On the reliability of 3D gel dosimetry

被引:29
作者
De Deene, Y. [1 ,2 ]
Vandecasteele, J. [2 ]
机构
[1] Univ Sydney, Sch Phys, Inst Med Phys, Sydney, NSW 2006, Australia
[2] Univ Ghent Hosp, Expt Cancer Res, Dept Radiotherapy, B-9000 Ghent, Belgium
来源
7TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE) | 2013年 / 444卷
关键词
STATIC MAGNETIC-FIELD; RADIATION-DOSE DISTRIBUTIONS; EDDY-CURRENT FIELDS; POLYMER GEL; QUANTITATIVE CHARACTERIZATION; CONFORMAL RADIOTHERAPY; PAG DOSIMETERS; HUMAN HEAD; MRI; VERIFICATION;
D O I
10.1088/1742-6596/444/1/012015
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Gel dosimetry has a unique role to play in safeguarding conformal radiotherapy treatments as it covers the whole treatment chain and provides the radiation oncologist with the integrated dose distribution in 3D. A major obstacle that has hindered the wider dissemination of polymer gel dosimetry in radiotherapy centres is the lack of confidence in the reliability of the measured dose. Discrepancies in dose response of small versus large polymer gel dosimeters have been reported and although several hypothesis for these discrepancies have been postulated, the actual contribution of these error sources to the overall inaccuracy of the dose maps has not been determined. Several gel dosimetry research groups have chosen to use an internal calibration of gel dosimeters. In this study, the inter-and intra-batch reproducibility of the current state-of-the-art 3D gel dosimeters has been assessed. It is demonstrated that with a carefully designed scanning set-up, the overall accuracy that can be obtained with an independent calibration is well within 5% of all pixels.
引用
收藏
页数:30
相关论文
共 50 条
  • [21] Dosimetry Evolution in Teletherapy: Polimer Gel
    Hamann, J. H.
    Peixoto, J. G. P.
    9TH BRAZILIAN CONGRESS ON METROLOGY (METROLOGIA 2017), 2018, 975
  • [22] Semi- and virtual 3D dosimetry in clinical practice
    Korreman, S. S.
    7TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2013, 444
  • [23] 3D Polymer Gel Dosimeters with iCBCT 3D Reading and polyGeVero-CT Software Package for Quality Assurance in Radiotherapy
    Kozicki, Marek
    Maras, Piotr
    Jaszczak-Kuligowska, Malwina
    MATERIALS, 2024, 17 (06)
  • [24] On the measurement of radiation isocenter for medical accelerators using 3D polymer gel dosimetry. Introduction, application, and good practices
    Kozicki, Marek
    Maras, Piotr
    MEASUREMENT, 2023, 221
  • [25] 3D EPID-based in vivo dosimetry for IMRT and VMAT
    Mijnheer, B.
    Olaciregui-Ruiz, I.
    Rozendaal, R.
    Sonke, J-J
    Spreeuw, H.
    Tielenburg, R.
    van Herk, M.
    Vijlbrief, R.
    Mans, A.
    7TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2013, 444
  • [26] 3D evaluation of 3DVH program using BANG3 polymer gel dosimeter
    Watanabe, Yoichi
    Nakaguchi, Yuji
    MEDICAL PHYSICS, 2013, 40 (08)
  • [27] Gel dosimetry: An overview of dosimetry systems and read out methods
    De Deene, Yves
    Jirasek, Andrew
    RADIATION MEASUREMENTS, 2024, 179
  • [28] 3D Dosimetry based on a new optical approach for dosimetry gels: Use of the polarisation ratio of the scattering light
    Bleuse, O.
    Gschwind, R.
    Bailly, Y.
    Laurent, K.
    Bartova, H.
    Pilarova, K.
    Spevacek, V.
    Makovicka, L.
    9TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY, 2017, 847
  • [29] Introducing gel dosimetry in a clinical environment: Customization of polymer gel composition and magnetic resonance imaging parameters used for 3D dose verifications in radiosurgery and intensity modulated radiotherapy
    Crescenti, Remo A.
    Scheib, Stefan G.
    Schneider, Uwe
    Gianolini, Stefano
    MEDICAL PHYSICS, 2007, 34 (04) : 1286 - 1297
  • [30] Novel, full 3D scintillation dosimetry using a static plenoptic camera
    Goulet, Mathieu
    Rilling, Madison
    Gingras, Luc
    Beddar, Sam
    Beaulieu, Luc
    Archambault, Louis
    MEDICAL PHYSICS, 2014, 41 (08) : 449 - 461