Elaboration of a reusable immunosensor for the detection of staphylococcal enterotoxin A (SEA) in milk with a quartz crystal microbalance

被引:40
|
作者
Salmain, Michele [1 ,2 ]
Ghasemi, Mahsa [1 ,2 ]
Boujday, Souhir [3 ,4 ]
Pradier, Claire-Marie [3 ,4 ]
机构
[1] Chim ParisTech, ENSCP, Lab Charles Friedel, F-75005 Paris, France
[2] CNRS, UMR 7223, F-75005 Paris, France
[3] Univ Paris 06, UPMC, Lab Reactivite Surface, F-75005 Paris, France
[4] CNRS, UMR 7197, F-75005 Paris, France
来源
关键词
Quartz crystal microbalance (QCM); Biosensor; Staphylococcal enterotoxin A; Protein A; Polyclonal antibody; Regeneration; PLASMON RESONANCE DETECTION; PROTEIN-A; PIEZOELECTRIC IMMUNOSENSOR; ANTIBODY IMMOBILIZATION; BIOSENSOR METHOD; IMMUNOASSAY; PURIFICATION; ADSORPTION; TOXINS; QCM;
D O I
10.1016/j.snb.2012.06.052
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An immunosensor with quartz crystal microbalance (QCM) detection operating in flow-through mode was set up for assaying staphylococcal enterotoxin A (SEA) in model buffer medium and in milk. This biosensor is label-free and operates in the direct format. Each step of construction of the sensing layer comprising the capture anti-SEA antibody was investigated at the molecular level and optimized. The molecular layer was built using either amine- or acid-terminated thiols, with and without adding protein A to immobilize anti-SEA. The most efficient strategy to immobilize the antibody was selected on the basis of the biosensor's response to a standard solution of SEA. The optimized sensing layer was successfully used for the direct and fast (15 min) assay of SEA in phosphate buffer by QCM within a working range of 0.05-1 mg L-1 and a limit of detection of 0.02 mg L-1. Using a sandwich type assay, the response was amplified by a factor of 2 and consequently the lowest measurable concentration dropped down to 0.007 mg L-1 for a total assay time of 25 min. Furthermore, sensor regeneration was achieved in good conditions with low pH buffer releasing solution. Two levels of regeneration were reached, the first one, up to the binding protein level, necessitating the rebinding of anti-SEA. In this case the response of the regenerated sensor was 73% in the first cycle then stabilized at 60% of the primary response. For the second level, the capture antibody was cross-linked to the underlayer of protein A and no further grafting was needed. In this second case, the response of the regenerated sensor was 65% of the primary response. Eventually, the piezoelectric immunosensor was successfully applied to the direct assay of SEA spiked in real milk samples. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:148 / 156
页数:9
相关论文
共 50 条
  • [1] Piezoelectric crystal immunosensor for the detection of staphylococcal enterotoxin B
    Lin, HC
    Tsai, WC
    BIOSENSORS & BIOELECTRONICS, 2003, 18 (12): : 1479 - 1483
  • [2] Human cytomegalovirus detection by a quartz crystal microbalance immunosensor
    Susmel, S
    O'Sullivan, CK
    Guilbault, GG
    ENZYME AND MICROBIAL TECHNOLOGY, 2000, 27 (09) : 639 - 645
  • [3] Detection of staphylococcal enterotoxin A (SEA) at picogram level by a capacitive immunosensor
    Jantra, Jongjit
    Kanatharana, Proespichaya
    Asawatreratanakul, Punnee
    Wongkittisuksa, Booncharoen
    Limsakul, Chusak
    Thavarungkul, Panote
    JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING, 2011, 46 (06): : 560 - 568
  • [4] Detection of Staphylococcal Enterotoxin B employing a piezoelectric crystal immunosensor
    Harteveld, JLN
    Nieuwenhuizen, MS
    Wils, ERJ
    BIOSENSORS & BIOELECTRONICS, 1997, 12 (07): : 661 - 667
  • [5] Quartz crystal microbalance immunosensor for the quantification of immunoglobulin G in bovine milk
    Crosson, Cyril
    Rossi, Claire
    BIOSENSORS & BIOELECTRONICS, 2013, 42 : 453 - 459
  • [6] Detection of Ebola glycoprotein using quartz crystal microbalance immunosensor
    Gerdon, Aren E.
    Huffman, Brian J.
    Wright, David W.
    Cliffel, David E.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2006, 231
  • [7] A novel electrochemical immunosensor based on magnetosomes for detection of staphylococcal enterotoxin B in milk
    Wu, Longyun
    Gao, Bo
    Zhang, Fang
    Sun, Xiulan
    Zhang, Yinzhi
    Li, Zaijun
    TALANTA, 2013, 106 : 360 - 366
  • [8] Immunosensor for the differentiation and detection of Salmonella species based on a quartz crystal microbalance
    Wong, YY
    Ng, SP
    Ng, MH
    Si, SH
    Yao, SZ
    Fung, YS
    BIOSENSORS & BIOELECTRONICS, 2002, 17 (08): : 676 - 684
  • [9] Development of a quartz crystal microbalance (QCM) immunosensor for the detection of Listeria monocytogenes
    Vaughan, RD
    O'Sullivan, CK
    Guilbault, GG
    ENZYME AND MICROBIAL TECHNOLOGY, 2001, 29 (10) : 635 - 638
  • [10] Immunosensor based on quartz crystal microbalance for schistosoma egg antigen detection
    Xu, Lijian
    He, Nongyue
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2013, 245