In vivo electron spin resonance analysis of nitroxide radicals injected into a rat by a flexible surface-coil-type resonator as an endoscope- or a stethoscope-like device

被引:18
作者
Lin, YJ
Yokoyama, H
Ishida, S
Tsuchihashi, N
Ogata, T
机构
[1] YAMAGATA TECHNOPOLIS FDN,INST LIFE SUPPORT TECHNOL,YAMAGATA 990,JAPAN
[2] YAMAGATA UNIV,GRAD SCH ENGN,YONEZAWA,YAMAGATA,JAPAN
[3] IWAKI JOHBAN HOSP,IWAKI,FUKUSHIMA,JAPAN
[4] FUKUSHIMA MED COLL,FUKUSHIMA,JAPAN
关键词
in vivo ESR; nitroxide radical; surface-coil-type resonator; endoscope-like; stethoscope-like;
D O I
10.1007/BF02592239
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The flexible surface-coil-type resonator (FSCR) operating in a 700 MHz microwave electron spin resonance (ESR) system was applied to measure the nitroxide radicals at a specific area in rats. The FSCR was composed of a single-turn coil with a diameter of 5 mm and two flexible coaxial lines of 450 mm in length. For an endoscope-like application, the FSCR was inserted into the rectum of the rat and sequential changes in the ESR signals of the intravenously injected nitroxide radical (4-hydroxy-2,2,6,6-tetramethyl-piperidine-1-oxyl; TEMPOL or 3-carbamoyl-2,2,5,5-tetramethyl-pyrrolidine-1-yloxy; carbamoyl-PROXYL) were measured. The ESR signal intensity of the nitroxide decreased according to first-order kinetics. For a stethoscope-like application, the FSCR was placed at several sites on the abdominal skin of the rats receiving a subcutaneous injection of carbamoyl-PROXYL, and diffusion and/or metabolism of the radical in the skin was observed.
引用
收藏
页码:99 / 103
页数:5
相关论文
共 12 条
[1]  
EATON GR, 1991, EPR IMAGING IN VIVO
[2]   ANALYSIS OF A FLEXIBLE SURFACE-COIL-TYPE RESONATOR FOR MAGNETIC-RESONANCE MEASUREMENTS [J].
HIRATA, H ;
IWAI, H ;
ONO, M .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (09) :4529-4534
[3]   INVIVO ANALYSIS OF NITROXIDE RADICALS INJECTED INTO SMALL ANIMALS BY L-BAND ESR TECHNIQUE [J].
ISHIDA, S ;
KUMASHIRO, H ;
TSUCHIHASHI, N ;
OGATA, T ;
ONO, M ;
KAMADA, H ;
YOSHIDA, E .
PHYSICS IN MEDICINE AND BIOLOGY, 1989, 34 (09) :1317-1323
[4]  
ISHIDA S, 1992, MAGN RESON IMAGING, V10, P21
[5]   Dynamic electron spin resonance (ESR) imaging of the distribution of spin labeled dextran in a mouse [J].
Kazama, S ;
Takashige, G ;
Yoshioka, H ;
Tanizawa, H ;
Ogata, T ;
Koscielniak, J ;
Berliner, LJ .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (04) :547-550
[6]   HELICES AND SURFACE COILS FOR LOW-FIELD INVIVO ELECTRON-SPIN-RESONANCE AND ELECTRON-PARAMAGNETIC-RES IMAGING APPLICATIONS [J].
NISHIKAWA, H ;
FUJII, H ;
BERLINER, LJ .
JOURNAL OF MAGNETIC RESONANCE, 1985, 62 (01) :79-86
[7]   FIELD SCAN L-BAND ELECTRON-SPIN-RESONANCE COMPUTED-TOMOGRAPHY SYSTEM USING AN AIR-CORE ELECTROMAGNET [J].
OIKAWA, K ;
OGATA, T ;
LIN, YJ ;
SATO, T ;
KUDO, R ;
KAMADA, H .
ANALYTICAL SCIENCES, 1995, 11 (06) :885-888
[8]  
ONONO K, 1991, TRENDS PHYS CHEM, V2, P79
[9]   WHOLE RAT ELECTRON-PARAMAGNETIC RESONANCE IMAGING OF A NITROXIDE FREE-RADICAL BY A RADIO-FREQUENCY (280 MHZ) SPECTROMETER [J].
QUARESIMA, V ;
ALECCI, M ;
FERRARI, M ;
SOTGIU, A .
BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 1992, 183 (02) :829-835
[10]   A spatiotemporal study on the distribution of intraperitoneally injected nitroxide radical in the rat head using an in vivo ESR imaging system [J].
Yokoyama, H ;
Ogata, T ;
Tsuchihashi, N ;
Hiramatsu, M ;
Mori, N .
MAGNETIC RESONANCE IMAGING, 1996, 14 (05) :559-563