Red blood cells intended for transfusion:: quality criteria revisited

被引:65
作者
Högman, CF
Meryman, HT
机构
[1] Univ Hosp, Acad Lab, Div Clin Immunol & Transfus Med, Uppsala, Sweden
[2] Biomed Res Inst, Cryobiol Lab, Rockville, MD 20852 USA
关键词
D O I
10.1111/j.1537-2995.2006.00681.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Great variation exists with respect to viability and function of fresh and stored red blood cells (RBCs) as well as of the contents of RBC hemoglobin (Hb) in individual units. Improved technology is available for the preparation as well as the storage of RBCs. The authors raise the question whether it may be time to revise current standards for RBC units. The establishment of a standard unit of blood based on Hb content should be a high-priority goal. It is recommended that a standard RBC unit should contain 50 g of Hb. Major organizations concerned with the collection and distribution of blood components should agree on the criteria for a standard unit of RBCs based on Hb content and for the collection of double units. Manufacturers of blood collection equipment should provide suitable technology for collecting a standard unit with defined contents of RBC Hb. Efforts should be directed at the design of storage solutions acceptable for transfusion that maximize the maintenance of both RBC viability and function during storage. The ideal storage protocol would require sterile, high-pH solutions containing both glucose and electrolytes.
引用
收藏
页码:137 / 142
页数:6
相关论文
共 29 条
[11]   Storage of red blood cells: New approaches [J].
Hess, JR ;
Greenwalt, TG .
TRANSFUSION MEDICINE REVIEWS, 2002, 16 (04) :283-295
[12]   Storage parameters affecting red blood cell survival and function after transfusion [J].
Högman, CF ;
Meryman, HT .
TRANSFUSION MEDICINE REVIEWS, 1999, 13 (04) :275-296
[13]  
HOGMAN CF, 1993, VOX SANG, V65, P271
[14]   Standardized units of RBCs:: Is it time for implementation? [J].
Högman, CF ;
Knutson, F .
TRANSFUSION, 2000, 40 (03) :330-334
[15]  
HOGMAN CF, 1985, VOX SANG, V48, P257
[16]   Clinical and laboratory experience with erythrocyte and platelet preparations from a 0.5CPD Erythro-Sol opti system [J].
Hogman, CF ;
Eriksson, L ;
Wallvik, J ;
Payrat, JM .
VOX SANGUINIS, 1997, 73 (04) :212-219
[17]   Storage of whole blood before separation:: the effect of temperature on red cell 2,3 DPG and the accumulation of lactate [J].
Högman, CF ;
Knutson, F ;
Lööf, H .
TRANSFUSION, 1999, 39 (05) :492-497
[18]   Transfusion of red cells is associated with increased incidence of bacterial infection after colorectal surgery: A prospective study [J].
Houbiers, JG ;
vandeVelde, CJ ;
vandeWatering, LM ;
Hermans, J ;
Schreuder, S ;
Bijnen, AB ;
Pahlplatz, P ;
Schattenkerk, ME ;
Wobbes, T ;
deVries, JE ;
Klementschitsch, P ;
vandeMaas, AH ;
Brand, A .
TRANSFUSION, 1997, 37 (02) :126-134
[19]   CIRCULATION OF RED-BLOOD-CELLS HAVING HIGH-LEVELS OF 2,3-BISPHOSPHOGLYCERATE PROTECTS RAT-BRAIN FROM ISCHEMIC METABOLIC CHANGES DURING HEMODILUTION [J].
KIMURA, H ;
HAMASAKI, N ;
YAMAMOTO, M ;
TOMONAGA, M .
STROKE, 1995, 26 (08) :1431-1436
[20]   Toward an understanding of transfusion-related acute lung injury: statement of a consensus panel [J].
Kleinman, S ;
Caulfield, T ;
Chan, P ;
Davenport, R ;
McFarland, I ;
McPhedran, S ;
Meade, M ;
Morrison, D ;
Pinsent, T ;
Robillard, P ;
Slinger, P .
TRANSFUSION, 2004, 44 (12) :1774-1789