Transthoracic echocardiography reference values in juvenile and adult 129/Sv mice

被引:29
|
作者
Vinhas, Mauricia [1 ]
Araujo, Ana Carolina [1 ,2 ]
Ribeiro, Sonia [3 ]
Rosario, Luis Bras [3 ]
Belo, Jose Antonio [1 ,2 ]
机构
[1] Univ Algarve UALG, Dept Biomed Sci & Med DCBM, Regenerat Med Program, P-8005139 Faro, Portugal
[2] Univ Algarve, Ctr Mol & Struct Biomed CBME, Inst Biotechnol & Bioengn, P-8005139 Faro, Portugal
[3] Hosp Santa Maria, Lisbon Acad Med Ctr CCUL, Serv Cardiol, Lisbon, Portugal
来源
CARDIOVASCULAR ULTRASOUND | 2013年 / 11卷
关键词
Echocardiography; Juvenile; Adult; 129/Sv mouse; Reference values; Doppler; LEFT-VENTRICULAR MASS; CARDIAC-FUNCTION;
D O I
10.1186/1476-7120-11-12
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: In the recent years, the use of Doppler-echocardiography has become a standard non-invasive technique in the analysis of cardiac malformations in genetically modified mice. Therefore, normal values have to be established for the most commonly used inbred strains in whose genetic background those mutations are generated. Here we provide reference values for transthoracic echocardiography measurements in juvenile (3 weeks) and adult (8 weeks) 129/Sv mice. Methods: Echocardiographic measurements were performed using B-mode, M-mode and Doppler-mode in 15 juvenile (3 weeks) and 15 adult (8 weeks) mice, during isoflurane anesthesia. M-mode measurements variability of left ventricle (LV) was determined. Results: Several echocardiographic measurements significantly differ between juvenile and adult mice. Most of these measurements are related with cardiac dimensions. All B-mode measurements were different between juveniles and adults (higher in the adults), except for fractional area change (FAC). Ejection fraction (EF) and fractional shortening (FS), calculated from M-mode parameters, do not differ between juvenile and adult mice. Stroke volume (SV) and cardiac output (CO) were significantly different between juvenile and adult mice. SV was 31.93 +/- 8.67 mu l in juveniles vs 70.61 +/- 24.66 mu l in adults, rho < 0.001. CO was 12.06 +/- 4.05 ml/min in juveniles vs 29.71 +/- 10.13 ml/min in adults, rho < 0.001. No difference was found in mitral valve (MV) and tricuspid valve (TV) related parameters between juvenile and adult mice. It was demonstrated that variability of M-mode measurements of LV is minimal. Conclusions: This study suggests that differences in cardiac dimensions, as wells as in pulmonary and aorta outflow parameters, were found between juvenile and adult mice. However, mitral and tricuspid inflow parameters seem to be similar between 3 weeks and 8 weeks mice. The reference values established in this study would contribute as a basis to future studies in post-natal cardiovascular development and diagnosing cardiovascular disorders in genetically modified mouse mutant lines.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Transthoracic echocardiography reference values in juvenile and adult 129/Sv mice
    Maurícia Vinhas
    Ana Carolina Araújo
    Sónia Ribeiro
    Luís Brás Rosário
    José António Belo
    Cardiovascular Ultrasound, 11
  • [2] Transthoracic echocardiography in Estrela Mountain dogs: Reference values for the breed
    Lobo, Luis
    Canada, Nuno
    Bussadori, Claudio
    Gomes, Joao Lopes
    Carvalheira, Julio
    VETERINARY JOURNAL, 2008, 177 (02): : 250 - 259
  • [3] Reference Values for Mid-Ascending Aorta Diameters by Transthoracic Echocardiography in Adults
    Ayoub, Chadi
    Kumar, Gautam
    Smith, Carin Y.
    Bryant, Sandra C.
    Jech, Diane M.
    Ionescu, Filip
    Petrescu, Ioana
    Miller, Fletcher A.
    Spittell, Peter C.
    AMERICAN JOURNAL OF CARDIOLOGY, 2018, 122 (06): : 1068 - 1073
  • [4] SELECTED COAGULATION REFERENCE VALUES FOR ADULT AND JUVENILE BABOONS
    KELLY, CA
    GLEISER, CA
    LABORATORY ANIMAL SCIENCE, 1986, 36 (02): : 173 - 175
  • [5] Reference intervals for transthoracic echocardiography in the American Staffordshire Terrier
    Vezzosi, Tommaso
    Ghinelli, Roberto
    Ferrari, Paolo
    Porciello, Francesco
    JOURNAL OF VETERINARY MEDICAL SCIENCE, 2021, 83 (04): : 656 - 660
  • [6] Age and gender related reference values for transthoracic Doppler-echocardiography in the anesthetized CD1 mouse
    Stypmann, Jorg
    Engelen, Markus A.
    Epping, Constanze
    van Rijen, Harold V. M.
    Milberg, Peter
    Bruch, Christian
    Breithardt, Guenter
    Tiemann, Klaus
    Eckardt, Lars
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2006, 22 (3-4): : 353 - 362
  • [7] Age and gender related reference values for transthoracic Doppler-echocardiography in the anesthetized CD1 mouse
    Jörg Stypmann
    Markus A. Engelen
    Constanze Epping
    Harold V.M. van Rijen
    Peter Milberg
    Christian Bruch
    Günter Breithardt
    Klaus Tiemann
    Lars Eckardt
    The International Journal of Cardiovascular Imaging, 2006, 22 : 353 - 362
  • [8] REFERENCE VALUES OF TRICUSPID ANNULUS SIZE AND DYNAMICS BY TWO-DIMENSIONAL TRANSTHORACIC ECHOCARDIOGRAPHY IN 220 HEALTHY VOLUNTEERS
    Miglioranza, Marcelo Haertel
    Muraru, Denisa
    Mihaila, Sorina
    Peluso, Diletta
    Cucchini, Umberto
    Casablanca, Simona
    Iliceto, Sabino
    Badano, Luigi
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (12) : A1987 - A1987
  • [9] HEMATOLOGIC AND SERUM CHEMICAL REFERENCE VALUES FOR ADULT AND JUVENILE BABOONS (PAPIO SP)
    HACK, CA
    GLEISER, CA
    LABORATORY ANIMAL SCIENCE, 1982, 32 (05): : 502 - 505
  • [10] Intraoperative Transthoracic Echocardiography for a Neonate Using an Adult Multiplane Transesophageal Echocardiography Probe
    Miura, Daisuke
    Yamada, Yasutaka
    Nakao, Misaki
    Sakaguchi, Yoshiro
    Mizuno, Keiichiro
    A & A PRACTICE, 2019, 12 (10): : 382 - 384