On the reliability of 3D gel dosimetry

被引:29
|
作者
De Deene, Y. [1 ,2 ]
Vandecasteele, J. [2 ]
机构
[1] Univ Sydney, Sch Phys, Inst Med Phys, Sydney, NSW 2006, Australia
[2] Univ Ghent Hosp, Expt Cancer Res, Dept Radiotherapy, B-9000 Ghent, Belgium
来源
7TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE) | 2013年 / 444卷
关键词
STATIC MAGNETIC-FIELD; RADIATION-DOSE DISTRIBUTIONS; EDDY-CURRENT FIELDS; POLYMER GEL; QUANTITATIVE CHARACTERIZATION; CONFORMAL RADIOTHERAPY; PAG DOSIMETERS; HUMAN HEAD; MRI; VERIFICATION;
D O I
10.1088/1742-6596/444/1/012015
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Gel dosimetry has a unique role to play in safeguarding conformal radiotherapy treatments as it covers the whole treatment chain and provides the radiation oncologist with the integrated dose distribution in 3D. A major obstacle that has hindered the wider dissemination of polymer gel dosimetry in radiotherapy centres is the lack of confidence in the reliability of the measured dose. Discrepancies in dose response of small versus large polymer gel dosimeters have been reported and although several hypothesis for these discrepancies have been postulated, the actual contribution of these error sources to the overall inaccuracy of the dose maps has not been determined. Several gel dosimetry research groups have chosen to use an internal calibration of gel dosimeters. In this study, the inter-and intra-batch reproducibility of the current state-of-the-art 3D gel dosimeters has been assessed. It is demonstrated that with a carefully designed scanning set-up, the overall accuracy that can be obtained with an independent calibration is well within 5% of all pixels.
引用
收藏
页数:30
相关论文
共 50 条
  • [1] 3D Proton Gel Dosimetry
    Gorjiara, T.
    Kuncic, Z.
    Baldock, C.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [2] Uncertainty in 3D gel dosimetry
    De Deene, Yves
    Jirasek, Andrew
    8TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2015, 573
  • [3] Polymer gel 3D dosimetry in radiotherapy
    Pappas, Evangelos
    Maris, Thomas
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2020, 30 (03): : 171 - 172
  • [4] 3D gel Dosimetry of IMSRT using normoxic MAGAT polymer gel
    Beiki-Ardakani, A
    Heydarian, M
    Vitkin, A
    Kirilova, A
    Princess, DJA
    MEDICAL PHYSICS, 2005, 32 (06) : 1978 - 1979
  • [5] Optical Scanner for 3D Radiotherapy Polymer Gel Dosimetry
    Sobotka, P.
    Kozicki, M.
    Maras, P.
    Boniecki, L.
    Kacperski, K.
    Domanski, A. W.
    ACTA PHYSICA POLONICA A, 2012, 122 (05) : 969 - 974
  • [6] On the chemical stability of 3D monomer/polymer gel dosimetry
    De Deene, Y
    De Wagter, C
    Achten, E
    De Neve, W
    USE OF COMPUTERS IN RADIATION THERAPY, 2000, : 380 - 382
  • [7] 3D MAGIC gel dosimetry for verifying proton patch fields
    Shahnazi, K
    Cheng, I
    Moyers, M
    Luu, O
    Holshouser, B
    Loredo, L
    Slater, J
    Miller, D
    MEDICAL PHYSICS, 2003, 30 (06) : 1520 - 1520
  • [8] 3D POLYMER GEL DOSIMETRY FOR QUALITY ASSURANCE IN RADIATION THERAPY
    Ceberg, Sofie
    Adliene, Diana
    Mattsson, Soren
    MEDICAL PHYSICS IN THE BALTIC STATES, 2017, : 30 - 35
  • [9] 3D Slicer Gel Dosimetry Analysis: Validation of the Calibration Process
    Alexander, K. M.
    Pinter, C.
    Andrea, J.
    Fichtinger, G.
    Schreiner, L. J.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, 2015, VOLS 1 AND 2, 2015, 51 : 521 - 524
  • [10] Gel dosimetry by MRI using 3D gradient echo sequences
    Haacke, M
    Low, D
    Feng, L
    Herigault, G
    Islam, K
    Gurleyik, K
    MEDICAL PHYSICS, 2002, 29 (06) : 1206 - 1206