Reconstruction of 4D deformed CT for moving anatomy

被引:8
作者
Docef, Alen [1 ]
Murphy, Martin J. [2 ]
机构
[1] Virginia Commonwealth Univ, Dept Elect Engn, Richmond, VA 23220 USA
[2] Virginia Commonwealth Univ, Dept Radiat Oncol, Richmond, VA 23220 USA
关键词
4DCT; Iterative CT reconstruction; Deformable image registration;
D O I
10.1007/s11548-008-0266-x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose To develop a 4DCT reconstruction technique that improves time resolution when the anatomy moves with respiration. Method A cone-beam CT (CBCT) scan is performed and a breathing signal is acquired. At the same time a set of simulated CBCT projections is created from a prior source CT deformed by a time-dependent parametric deformation model. The model parameters are iteratively adjusted until the simulated projections optimally resemble the acquired images. This concept was tested with three different simulated deformation scenarios approximating a moving lung tumor with rigid and elastic deformation and a 3D anatomical expansion/contraction. Results The known deformation was accurately reconstructed in all three scenarios. The method is reasonably robust to noise and contrast mismatch in the projections Conclusion Matching simulated to actual CBCT projections can adequately constrain a 4D model of breathing-induced motion that occurs during acquisition of the CBCT data.
引用
收藏
页码:591 / 598
页数:8
相关论文
共 12 条
[1]  
Ben-Israel A., 2003, GEN INVERSES THEORY, V15
[2]   Deformed CT reconstruction from limited projection data [J].
Docef, A ;
Murphy, MJ ;
Keall, PJ ;
Siebers, JV ;
Williamson, JF .
CARS 2005: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2005, 1281 :104-108
[3]   Respiration-correlated spiral CT: A method of measuring respiratory-induced anatomic motion for radiation treatment planning [J].
Ford, EC ;
Mageras, GS ;
Yorke, E ;
Ling, CC .
MEDICAL PHYSICS, 2003, 30 (01) :88-97
[4]   Acquiring 4D thoracic CT scans using a multislice helical method [J].
Keall, PJ ;
Starkschall, G ;
Shukla, H ;
Forster, KM ;
Ortiz, V ;
Stevens, CW ;
Vedam, SS ;
George, R ;
Guerrero, T ;
Mohan, R .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (10) :2053-2067
[5]   Fast parametric elastic image registration [J].
Kybic, J ;
Unser, M .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 2003, 12 (11) :1427-1442
[6]   A method for the reconstruction of four-dimensional synchronized CT scans acquired during free breathing [J].
Low, DA ;
Nystrom, M ;
Kalinin, E ;
Parikh, P ;
Dempsey, JF ;
Bradley, JD ;
Mutic, S ;
Wahab, SH ;
Islam, T ;
Christensen, G ;
Politte, DG ;
Whiting, BR .
MEDICAL PHYSICS, 2003, 30 (06) :1254-1263
[7]   Measurement of lung tumor motion using respiration-correlated CT [J].
Mageras, GS ;
Pevsner, A ;
Yorke, ED ;
Rosenzweig, KE ;
Ford, EC ;
Hertanto, A ;
Larson, SM ;
Lovelock, DM ;
Erdi, YE ;
Nehmeh, SA ;
Humm, JL ;
Ling, CC .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (03) :933-941
[8]  
More J. J., 1978, Proceedings of the Biennial Conference on numerical analysis, P105
[9]   Comparative performance of linear and nonlinear neural networks to predict irregular breathing [J].
Murphy, Martin J. ;
Dieterich, Sonja .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (22) :5903-5914
[10]   Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy [J].
Seppenwoolde, Y ;
Shirato, H ;
Kitamura, K ;
Shimizu, S ;
van Herk, M ;
Lebesque, JV ;
Miyasaka, K .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 53 (04) :822-834