body mass index (BMI) values above 32 appeared to have NIRS O2T1/2 values that were less reliable than subjects with BMI values less than or equal to 32 (77% success rate). The O2T1/2 was longer in subjects with claudication and reduced pulses than in subjects without these conditions. Sensitivity comparing O2T1/2 to claudication and reduced pulses varied from 51-76% and specificity from 65-80%, depending on the cutoff value for O2T1/2 that was used (normal value plus 1 or 2 SD). A longer O2T1/2 was significantly associated with incidence of diabetes, smoking, hypercholesterol, and coronary bypass surgery. In summary successful NIRS O2T1/2 measurements were made in 77% of the subjects, with failure primarily occurring in obese subjects. NIRS O2T1/2 measurements showed reasonable although not strong agreements with clinical assessments of PVD, and with some risk factors for cardiovascular disease.
引用
收藏
页码:B159 / B165
页数:7
相关论文
共 23 条
  • [1] ANKLE ARM BLOOD-PRESSURE INDEX - A USEFUL TEST FOR CLINICAL-PRACTICE
    APPLEGATE, WB
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1993, 270 (04): : 497 - 498
  • [2] OXYGEN-TRANSPORT TO EXERCISING LEG IN CHRONIC HYPOXIA
    BENDER, PR
    GROVES, BM
    MCCULLOUGH, RE
    MCCULLOUGH, RG
    HUANG, SY
    HAMILTON, AJ
    WAGNER, PD
    CYMERMAN, A
    REEVES, JT
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1988, 65 (06) : 2592 - 2597
  • [3] RECOVERY FROM EXERCISE-INDUCED DESATURATION IN THE QUADRICEPS MUSCLES OF ELITE COMPETITIVE ROWERS
    CHANCE, B
    DAIT, MT
    ZHANG, CD
    HAMAOKA, T
    HAGERMAN, F
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1992, 262 (03): : C766 - C775
  • [4] CHANCE B, 1989, NY ACAD SCI, V551, P1
  • [5] CHEATLE T, 1991, BRIT J SURG, V7, P405
  • [6] Comparison of muscle near-infrared spectroscopy and femoral blood gases during steady-state exercise in humans
    Costes, F
    Barthelemy, JC
    Feasson, L
    Busso, T
    Geyssant, A
    Denis, C
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1996, 80 (04) : 1345 - 1350
  • [7] NONINVASIVE MEASUREMENT OF FOREARM BLOOD-FLOW AND OXYGEN-CONSUMPTION BY NEAR-INFRARED SPECTROSCOPY
    DEBLASI, RA
    FERRARI, M
    NATALI, A
    CONTI, G
    MEGA, A
    GASPARETTO, A
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1994, 76 (03) : 1388 - 1393
  • [8] EDWARDS A, 1994, J APPL PHYSIOL, V75, P1884
  • [9] GAHTAN V, 1995, J VASC TECH, V19, P211
  • [10] GARDNER AW, 1992, MED SCI SPORT EXER, V24, P163