Preoperative Vascular Planning of Free Flaps: Comparative Study of Computed Tomographic Angiography, Color Doppler Ultrasonography, and Hand-Held Doppler

被引:31
作者
Gonzalez Martinez, Jesus
Torres Perez, Asia
Gijon Vega, Maria
Nunez-Villaveiran, Teresa
机构
[1] Hosp Clin Barcelona, Dept Plast & Reconstruct Surg, Barcelona, Spain
[2] Complejo Hosp Univ Albacete, Dept Plast & Reconstruct Surg, Albacete, Spain
关键词
ANTEROLATERAL THIGH FLAP; DUPLEX SONOGRAPHY; CT ANGIOGRAPHY; PERFORATOR; ULTRASOUND; EFFICACY; VESSELS; SURGERY;
D O I
10.1097/PRS.0000000000006966
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Preoperative planning of microsurgical perforator free flaps continues to be a discussion topic among microsurgeons. The purpose of this study was to compare the ability of three methods of preoperative vascular mapping-hand-held Doppler imaging, color Doppler ultrasonography, and computed tomographic angiography-to detect perforators and their concordance with surgical findings. Methods: A prospective study was performed to evaluate the sensitivity, specificity, and accuracy of hand-held Doppler imaging, color Doppler ultrasonography, and computed tomographic angiography to detect free flap perforators. Each patient undergoing a free flap reconstruction was studied preoperatively with the three methods, and the results were compared to the intraoperative findings. Results: Fifty-three patients undergoing autologous tissue reconstruction were included. Most reconstructions (71.7 percent) were performed with anterolateral thigh flaps. The positive predictive value (color Doppler ultrasonography, 100 percent; computed tomographic angiography, 100 percent; hand-held Doppler imaging, 88.6 percent) and negative predictive value (color Doppler ultrasonography, 100 percent; computed tomographic angiography, 94.3 percent; hand-held Doppler imaging, 90.5 percent) rates were significantly different between methods. The high resolution of the color Doppler ultrasonography probe provided a direct vision of the vasculature arborization and efficiently detected vessels with diameters of less than 0.5 mm. The sensitivity, specificity, and accuracy of color Doppler ultrasonography were greater than those of both computed tomographic angiography and hand-held Doppler imaging. There was 100 percent concordance between color Doppler ultrasonography perforators and the surgical findings. Conclusions: Color Doppler ultrasonography provides a reproducible, harmless, and accurate way to visualize vascular anatomy. It has a high correlation with the surgical findings, signifying advantages over hand-held Doppler and computed tomographic angiography in sensitivity, specificity, and accuracy.
引用
收藏
页码:227 / 237
页数:11
相关论文
共 38 条
  • [1] COLOR FLOW ULTRASOUND FOR DELINEATING MICROSURGICAL VESSELS - A CLINICAL AND EXPERIMENTAL-STUDY
    AMERHAUSER, A
    MOELLEKEN, BRW
    MATHES, SJ
    GOODING, G
    GOLDSTEIN, R
    CALLEN, P
    FILLY, RA
    MAY, JW
    [J]. ANNALS OF PLASTIC SURGERY, 1993, 30 (03) : 193 - 203
  • [2] Andrades C Patricio, 2014, Rev Chil Cir, V66, P134, DOI 10.4067/S0718-40262014000200007
  • [3] [Anonymous], 2011, HDB CRITICAL CARE EM
  • [4] Doppler flowmetry in the planning of perforator flaps
    Blondeel, PN
    Beyens, G
    Verhaeghe, R
    Van Landuyt, K
    Tonnard, P
    Monstrey, SJ
    Matton, G
    [J]. BRITISH JOURNAL OF PLASTIC SURGERY, 1998, 51 (03): : 202 - 209
  • [5] Planning Breast Reconstruction with Deep Inferior Epigastric Artery Perforating Vessels: Multidetector CT Angiography versus Color Doppler US
    Cina, Alessandro
    Salgarello, Marzia
    Barone-Adesi, Liliana
    Rinaldi, Pierluigi
    Bonomo, Lorenzo
    [J]. RADIOLOGY, 2010, 255 (03) : 979 - 987
  • [6] CORREA BERNAL DIANA MARÍA, 2012, rev.fac.med, V20, P42
  • [7] Colour duplex sonography and "Power-Duplex" in Perforator Surgery - Improvement of patients safety by efficient planning
    Daigeler, Adrien
    Schubert, Cornelius
    Hirsch, Tobias
    Behr, Bjoern
    Lehnhardt, Marcus
    [J]. HANDCHIRURGIE MIKROCHIRURGIE PLASTISCHE CHIRURGIE, 2018, 50 (02) : 101 - 110
  • [8] Reliability of Color Doppler Ultrasound Imaging for the Assessment of Anterolateral Thigh Flap Perforators: A Prospective Study of 30 Perforators
    Debelmas, Alexandre
    Camuzard, Olivier
    Aguilar, Paola
    Qassemyar, Quentin
    [J]. PLASTIC AND RECONSTRUCTIVE SURGERY, 2018, 141 (03) : 762 - 766
  • [9] The Value of Color Duplex Imaging for Planning and Performing a Free Anterolateral Thigh Perforator Flap
    Dorfman, David
    Pu, Lee L. Q.
    [J]. ANNALS OF PLASTIC SURGERY, 2014, 72 : S6 - S8
  • [10] The efficacy of color duplex sonography in preoperative assessment of anterolateral thigh flap
    Ensat, Florian
    Babl, Maria
    Conz, Christian
    Rueth, Markus-Johannes
    Greindl, Markus
    Fichtl, Bernhard
    Herzog, Gerhard
    Ussmueller, Juergen
    Spies, Marcus
    [J]. MICROSURGERY, 2012, 32 (08) : 605 - 610