An immunosensor with quartz crystal microbalance (QCM) detection operating in flow-through mode was set up for assaying staphylococcal enterotoxin A (SEA) in model buffer medium and in milk. This biosensor is label-free and operates in the direct format. Each step of construction of the sensing layer comprising the capture anti-SEA antibody was investigated at the molecular level and optimized. The molecular layer was built using either amine- or acid-terminated thiols, with and without adding protein A to immobilize anti-SEA. The most efficient strategy to immobilize the antibody was selected on the basis of the biosensor's response to a standard solution of SEA. The optimized sensing layer was successfully used for the direct and fast (15 min) assay of SEA in phosphate buffer by QCM within a working range of 0.05-1 mg L-1 and a limit of detection of 0.02 mg L-1. Using a sandwich type assay, the response was amplified by a factor of 2 and consequently the lowest measurable concentration dropped down to 0.007 mg L-1 for a total assay time of 25 min. Furthermore, sensor regeneration was achieved in good conditions with low pH buffer releasing solution. Two levels of regeneration were reached, the first one, up to the binding protein level, necessitating the rebinding of anti-SEA. In this case the response of the regenerated sensor was 73% in the first cycle then stabilized at 60% of the primary response. For the second level, the capture antibody was cross-linked to the underlayer of protein A and no further grafting was needed. In this second case, the response of the regenerated sensor was 65% of the primary response. Eventually, the piezoelectric immunosensor was successfully applied to the direct assay of SEA spiked in real milk samples. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:148 / 156
页数:9
相关论文
共 50 条
  • [31] A Quartz Crystal Microbalance Immunosensor for Stem Cell Selection and Extraction
    Maglio, Ornella
    Costanzo, Salvatore
    Cercola, Rosaria
    Zambrano, Gerardo
    Mauro, Marco
    Battaglia, Raffaele
    Ferrini, Gianluca
    Nastri, Flavia
    Pavone, Vincenzo
    Lombardi, Angela
    SENSORS, 2017, 17 (12)
  • [32] Development of an amperometric immunosensor for detection of staphylococcal enterotoxin type A in cheese
    Ribeiro Pimenta-Martins, Maria Gardenny
    Furtado, Roselayne Ferro
    Dias Heneine, Luiz Guilherme
    Dias, Ricardo Souza
    Borges, Maria de Fatima
    Alves, Carlucio Roberto
    JOURNAL OF MICROBIOLOGICAL METHODS, 2012, 91 (01) : 138 - 143
  • [33] Explosives Detection in Sea Water with Phthalocyanine Quartz Crystal Microbalance Sensors
    Erbahar, Dilek D.
    Gurol, Ilke
    Ahsen, Vefa
    Ozturk, Zafer Ziya
    Musluoglu, Emel
    Harbeck, Mika
    SENSOR LETTERS, 2011, 9 (02) : 745 - 748
  • [34] Rapid Detection ofBifidobacterium bifidumin Feces Sample by Highly Sensitive Quartz Crystal Microbalance Immunosensor
    Hou, Kaijian
    Zhao, Pingsen
    Chen, Yongru
    Li, Guiping
    Lin, Yu
    Chen, Danjie
    Zhu, Dan
    Wu, Zezhen
    Lian, Danchun
    Huang, Xiaojun
    Li, Jilin
    FRONTIERS IN CHEMISTRY, 2020, 8
  • [35] Label-Free Detection of Gliadin in Food by Quartz Crystal Microbalance-Based Immunosensor
    Funari, Riccardo
    Terracciano, Irma
    Della Ventura, Bartolomeo
    Ricci, Sara
    Cardi, Teodoro
    D'Agostino, Nunzio
    Velotta, Raffaele
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2017, 65 (06) : 1281 - 1289
  • [36] Rapid Detection of Ovarian Cancer from Immunized Serum Using a Quartz Crystal Microbalance Immunosensor
    Chen, Yan
    Huang, Xian-He
    Shi, Hua-Shan
    Mu, Bo
    Lv, Qun
    ASIAN PACIFIC JOURNAL OF CANCER PREVENTION, 2012, 13 (07) : 3423 - 3426
  • [37] Reusable chromium-coated quartz crystal microbalance for immunosensing
    Oliver, M. J.
    Hernando-Garcia, J.
    Pobedinskas, P.
    Haenen, K.
    Rios, A.
    Sanchez-Rojas, J. L.
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2011, 88 (01) : 191 - 195
  • [38] Melamine-imprinted quartz crystal microbalance sensor for its detection in milk
    Tiwari, Mohit
    Pattanayek, Sudip K.
    JOURNAL OF APPLIED POLYMER SCIENCE, 2024, 141 (24)
  • [39] Multichannel Wireless-Electrodeless Quartz-Crystal Microbalance Immunosensor
    Ogi, Hirotsugu
    Nagai, Hironao
    Fukunishi, Yuji
    Yanagida, Taiji
    Hirao, Masahiko
    Nishiyama, Masayoshi
    ANALYTICAL CHEMISTRY, 2010, 82 (09) : 3957 - 3962
  • [40] Detection of staphylococcal enterotoxin in pasteurized milk with ELISA technique
    Küplülü, Ö
    Sarimehmetoglu, B
    Kaymaz, S
    TURKISH JOURNAL OF VETERINARY & ANIMAL SCIENCES, 2002, 26 (03): : 631 - 637