Elaboration of a reusable immunosensor for the detection of staphylococcal enterotoxin A (SEA) in milk with a quartz crystal microbalance

被引:40
|
作者
Salmain, Michele [1 ,2 ]
Ghasemi, Mahsa [1 ,2 ]
Boujday, Souhir [3 ,4 ]
Pradier, Claire-Marie [3 ,4 ]
机构
[1] Chim ParisTech, ENSCP, Lab Charles Friedel, F-75005 Paris, France
[2] CNRS, UMR 7223, F-75005 Paris, France
[3] Univ Paris 06, UPMC, Lab Reactivite Surface, F-75005 Paris, France
[4] CNRS, UMR 7197, F-75005 Paris, France
来源
关键词
Quartz crystal microbalance (QCM); Biosensor; Staphylococcal enterotoxin A; Protein A; Polyclonal antibody; Regeneration; PLASMON RESONANCE DETECTION; PROTEIN-A; PIEZOELECTRIC IMMUNOSENSOR; ANTIBODY IMMOBILIZATION; BIOSENSOR METHOD; IMMUNOASSAY; PURIFICATION; ADSORPTION; TOXINS; QCM;
D O I
10.1016/j.snb.2012.06.052
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An immunosensor with quartz crystal microbalance (QCM) detection operating in flow-through mode was set up for assaying staphylococcal enterotoxin A (SEA) in model buffer medium and in milk. This biosensor is label-free and operates in the direct format. Each step of construction of the sensing layer comprising the capture anti-SEA antibody was investigated at the molecular level and optimized. The molecular layer was built using either amine- or acid-terminated thiols, with and without adding protein A to immobilize anti-SEA. The most efficient strategy to immobilize the antibody was selected on the basis of the biosensor's response to a standard solution of SEA. The optimized sensing layer was successfully used for the direct and fast (15 min) assay of SEA in phosphate buffer by QCM within a working range of 0.05-1 mg L-1 and a limit of detection of 0.02 mg L-1. Using a sandwich type assay, the response was amplified by a factor of 2 and consequently the lowest measurable concentration dropped down to 0.007 mg L-1 for a total assay time of 25 min. Furthermore, sensor regeneration was achieved in good conditions with low pH buffer releasing solution. Two levels of regeneration were reached, the first one, up to the binding protein level, necessitating the rebinding of anti-SEA. In this case the response of the regenerated sensor was 73% in the first cycle then stabilized at 60% of the primary response. For the second level, the capture antibody was cross-linked to the underlayer of protein A and no further grafting was needed. In this second case, the response of the regenerated sensor was 65% of the primary response. Eventually, the piezoelectric immunosensor was successfully applied to the direct assay of SEA spiked in real milk samples. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:148 / 156
页数:9
相关论文
共 50 条
  • [41] High Fundamental Frequency Quartz Crystal Microbalance (HFF-QCMD) Immunosensor for detection of sulfathiazole in honey
    Cervera-Chiner, Lourdes
    Jimenez, Yolanda
    Montoya, Angel
    Juan-Borras, Marisol
    Pascual, Nuria
    Arnau, Antonio
    Escriche, Isabel
    FOOD CONTROL, 2020, 115
  • [42] High Fundamental Frequency Quartz Crystal Microbalance (HFF-QCM) immunosensor for pesticide detection in honey
    Cervera-Chiner, Lourdes
    Juan-Borras, Marisol
    March, Camen
    Arnau, Antonio
    Escriche, Isabel
    Montoya, Angel
    Jimenez, Yolanda
    FOOD CONTROL, 2018, 92 : 1 - 6
  • [43] Detection of bacterial contaminated milk by means of a quartz crystal microbalance based electronic nose
    Z. Ali
    W. T. O'Hare
    B. J. Theaker
    Journal of Thermal Analysis and Calorimetry, 2003, 71 : 155 - 161
  • [44] Detection of bacterial contaminated milk by means of a quartz crystal microbalance based electronic nose
    Ali, Z
    O'Hare, WT
    Theaker, BJ
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2003, 71 (01) : 155 - 161
  • [45] Quartz crystal microbalance biosensor for the detection of procalcitonin
    Pohanka, Miroslav
    TALANTA, 2023, 257
  • [46] DETECTION OF AFLATOXIN USING QUARTZ CRYSTAL MICROBALANCE
    Dulama, Ioana
    Popescu, Ion V.
    Cimpoca, Gh. Valerica
    Radulescu, Cristiana
    Gheboianu, Anca
    JOURNAL OF SCIENCE AND ARTS, 2010, (02): : 341 - 344
  • [47] Detection of protease activity on a quartz crystal microbalance
    Pollard, JD
    Evans, JA
    Denson, A
    Fawcett, N
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2003, 225 : U353 - U354
  • [48] Quartz Crystal Microbalance Biosensor for Ergotamine Detection
    Pohanka, Miroslav
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2020, 15 (05): : 4179 - 4187
  • [49] A reusable quartz crystal microbalance biosensor for highly specific detection of single-base DNA mutation
    Wang, Dingzhong
    Chen, Gengjia
    Wang, Huaming
    Tang, Wei
    Pan, Wei
    Li, Na
    Liu, Feng
    BIOSENSORS & BIOELECTRONICS, 2013, 48 : 276 - 280
  • [50] Direct-binding quartz crystal microbalance immunosensor to detect carp metallothionein
    Kim, N.
    Son, S. -H.
    Kim, C. -T.
    Cho, Y. -J.
    Kim, C. -J.
    Kim, W. Y.
    SENSORS AND ACTUATORS B-CHEMICAL, 2011, 157 (02) : 627 - 634