Nafion/Ni(OH)2 nanoparticles-carbon nanotube composite modified glassy carbon electrode as a sensor for simultaneous determination of dopamine and serotonin in the presence of ascorbic acid

被引:187
|
作者
Babaei, Ali [1 ,2 ]
Taheri, Ali Reza [1 ]
机构
[1] Arak Univ, Dept Chem, Arak 3815688349, Iran
[2] Arak Univ, Res Ctr Nanotechnol, Arak 3815688349, Iran
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2013年 / 176卷
关键词
Dopamine; Serotonin; Nafion; Ni(OH)(2) nanoparticles; Multiwalled carbon nanotubes; Modified glassy carbon; NICKEL-HYDROXIDE; ELECTROCHEMICAL PERFORMANCE; LIQUID-CHROMATOGRAPHY; GLUCOSE SENSOR; ION-EXCHANGE; FILM; BRAIN; VOLTAMMETRY; SELECTIVITY; BIOSENSOR;
D O I
10.1016/j.snb.2012.09.021
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The electrochemical oxidation of dopamine (DA) and serotonin (ST) have been investigated by application of Nafion/Ni(OH)(2)-multiwalled carbon nanotubes modified glassy carbon electrode (Nafion/Ni(OH)(2)-MWNTs/GCE) using cyclic voltammetry (CV), differential pulse voltammetry (DPV) and chronoamperometry (CA) methods. The modified electrode worked as an efficient electron-mediator for DA and ST in the presence of ascorbic acid (AA). Voltammetric techniques separated the anodic peaks of DA and ST, and the interference from AA was effectively excluded from DA and ST determination. The DPV data showed that the obtained anodic peak currents were linearly proportional to concentration in the range of 0.05-25 mu mol L-1 with a detection limit (S/N = 3.0) of 0.015 mu mol L-1 for DA and in the range of 0.008-10 mu mol L-1 and with a detection limit of 0.003 mu mol L-1 for ST. The proposed sensor was used for determination of ST and DA in human blood serum with satisfactory results. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:543 / 551
页数:9
相关论文
共 50 条
  • [31] Covalent modification of glassy carbon electrode with cysteine for the determination of dopamine in the presence of ascorbic acid
    Zhang, Lei
    MICROCHIMICA ACTA, 2008, 161 (1-2) : 191 - 200
  • [32] Fabrication of poly(orthanilic acid)-multiwalled carbon nanotubes composite film-modified glassy carbon electrode and its use for the simultaneous determination of uric acid and dopamine in the presence of ascorbic acid
    Zhang, Lei
    Shi, Zhige
    Lang, Qiuhua
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2011, 15 (04) : 801 - 809
  • [33] Simultaneous determination of dopamine and serotonin using a carbon nanotubes-ionic liquid gel modified glassy carbon electrode
    Sun, Yongxiang
    Fei, Junjie
    Hou, Jie
    Zhang, Qin
    Liu, Yanling
    Hu, Benan
    MICROCHIMICA ACTA, 2009, 165 (3-4) : 373 - 379
  • [34] Electrochemical sensor for the detection of dopamine in the presence of ascorbic acid in neutral pH on graphitized nanoporous carbon modified glassy carbon electrode
    Thangaraj, Rajendiran
    Mufeedah, Muringah Kandy
    Kumar, Annamalai Senthil
    RECENT TRENDS IN ADVANCED MATERIALS, 2012, 584 : 334 - 338
  • [35] Poly(3-thiophenemalonic acid) Modified Glassy Carbon Electrode for Selective Determination of Dopamine and Urine Acid in the Presence of Ascorbic Acid
    Wan, Jia
    Xu, Guang-Ri
    Liu, Zhangsuo
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (12): : 12955 - 12962
  • [36] Simultaneous determination of dopamine and serotonin on gold nanocluster/overoxidized-polypyrrole composite modified glassy carbon electrode
    Li, Jing
    Lin, Xiangqin
    SENSORS AND ACTUATORS B-CHEMICAL, 2007, 124 (02) : 486 - 493
  • [37] Fabrication of poly(orthanilic acid)–multiwalled carbon nanotubes composite film-modified glassy carbon electrode and its use for the simultaneous determination of uric acid and dopamine in the presence of ascorbic acid
    Lei Zhang
    Zhige Shi
    Qiuhua Lang
    Journal of Solid State Electrochemistry, 2011, 15 : 801 - 809
  • [38] Simultaneous determination of uric acid, dopamine and ascorbic acid based on poly(bromocresol green) modified glassy carbon electrode
    Ouyang, Xiaoqian
    Luo, Liqiang
    Ding, Yaping
    Liu, Bingdi
    Xu, Duo
    Huang, Anquan
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2015, 748 : 1 - 7
  • [39] Amperometric determination of ascorbic acid using multiwalled carbon nanotube-thiolated polyaniline composite modified glassy carbon electrode
    Liu, Ying
    Su, Zhaohong
    Zhang, Yi
    Chen, Li
    Gu, Tiean
    Huang, Siyu
    Liu, Yan
    Sun, Lingen
    Xie, Qingji
    Yao, Shouzhuo
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2013, 709 : 19 - 25
  • [40] Simultaneous determination of dopamine, ascorbic acid by polyethylene oxide (PEO) covalently modified glassy carbon electrode
    Gong, Wei
    Dou, Zhi-Yu
    Liu, Ping
    Cai, Xue-Ying
    He, Xing-quan
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2012, 666 : 62 - 66