Maximum-likelihood estimation in Optical Coherence Tomography in the context of the tear film dynamics

被引:12
|
作者
Huang, Jinxin [1 ]
Clarkson, Eric [2 ]
Kupinski, Matthew [3 ]
Lee, Kye-sung [4 ,7 ]
Maki, Kara L. [5 ]
Ross, David S. [5 ]
Aquavella, James V. [6 ]
Rolland, Jannick P. [7 ]
机构
[1] Univ Rochester, Dept Phys & Astron, Rochester, NY 14627 USA
[2] Univ Arizona, Dept Radiol, Tucson, AZ 85720 USA
[3] Univ Arizona, Coll Opt Sci, Tucson, AZ 85720 USA
[4] Korea Basic Sci Inst, Ctr Analyt Instrumentat Dev, Taejon 305806, South Korea
[5] Rochester Inst Technol, Sch Math Sci, Rochester, NY 14623 USA
[6] Univ Rochester, Flaum Eye Inst, New York, NY 14642 USA
[7] Univ Rochester, Inst Opt, Rochester, NY 14627 USA
来源
BIOMEDICAL OPTICS EXPRESS | 2013年 / 4卷 / 10期
关键词
EYE DISEASE; SCATTERING; RESOLUTION; QUALITY;
D O I
10.1364/BOE.4.001806
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Understanding tear film dynamics is a prerequisite for advancing the management of Dry Eye Disease (DED). In this paper, we discuss the use of optical coherence tomography (OCT) and statistical decision theory to analyze the tear film dynamics of a digital phantom. We implement a maximum-likelihood (ML) estimator to interpret OCT data based on mathematical models of Fourier-Domain OCT and the tear film. With the methodology of task-based assessment, we quantify the tradeoffs among key imaging system parameters. We find, on the assumption that the broadband light source is characterized by circular Gaussian statistics, ML estimates of 40 nm +/- 4 nm for an axial resolution of 1 mu m and an integration time of 5 mu s. Finally, the estimator is validated with a digital phantom of tear film dynamics, which reveals estimates of nanometer precision. (C) 2013 Optical Society of America
引用
收藏
页码:1806 / 1816
页数:11
相关论文
共 23 条
  • [1] In vivo thickness dynamics measurement of tear film lipid and aqueous layers with optical coherence tomography and maximum-likelihood estimation
    Huang, Jinxin
    Hindman, Holly B.
    Rolland, Jannick P.
    OPTICS LETTERS, 2016, 41 (09) : 1981 - 1984
  • [2] Simultaneous Measurement of Tear Film Dynamics Using Wavefront Sensor and Optical Coherence Tomography
    Koh, Shizuka
    Tung, Cynthia
    Aquavella, James
    Yadav, Rahul
    Zavislan, James
    Yoon, Geunyoung
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (07) : 3441 - 3448
  • [3] Comparison of Kasai Autocorrelation and Maximum Likelihood Estimators for Doppler Optical Coherence Tomography
    Chan, Aaron C.
    Lam, Edmund Y.
    Srinivasan, Vivek J.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2013, 32 (06) : 1033 - 1042
  • [4] PERFORMANCE BREAKDOWN PREDICTION FOR MAXIMUM-LIKELIHOOD DOA ESTIMATION
    Abramovich, Yuri
    Johnson, Ben
    2010 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH, AND SIGNAL PROCESSING, 2010, : 2594 - 2597
  • [5] Simultaneous measurement of lipid and aqueous layers of tear film using optical coherence tomography and statistical decision theory
    Huang, Jinxin
    Clarkson, Eric
    Kupinski, Matthew
    Rolland, Jannick P.
    DESIGN AND QUALITY FOR BIOMEDICAL TECHNOLOGIES VII, 2014, 8936
  • [6] Efficient Maximum-Likelihood Estimation of Equivalent Number of Looks for PolSAR Image
    Qin, Xianxiang
    Zhang, Yanning
    Li, Ying
    IEEE GEOSCIENCE AND REMOTE SENSING LETTERS, 2023, 20
  • [7] Maximum-Likelihood Estimator for Coarse Carrier Frequency Offset Estimation in OFDM Systems
    Yang, Feng
    Zhang, Zhenrong
    Chen, Yifan
    WIRELESS PERSONAL COMMUNICATIONS, 2009, 49 (01) : 55 - 66
  • [8] Dynamics in cryo EM reconstructions visualized with maximum-likelihood derived variance maps
    Wang, Qiu
    Matsui, Tsutomu
    Domitrovic, Tatiana
    Zheng, Yili
    Doerschuk, Peter C.
    Johnson, John E.
    JOURNAL OF STRUCTURAL BIOLOGY, 2013, 181 (03) : 195 - 206
  • [9] Measurement of a multi-layered tear film phantom using optical coherence tomography and statistical decision theory
    Huang, Jinxin
    Yuan, Qun
    Zhang, Buyun
    Xu, Ke
    Tankam, Patrice
    Clarkson, Eric
    Kupinski, Matthew A.
    Hindman, Holly B.
    Aquavella, James V.
    Suleski, Thomas J.
    Rolland, Jannick P.
    BIOMEDICAL OPTICS EXPRESS, 2014, 5 (12): : 4374 - 4386
  • [10] Fast Industrial Inspection of Optical Thin Film Using Optical Coherence Tomography
    Shirazi, Muhammad Faizan
    Park, Kibeom
    Wijesinghe, Ruchire Eranga
    Jeong, Hyosang
    Han, Sangyeob
    Kim, Pilun
    Jeon, Mansik
    Kim, Jeehyun
    SENSORS, 2016, 16 (10)