Development and comparison of two immunoassays for the detection of 2,4,6-trinitrotoluene (TNT) based on surface plasmon resonance

被引:48
作者
Shankaran, DR [1 ]
Matsumoto, K
Toko, K
Miura, N
机构
[1] Kyushu Univ, Art Sci & Technol Ctr Cooperat Res, Kasuga, Fukuoka 8168580, Japan
[2] Kyushu Univ, Venture Business Lab, Fukuoka 812, Japan
[3] Kyushu Univ, Grad Sch Agr, Fukuoka 8128581, Japan
[4] Kyushu Univ, Grad Sch Informat Sci & Elect Engn, Fukuoka 8128581, Japan
基金
日本科学技术振兴机构;
关键词
immunosensor; TNT; surface plasmon resonance; indirect competitive immunoreaction; landmine; anti-TNPh-KLH antibody; anti-TNP-BSA antibody;
D O I
10.1016/j.snb.2005.04.013
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper describes the development and comparison of two immunoassays for the detection of 2,4,6-trinitrotoluene (TNT) based on competitive inhibition. Two polyclonal antibodies were used in the immunoassay; one was prepared from 2,4,6-trinitrophenol-bovine serum albumin conjugate (anti-TNP-BSA Ab, goat IgG) and another from 2,4,6-trinitrophenyl-keyhole limpet hemocyanine conjugate (anti-TNPh-KLH Ab, rabbit IgG). A solid-phase immunoassay that consisted of physically immobilized TNP-BSA conjugate was allowed to interact with these antibodies and the resonance angle changes due to the biomolecular interactions were monitored by surface plasmon resonance (SPR). The quantification of TNT was based on the change in the resonance angle shift for binding of antibodies with a TNP-BSA conjugate, which occurred in the presence of TNT in solution. Both antibodies showed a high degree of affinity for TNT and varying degrees of cross-reactivity to the related nitroaromatic derivative compounds, such as 2,4-dinitrotoluene (DNT), 1,3-dinitrobenzene (DNB), 2-amino-4,6-dintitrotoluene (2A-4,6-DNT), 4-amino-2,6-dinitrotoluene (4A-2,6-DNT) and TNP. The anti-TNPh-KLH Ab prepared in our laboratory showed a detection limit of 0.006 ng/ml (6 ppt), which was comparable to or even better than the detection limit (0.095 ng/ml or 95 ppt) of a commercially available anti-TNP-BSA Ab for detection of TNT. A pepsin solution prepared with a glycine-HCl buffer (pH 2.0) was used for regeneration of the sensor surface. The duration for a single immunocycle was similar to 19 and similar to 13 min for anti-TNP-BSA Ab and anti-TNPh-KLH Ab immunosystems, respectively. The proposed immunoassay is simple and possesses good analytical characteristics for quantification of TNT. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:71 / 79
页数:9
相关论文
共 41 条
[1]   Immunochemical approaches for purification and detection of TNT traces by antibodies entrapped in a sol-gel matrix [J].
Altstein, M ;
Bronshtein, A ;
Glattstein, B ;
Zeichner, A ;
Tamiri, T ;
Almog, J .
ANALYTICAL CHEMISTRY, 2001, 73 (11) :2461-2467
[2]   Analysis of nitroaromatic compounds in urine by gas chromatography mass spectrometry for the biological monitoring of explosives [J].
Bader, M ;
Göen, T ;
Müller, J ;
Angerer, J .
JOURNAL OF CHROMATOGRAPHY B, 1998, 710 (1-2) :91-99
[3]   Current and emerging commercial optical biosensors [J].
Baird, CL ;
Myszka, DG .
JOURNAL OF MOLECULAR RECOGNITION, 2001, 14 (05) :261-268
[4]   Multi-analyte explosive detection using a fiber optic biosensor [J].
Bakaltcheva, IB ;
Ligler, FS ;
Patterson, CH ;
Shriver-Lake, LC .
ANALYTICA CHIMICA ACTA, 1999, 399 (1-2) :13-20
[5]  
Bilitewski U., 2000, Biosensors in Environmental Monitoring
[6]   Gas-phase detection of trinitrotoluene utilizing a solid-phase antibody immobilized on a gold film by means of surface plasmon resonance spectroscopy [J].
Bowen, J ;
Noe, LJ ;
Sullivan, BP ;
Morris, K ;
Martin, V ;
Donnelly, G .
APPLIED SPECTROSCOPY, 2003, 57 (08) :906-914
[7]   A novel aldehyde dextran sulfonate matrix for affinity biosensors [J].
Chegel, V ;
Shirshov, Y ;
Avilov, S ;
Demchenko, M ;
Mustafaev, M .
JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 2002, 50 (2-3) :201-216
[8]   Emerging biomedical sensing technologies and their applications [J].
Coté, GL ;
Lec, RM ;
Pishko, MV .
IEEE SENSORS JOURNAL, 2003, 3 (03) :251-266
[9]   Biosensors in clinical chemistry [J].
D'Orazio, P .
CLINICA CHIMICA ACTA, 2003, 334 (1-2) :41-69
[10]  
EMON JMV, 1998, J MICROBIOL METH, V32, P121